Dorner 32MVA1122 Series User manual

For other service manuals visit our website at:
www.dornerconveyors.com/manuals-literature
851-953 Rev. A Record Conveyor Serial Number Here
Variable Speed
VFD Controllers
Installation, Maintenance, and Parts Manual

Dorner Mfg. Corp. 2 851-953 Rev. A
Variable Speed VFD Controllers
Table of Contents
Introduction ......................................................................... 2
Warnings −General Safety ................................................. 3
Product Description ............................................................. 4
Specifications ...................................................................... 4
Industrial Controllers ....................................................... 4
Sanitary Controllers ......................................................... 5
Torque Specifications ...................................................... 5
Installation ........................................................................... 6
Required Tools................................................................. 6
Determine Conveyor Type............................................... 6
Industrial Conveyors .................................................... 6
Sanitary Conveyors ...................................................... 6
Industrial Controller Mounting ........................................ 6
2200 and 3200 Conveyor Mounting............................. 6
Aluminum Stand Leg Mounting................................... 8
7200 and 7300 Series Controller Mounting ..................... 9
AquaGard® Sanitary Controller Mounting.................... 10
AquaPruf® Sanitary Controller Mounting ..................... 12
Wiring............................................................................. 13
Preventive Maintenance and Adjustment .......................... 14
Required Tools ............................................................... 14
Controller Setup ............................................................ 14
Notes .................................................................................. 15
Service Parts....................................................................... 16
Industrial VFD Controller .............................................. 16
Sanitary VFD Controller ................................................ 18
Return Policy...................................................................... 20
Introduction
Upon receipt of shipment:
• Compare shipment with packing slip. Contact factory
regarding discrepancies.
• Inspect packages for shipping damage. Contact carrier
regarding damage.
• Accessories may be shipped loose. See accessory instruc-
tions for installation.
Dorner’s Limited Warranty applies.
Dorner reserves the right to make changes at any time
without notice or obligation.
IMPORTANT
Some illustrations may show guards removed. Do NOT
operate equipment without guards.

851-953 Rev. A 3 Dorner Mfg. Corp.
Variable Speed VFD Controllers
Warnings −General Safety
A
WARNING
The safety alert symbol, black triangle with
white exclamation, is used to alert you to
potential personal injury hazards.
A
DANGER
Climbing, sitting, walking or riding on
conveyor will cause severe injury.
KEEP OFF CONVEYORS.
A
DANGER
DO NOT OPERATE CONVEYORS IN AN
EXPLOSIVE ENVIRONMENT.
A
WARNING
Controller must be properly grounded.
Failure to properly ground controller may
cause injury to personnel.
A
DANGER
Hazardous voltage will cause severe injury or
death.
LOCKOUT POWER BEFORE wiring.
A
WARNING
Exposed moving parts can cause severe
injury.
DO NOT ATTEMPT ADJUSTMENTS WITH
CONVEYOR RUNNING.
A
WARNING
Dorner cannot control the physical
installation and application of conveyors.
Taking protective measures is the
responsibility of the user.
When conveyors are used in conjunction
with other equipment or as part of a multiple
conveyor system, CHECK FOR POTENTIAL
PINCH POINTS and other mechanical
hazards before system start-up.

