Technical User Guide
DOL 26SCR PNP/NPN www.dol-sensors.com 3
DOL 26NPN
The sensor is protected against polarity errors, and the outputs are pro-
tected against overload and short circuit. If the output current exceeds the
nominal output current, the output function is switched off. Remove the short
circuit or choose a smaller load to remove the error. The current limitation
error is indicated on the sensor by double flashes followed by a pause.
LED indication DOL 26 SCR status DOL 26 PNP/NPN status
RED OFF Sensor output is OFF
RED slow flashing Sensor delay is active
RED double flashing Sensor load error (overcurrent protection is active)
MaxRunTimer is active (optional)
RED ON Sensor output is ON
GREEN OFF - No power to sensor
GREEN ON - Power to sensor
Adjustment
DOL 26 has trimmers with different functions depending on its type for adjustment.
4 Technical data
DOL 26SCR DOL 26PNP/NPN
Electrical
Supply voltage (Ue)
V AC/DC 20 - 280 -
V DC - 10 - 36
Frequency Hz 47 - 63 -
Max. ripple % - 10
Max. Current mA AC/DC 500 -
mA DC - 500
Inrush current A ˂ 2,5A @ 30 ms -
Direct connection to Ue
(current >> 500 mA) with-
out damage to the sensor
times ˃10
Min. ON current mA AC/DC
RMS
< 10 (Ue = 20 - 90) -
< 6 (Ue = 90 - 280) -
OFF current mA AC/DC
RMS
< 3 (Ue = 20 - 90) -
< 1 (Ue = 90 - 280) -
Voltage drop, output ON V AC/DC ˂ 6 -
V DC - ˂ 2.5
current consumption with-
out load
mA DC - ˂ 6
Specifications
Detection speed Hz ˂ 15 ˂ 100
Time delay, start-up ms 265 60
Time delay, ON* s ˂ 0.065 - 600 ˂0,010 - 600
Time delay, OFF* (ad-
justable)
s 0.1 - 600