Dorner Mfg. Corp. 4 851-953 Rev. A
Variable Speed VFD Controllers
Product Description
Dorner Variable Speed VFD Controllers (Figure 1) are AC
motor speed controllers for Standard and Heavy Load VFD
gearmotors.
Figure 1
Figure 1
Illustration References:
Specifications
Industrial Controllers
4
5
6
3
1
2
NOTE
For additional information, refer to the
Invertek Drives Quick Start Guide shipped
with your controller.
1 Decrease Speed Button
2 Increase Speed Button
3 Display
4 Start Button
5 Stop Button
6 Enter Button
Model
Number Input Voltage
(VAC) & Phase
Input
Frequency
(Hz)
Output Voltage
(VAC) & Phase Max. HP
(kW)
Max.
Output
in Amps
32MVA1122(X) 115 Volts,
Single Phase 60 230 Volts,
Three Phase 0.5 (0.37) 2.3
32MVA2122(X) 230 Volts,
Single Phase 60 230 Volts,
Three Phase 0.5 (0.37) 2.3
32MVA2322(X) 230 Volts,
Three Phase 60 230 Volts,
Three Phase 0.5 (0.37) 2.3
32MVA4342(X) 460 Volts,
Three Phase 60 460 Volts,
Three Phase 0.5 (0.37) 1.2
32MVA1121(X) 115 Volts,
Single Phase 60 230 Volts,
Three Phase 1.0 (0.75) 5.8
32MVA2121(X) 230 Volts,
Single Phase 60 230 Volts,
Three Phase 1.0 (0.75) 4.3
32MVA2321(X) 230 Volts,
Three Phase 60 230 Volts,
Three Phase 1.0 (0.75) 4.3
32MVA4341(X) 460 Volts,
Three Phase 60 460 Volts,
Three Phase 1.0 (0.75) 2.2
32MVA2127(X) 230 Volts,
Single Phase 60 230 Volts,
Three Phase 2.0 (1.50) 7
32MVA2327(X) 230 Volts,
Three Phase 60 230 Volts,
Three Phase 2.0 (1.50) 7
32MVA4347(X) 460 Volts,
Three Phase 60 230 Volts,
Three Phase 2.0 (1.50) 5.8
(X): Blank = No Accessory Port; E = M12 Accessory Port Wired for End Stop Photo Eye Application;
I = M12 Accessory Port Wired for Indexing Photo Eye Application

851-953 Rev. A 5 Dorner Mfg. Corp.
Variable Speed VFD Controllers
Specifications
Sanitary Controllers
Torque Specifications
Model
Number Input Voltage
(VAC) & Phase
Input
Frequency
(Hz)
Output Voltage
(VAC) & Phase Max. HP
(kW)
Max.
Output
in Amps
76MVA1122S 115 Volts,
Single Phase 60 230 Volts,
Three Phase 0.5 (0.37) 2.3
76MVA2122S 230 Volts,
Single Phase 60 230 Volts,
Three Phase 0.5 (0.37) 2.3
76MVA2322S 230 Volts,
Three Phase 60 230 Volts,
Three Phase 0.5 (0.37) 2.3
76MVA4342S 460 Volts,
Three Phase 60 460 Volts,
Three Phase 0.5 (0.37) 1.2
76MVA1121S 115 Volts,
Single Phase 60 230 Volts,
Three Phase 1.0 (0.75) 5.8
76MVA2121S 230 Volts,
Single Phase 60 230 Volts,
Three Phase 1.0 (0.75) 4.3
76MVA2321S 230 Volts,
Three Phase 60 230 Volts,
Three Phase 1.0 (0.75) 4.3
76MVA4341S 460 Volts,
Three Phase 60 460 Volts,
Three Phase 1.0 (0.75) 2.2
76MVA2127S 230 Volts,
Single Phase 60 230 Volts,
Three Phase 2.0 (1.50) 7
76MVA2327S 230 Volts,
Three Phase 60 230 Volts,
Three Phase 2.0 (1.50) 7
76MVA4347S 460 Volts,
Three Phase 60 230 Volts,
Three Phase 2.0 (1.50) 5.8
NOTE
All Dorner OPTIDRIVE™ VFD’s are supplied
with an inline line filter to meet EN 61800-3 or
other EMC standards. Consult the safety
information section of the vendor manual.
Flat Head Socket Head Button/Low Head Set Screw
Size Torque Size Torque Size Torque Size Torque
M4 x 0.7 2.5 mm 3.4 Nm
(30 in lbs) 3 mm 5.9 Nm
(52 in lbs) 2.5 mm 2.9 Nm
(26 in lbs) 2 mm 2.1 Nm
(19 in lbs)
M5 x 0.8 3 mm 6.9 Nm
(61 in lbs) 4 mm 12.0 Nm
(106 in lbs) 3 mm 5.9 Nm
(52 in lbs) 2.5 mm 4.7 Nm
(42 in lbs)
M6 x 1.0 4 mm 12.0 Nm
(106 in lbs) 5 mm 20.3 Nm
(180 in lbs) 4 mm 10.0 Nm
(89 in lbs) 3 mm 7.7 Nm
(68 in lbs)
M8 x 1.25 5 mm 28.0 Nm
(248 in lbs) 6 mm 48.8 Nm
(432 in lbs) 5 mm 24.0 Nm
(212 in lbs) 4 mm 17.8 Nm
(158 in lbs)
M10 x 1.5 6 mm 56.0 Nm
(496 in lbs) 8 mm 97.5 Nm
(863 in lbs) 6 mm 48.0 Nm
(425 in lbs) 5 mm 35.0 Nm
(310 in lbs)

Dorner Mfg. Corp. 6 851-953 Rev. A
Variable Speed VFD Controllers
Installation
Required Tools
• 3 mm hex wrench
• 4 mm hex wrench
• 5 mm hex wrench
• 7 mm wrench
• 10 mm wrench
• 13 mm wrench
• 17 mm wrench
Determine Conveyor Type
Select the appropriate section based on your conveyor type:
Industrial Conveyors
• For 2200 and 3200 series conveyors, see “2200 and 3200
Conveyor Mounting” on page 6.
• For aluminum stand leg mounting, see “Aluminum Stand
Leg Mounting” on page 8.
Sanitary Conveyors
• For 7200 and 7300 series conveyors, see “7200 and 7300
Series Controller Mounting” on page 9.
• For AquaGard series conveyors, see “AquaGard® Sani-
tary Controller Mounting” on page 10.
• For AquaPruf series conveyors, see “AquaPruf® Sanitary
Controller Mounting” on page 12.
Industrial Controller Mounting
2200 and 3200 Conveyor Mounting
Installation Component List (Figure 2):
Figure 2
Figure 2
A
WARNING
Exposed moving parts can cause severe
injury.
LOCK OUT POWER before removing guards
or performing maintenance.
1VFDController
2 Mounting Rails (x2)
3 Drop-In Tee Bars (x4)
4 End Caps (x4)
5 Hex Nuts (x4)
6 Socket Head Screws (x4)
7 Socket Head Screws (x4)
1
3
2
4
5
6
7

851-953 Rev. A 7 Dorner Mfg. Corp.
Variable Speed VFD Controllers
Installation
1. Insert two hex nuts (Figure 3, item 1) into slot on each
mounting rail (Figure 3, item 2).
Figure 3
Figure 3
2. Insert end caps (Figure 4, item 1) into ends of mounting
rails (Figure 4, item 2).
Figure 4
Figure 4
3. Attach mounting bars (Figure 5, item 1) to controller
with screws (Figure 5, item 2).
Figure 5
Figure 5
4. Install drop-in tee bars (Figure 6, item 1) in 2200 Series
or 3200 Series conveyor T-slots.
Figure 6
Figure 6
5. Attach controller (Figure 7, item 1) to conveyor with
screws (Figure 7, item 2).
Figure 7
Figure 7
2
1
2
1
1
2
2
1
1
2

Dorner Mfg. Corp. 8 851-953 Rev. A
Variable Speed VFD Controllers
Installation
Aluminum Stand Leg Mounting
1. Install two drop-in tee bars (Figure 8, item 1) in stand
leg T−slots. Attach upper mounting rail (Figure
8, item 2) to stand (Figure 8, item 3) with two screws
(Figure 8, item 4).
Figure 8
Figure 8
2. Repeat step to install lower mounting rail (Figure
8, item 5).
3. Tighten four screws (Figure 9, item 1) until snug. Do
not fully tighten at this time.
Figure 9
Figure 9
4. Install two nuts (Figure 10, item 1) into slot in upper
mounting rail. Secure controller (Figure 10, item 2)
into stand leg T−slot with two washers (Figure
10, item 3) and screws (Figure 10, item 4).
Figure 10
Figure 10
5. Repeat step to secure controller to lower mounting rail.
6. Tighten four screws (Figure 11, item 1).
Figure 11
Figure 11
7. Fully tighten the four screws securing the upper and
lower mounting rails onto support stand, installed in
step 3.
5
3
1
2
4
1
1
3
4
2
1

851-953 Rev. A 9 Dorner Mfg. Corp.
Variable Speed VFD Controllers
Installation
8. Install end cap (Figure 12, item 1) onto each end of
mounting rail (Figure 12, item 2).
Figure 12
Figure 12
9. Repeat to install remaining end caps (Figure 13).
Figure 13
Figure 13
7200 and 7300 Series Controller
Mounting
Installation Component List (Figure 14):
Figure 14
Figure 14
1. Attach mounting plates (Figure 15, item 1) to controller
(Figure 15, item 2) with washers (Figure 15, item 3)
and screws (Figure 15, item 4).
Figure 15
Figure 15
A
WARNING
Exposed moving parts can cause severe
injury.
LOCK OUT POWER before removing guards
or performing maintenance.
1
2
1 Accessory Mounting Clips (2x)
(Shipped with gearmotor mount package)
2 Mounting Plate (2x)
3 VFD Controller
4 Hex Head Screws (4x)
5 Hex Head Screws (2x)
6 Washers (4x)
23
5
4
6
1
3
4
1
2

Dorner Mfg. Corp. 10 851-953 Rev. A
Variable Speed VFD Controllers
Installation
2. Loosely attach clips (Figure 16, item 1) to mounting
bar (Figure 16, item 2) with screws (Figure
16, item 3).
Figure 16
Figure 16
3. Attach controller (Figure 17, item 1) to conveyor
(Figure 17, item 2) with screws (Figure 17, item 3).
Figure 17
Figure 17
AquaGard® Sanitary Controller
Mounting
Installation Component List (Figure 18):
Figure 18
Figure 18
3
1
2
2
1
3
A
WARNING
Exposed moving parts can cause severe
injury.
LOCK OUT POWER before removing guards
or performing maintenance.
1 Controller Mount Plate
2 Mounting Plate (2x)
3 VFD Controller
4 Hex Head Screws (4x)
5 Washers (4x)
6 Hex Head Screws (2x)
7 Hex Head Screws (2x)
8 Washers (2x)
9 Carriage Bolts (2x)
10 Standoffs (2x)
11 Hex Nut (2x)
4
5
6
1
3
2
7
11
10
89

851-953 Rev. A 11 Dorner Mfg. Corp.
Variable Speed VFD Controllers
Installation
1. Attach mounting plates (Figure 19, item 1) to controller
(Figure 19, item 2) with washers (Figure 19, item 3)
and screws (Figure 19, item 4).
Figure 19
Figure 19
2. Attach controller mount plate (Figure 20, item 1) to
mounting plates (Figure 20, item 2) with screws
(Figure 20, item 3).
Figure 20
Figure 20
3. To install assembly to conveyor at stand location,
remove stand carriage bolts and replace with new
carriage bolts (Figure 21, item 1).
Figure 21
Figure 21
4. To install assembly to conveyor at frame connection,
remove screws and replace with new screws (Figure
22, item 1).
Figure 22
Figure 22
1
2
34
4
1
3
2
3
1
1

Dorner Mfg. Corp. 12 851-953 Rev. A
Variable Speed VFD Controllers
Installation
AquaPruf® Sanitary Controller
Mounting
Installation Component List (Figure 23):
Figure 23
Figure 23
1. Attach mounting plates (Figure 24, item 1) to controller
(Figure 24, item 2) with washers (Figure 24, item 3)
and screws (Figure 24, item 4).
Figure 24
Figure 24
2. Attach controller mount plate (Figure 25, item 1) to
mounting plates (Figure 25, item 2) with screws
(Figure 25, item 3).
Figure 25
Figure 25
3. Install assembly to conveyor at stand location by
removing screws and replacing with new screws
(Figure 26, item 1).
Figure 26
Figure 26
A
WARNING
Exposed moving parts can cause severe
injury.
LOCK OUT POWER before removing guards
or performing maintenance.
1 Controller Mount Plate
2 Mounting Plates (2x)
3 VFD Controller
4 Hex Head Screws (4x)
5 Washers (4x)
6 Hex Head Screws (2x)
7 Hex Head Screws (2x)
8 Standoffs (2x)
4
5
6
1
3
2
7
8
1
2
34
4
1
3
2
3
1

851-953 Rev. A 13 Dorner Mfg. Corp.
Variable Speed VFD Controllers
Installation
Wiring
1. Make the input power connections through the line
connection cord grip. Refer to the manufacturer’s
manual for terminations inside the VFD controller.
A
DANGER
Hazardous voltage will cause severe injury or
death.
LOCKOUT POWER BEFORE wiring.
A
WARNING
Exposed moving parts can cause severe
injury.
LOCK OUT POWER before removing guards
or performing maintenance.
A
WARNING
Controller must be properly grounded.
Failure to properly ground control box may
cause injury to personnel.
NOTE
A circuit breaker or a disconnect switch with
fuses must be provided in accordance with
the National Electrical Code (NEC) and all
local codes.
Refer to Lenze Installation and Operating
Manual shipped with your controller.
NOTE
For electrical wiring or troubleshooting, refer
to information provided by controller
manufacturer.

Dorner Mfg. Corp. 14 851-953 Rev. A
Variable Speed VFD Controllers
Preventive Maintenance and Adjustment
Required Tools
• Flat-blade screwdriver
Controller Setup
When purchased with a gearmotor, Dorner configures
Variable Speed VFD Controllers as follows:
• 1 second acceleration time
• 1 second deceleration time
• Minimum frequency @ 10 Hz for Sanitary units, 6 Hz for
Industrial units
• Maximum frequency @ 60 Hz
• Overloads set to motor Full Load Amperes (FLA)
A
DANGER
Hazardous voltage will cause severe injury or
death.
LOCKOUT POWER BEFORE wiring.
A
WARNING
Exposed moving parts can cause severe
injury.
LOCK OUT POWER before removing guards
or performing maintenance.
NOTE
For additional information or desired settings
other than listed, refer to the Invertek Drives
Quick Start Guide shipped with your
controller.

851-953 Rev. A 15 Dorner Mfg. Corp.
Variable Speed VFD Controllers
Notes

Dorner Mfg. Corp. 16 851-953 Rev. A
Variable Speed VFD Controllers
Service Parts
Industrial VFD Controller
NOTE
For replacement parts other than those shown in this section, contact an authorized Dorner distributor or
Dorner directly. Recommended Critical Service Parts and Kits are identified by the Key Service Parts
symbol . Dorner recommends keeping these parts on hand.
1
5
4
6
3
2
8
7

851-953 Rev. A 17 Dorner Mfg. Corp.
Variable Speed VFD Controllers
Service Parts
Item Part Number Description
1 805-2485 VFD Controller, 0.5 Hp, 115 Volts
Single Phase Input, 60Hz, 230 Volts,
Three Phase Output
805-2486 VFD Controller, 0.5 Hp, 230 Volts
Single Phase Input, 60Hz, 230 Volts,
Three Phase Output
805-2487 VFD Controller, 0.5 Hp, 230 Volts Three
Phase Input, 60Hz, 230 Volts, Three
Phase Output
805-2488 VFD Controller, 0.5 Hp, 460 Volts Three
Phase Input, 60Hz, 230 Volts, Three
Phase Output
805-2489 VFD Controller, 1.0 Hp, 115 Volts
Single Phase Input, 60Hz, 230 Volts,
Three Phase Output
805-2490 VFD Controller, 1.0 Hp, 230 Volts
Single Phase Input, 60Hz, 230 Volts,
Three Phase Output
805-2491 VFD Controller, 1.0 Hp, 230 Volts Three
Phase Input, 60Hz, 230 Volts, Three
Phase Output
805-2492 VFD Controller, 1.0 Hp, 460 Volts Three
Phase Input, 60Hz, 230 Volts, Three
Phase Output
805-2493 VFD Controller, 2.0 Hp, 230 Volts
Single Phase Input, 60Hz, 230 Volts,
Three Phase Output
805-2494 VFD Controller, 2.0 Hp, 230 Volts Three
Phase Input, 60Hz, 230 Volts, Three
Phase Output
805-2495 VFD Controller, 2.0 Hp, 460 Volts Three
Phase Input, 60Hz, 230 Volts, Three
Phase Output
2 205993 Mounting Rail
3 210849 Cap
4 202390M Drop-In Tee Bar
5 807-3003 Weld Nut
6 920512M Socket Head Screw, M5-.80 x 12 mm
7 911-512 Washer
8 920825M Socket Head Screw, M8-1.25 x 25 mm
Service parts can be obtained through your distributor or directly
from Dorner Mfg. Corp. (800) 397-8664 or
customerser[email protected]

Dorner Mfg. Corp. 18 851-953 Rev. A
Variable Speed VFD Controllers
Service Parts
Sanitary VFD Controller
1
5
4
6
3
2
7
8
9
10
11
12

851-953 Rev. A 19 Dorner Mfg. Corp.
Variable Speed VFD Controllers
Service Parts
Item Part Number Description
1 805-2485 VFD Controller, 0.5 Hp, 115 Volts
Single Phase Input, 60Hz, 230 Volts,
Three Phase Output
805-2486 VFD Controller, 0.5 Hp, 230 Volts
Single Phase Input, 60Hz, 230 Volts,
Three Phase Output
805-2487 VFD Controller, 0.5 Hp, 230 Volts Three
Phase Input, 60Hz, 230 Volts, Three
Phase Output
805-2488 VFD Controller, 0.5 Hp, 460 Volts Three
Phase Input, 60Hz, 230 Volts, Three
Phase Output
805-2489 VFD Controller, 1.0 Hp, 115 Volts
Single Phase Input, 60Hz, 230 Volts,
Three Phase Output
805-2490 VFD Controller, 1.0 Hp, 230 Volts
Single Phase Input, 60Hz, 230 Volts,
Three Phase Output
805-2491 VFD Controller, 1.0 Hp, 230 Volts Three
Phase Input, 60Hz, 230 Volts, Three
Phase Output
805-2492 VFD Controller, 1.0 Hp, 460 Volts Three
Phase Input, 60Hz, 230 Volts, Three
Phase Output
805-2493 VFD Controller, 2.0 Hp, 230 Volts
Single Phase Input, 60Hz, 230 Volts,
Three Phase Output
805-2494 VFD Controller, 2.0 Hp, 230 Volts Three
Phase Input, 60Hz, 230 Volts, Three
Phase Output
805-2495 VFD Controller, 2.0 Hp, 460 Volts Three
Phase Input, 60Hz, 230 Volts, Three
Phase Output
2 506344 Mounting Plate
3 960408MSS Hex Head Cap Screw, M4-0.70 x 8 mm
4 911-604 Washer, M4
5 520396 Controller Mount Plate
6 500693 Standoff
7 960612MSS Hex Head Cap Screw, M6-1.00 x 12
mm
8 961045MSS Hex Head Cap Screw, M10-1.5 x 45
mm for AquaPruf Conveyors Only
9 807-3600 Carriage Bolt, M8-1.25 x 45 mm for
AquaGard Conveyors Only
10 990801MSS Hex Nut for AquaGard Conveyors Only
11 807-1951 Washer, M8 for AquaGard Conveyors
Only
12 960845MSS Hex Head Cap Screw, M8-1.25 x 45
mm for AquaGard Conveyors Only
Service parts can be obtained through your distributor or directly
from Dorner Mfg. Corp. (800) 397-8664 or
customerser[email protected]

851-953 Rev. A
Return Policy
Returns must have prior written factory authorization or they will not be accepted. Items that are returned to Dorner without authorization will not
be credited nor returned to the original sender. When calling for authorization, please have the following information ready for the Dorner factory
representative or your local distributor:
1. Name and address of customer.
2. Dorner part number(s) of item(s) being returned.
3. Reason for return.
4. Customer's original order number used when ordering the item(s).
5. Dorner or distributor invoice number. Include part serial number if available.
A representative will discuss action to be taken on the returned items and provide a Returned Materials Authorization (RMA) number for
reference. RMA will automatically close 30 days after being issued. To get credit, items must be new and undamaged. There will be a return
charge on all items returned for credit, where Dorner was not at fault. It is the customer’s responsibility to prevent damage during return
shipping. Damaged or modified items will not be accepted. The customer is responsible for return freight.
Returns will not be accepted after 60 days from original invoice date. The return charge covers inspection, cleaning, disassembly, disposal and
reissuing of components to inventory. If a replacement is needed prior to evaluation of returned item, a purchase order must be issued. Credit (if
any) is issued only after return and evaluation is complete.
Dorner has representatives throughout the world. Contact Dorner for the name of your local representative. Our Customer Service Team will
gladly help with your questions on Dorner products.
For a copy of Dorner's Warranty, contact Dorner, an authorized sales channel or visit our website: www.dorner.com.
For replacement parts, contact an authorized Dorner Service Center or the factory.
Product Type
Standard Products Engineeredto
order parts
Product Line Conveyors Gearmotors
& Mounting
Packages
Support
Stands Accessories SpareParts
(non-belt) SpareBelts
- Standard
Flat Fabric
Spare Belts -
Cleated &
Spec. Fabric
Spare Belts -
Plastic Chain All equipment
and parts
1100 Series
30% return fee for all products except:
50% return fee for conveyors with modular belt,
cleated belt or speciality belts
All Electrical items are assigned original manufacturers return policy. non-returnable case-by-case
2200 Series
3200 Series
Pallet Systems
FlexMove/SmartFlex
GAL Series
All Electrical
7100 Series
50% return fee for all products
7200/7300 Series
AquaGard 7350
Series Version 2
GES Series
AquaGard
7350/7360 Series non-returnable
AquaPruf Series
This manual suits for next models
10
Table of contents
Other Dorner Controllers manuals