Dover MagLink LX4 Instruction sheet

ProGauge MagLink LX 4 and LX Plus
Configuration Manual
Part Number: M2051
Revision: 4
MagLink LX 4 and LX Plus

IMPORTANT: Before you use this manual, make sure you have the most recent revision.
Look at the revision of this document to make sure it agrees with the most current revision
found in the FMS Technical Library. Download the latest revision if necessary.
IMPORTANT: If you have an installation in an area that has possible internet connectivity
issues, it is recommended to either print or download these manuals to a mobile device
(mobile phone, tablet or iPad) before you go to the installation site.
READ CAREFULLY: OPW Fuel Management Systems and Dover Fueling Solutions cannot
be held responsible for installations, configurations or use of its products that does not comply
with the most recent documentation available.
NOTE: It will be necessary to have Single Sign-On (SSO) credentials to get access to
manuals, instructions, software updates and other important assets. Speak with your FMS
sales representative or contact FMS Customer Service at 1-888-679-3835 (1-888-OPW-
FUEL) for information. Once you have been approved for SSO credentials go to the FMS
Technical Library to find the most recent revisions of all manuals and instructions.
NOTE: All references to other manuals and instructions in this manual can be found in the
FMS Technical Library. Make sure you have the most recent revision.
Related Manuals
Other related manuals necessary to install, configure, maintain or use this product:
M2050 LX 4 Installation Manual
M2050-PLUS LX Plus Installation Manual
M2051 LX 4 and LX Plus Configuration Manual
M2052 LX 4 and LX Plus User Manual
M2054-QS LX 4 and LX Plus Quick Start
FMM2058-PLS LX Plus Wiring Diagram
FMM2058-PG LX Plus Wiring With ProGauge
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 2

ProGauge is a part of Dover Fueling Solutions.
Contact
START ITALIANA S.r.l.
Via Natta 6
20823 Lentate Sul Seveso
MB, Italy
Tel. +39 0362 1581465
Fax +39 0362 1581464
Copyright Information
© 2020 Dover Fueling Solutions. All rights reserved. DOVER, the DOVER D Design, DOVER FUELING
SOLUTIONS, and other trademarks referenced herein are trademarks of Delaware Capital Formation.
Inc./Dover Corporation, Dover Fueling Solutions UK Ltd. and their affiliated entities.
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 3

Table of Contents
Section 1 Preface 7
Section 2 General Warnings 8
Section 3 Introduction 10
3.1 Safety Warnings 12
3.2 Information Panels 12
Section 4 Direct Connection 14
Section 5 Login Procedure 17
Section 6 Admin Account 20
6.1 System Settings 21
6.1.1 Site Info 21
6.1.2 System 22
6.1.3 Protocols 24
6.1.4 Tank Group 25
6.1.5 Shifts 26
6.1.6 Fairbanks 27
6.1.7 SMTP 28
6.1.8 Site Mapping (for Reconciliation/Autocalibration mode only) 29
6.1.8.1 Map Dispensers and Nozzles to Tanks 30
6.1.9 IFSF 30
6.2 Notifications Menu 31
6.2.1 Contacts 31
6.2.2 Notifications 32
6.3 Tank Setup Menu 33
6.3.1 Settings 33
6.3.2 Thresholds 36
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 4

6.3.3 Density 38
6.3.4 AEF (Aqueous Ethanol Float) Thresholds 39
6.3.4.1 For Progauge Probes with AEF 39
6.3.4.2 For OPW 924B Probes with AEF 40
6.3.5 Relays 42
6.3.6 Straptable 43
6.3.7 Leak Test 45
6.3.7.1 Leak Test Setup 46
6.3.7.2 On-demand Test 47
6.3.8 ACR mode 48
6.3.8.1 ACR Configuration Parameters 48
6.3.8.2 Calibration Parameters 48
6.3.9 ACR Results 49
6.3.10 Reconciliation 50
Section 7 Sensor Setup 51
7.1 ProGauge Sensors 51
7.1.1 OPW FMS smart sensors (model LX Plus only). 52
7.2 Relays 53
Section 8 Tank Status 56
Section 9 Sensor Status 60
Section 10 Tank Group Status 61
Section 11 Reports Menu 62
11.1 History 63
11.2 Tank Alarms 63
11.3 Sensor Alarms 64
11.4 Line Alarms 64
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 5

11.5 Delivery 65
11.6 Tank Leak Tests 66
11.7 Line Leak Tests 67
11.8 Compliance 68
11.8.1 Sensor Compliance Report 68
11.8.2 Line Compliance Report 68
11.9 Sales 69
11.10 Shifts 70
11.11 Reconciliation 70
11.12 Configuration 73
Section 12 Maintenance 74
12.1 Manuals 74
12.2 Timezone 74
12.3 Network Configuration 75
12.4 Utility 75
12.5 Diagnostic (for LX Plus Only) 77
12.6 Console Settings 77
Section 13 Change Password 79
Section 14 Logout 80
Section 15 Guest Account 81
Section 16 Technical Support 82
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 6

Section 1 Preface
Start Italiana S.r.l. has made every effort possible to see that this document is complete, accurate and
updated. With every revision of the console, the related information is added to the document. Start Italiana
S.r.l. reserves the right to make unannounced improvements and/or changes in the product and/or
associated programs. Start Italiana S.r.l. is not liable for damages of any kind, including those resulting in the
document, including typographical errors.
Making copies, citing quotes or other reproductions of all or part of this document is permitted only after
written consent of Start Italiana S.r.l.
Patents protect trademark or name.
Copyright 2022© Start Italiana S.r.l. – All rights reserved
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 7

Section 2 General Warnings
Carefully read the instructions in this manual before you do the installation procedures.
Only approved persons are permitted to install this equipment and configure the console.
The manufacturer is not responsible for operations that are not included in this manual.
The manufacturer is not liable in regard to competent bodies for changes to the equipment and software that
are not approved.
In case of failure or defect, refer directly to an authorized service provider or manufacturer.
The manufacturer is not liable for injury and/or damage to persons and/or property and/or pets caused by the
failure to obey safety instructions.
All approved personnel must know all safety requirements in this manual, the configuration manual and the
user manual.
Refer directly to an approved service provider or manufacturer for questions about the operation of the
equipment.
IMPORTANT: You must read and obey all safety instructions in this manual before you use
this equipment.
WARNING: Incorrect use of this equipment that does not agree with the
instructions in this manual can cause a risk to safety.
WARNING: A minimum insulation thickness of 0.25 mm is necessary for all
internal wiring of different intrinsically safe circuits.
A grounding conductor must be connected between the I.S. ground terminals
of the Intrinsic safety barrier in the console and the power distribution panel.
This connection must have a cross-sectional area of at least 4 mm2 for the
added earth connection.
WARNING: Substitution of components can decrease intrinsic safety.
ADVESTISEMENT: La substitution des composants peut compromettre la
sécurité intrinsèque
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 8

READ CAREFULLY: The control drawing shown in ILL. 14 shall be provided with all devices.
IMPORTANT: If a replacement power supply cable is necessary, use an applicable, approved
ELBZ/7 type power cord. Do not use another type of power cable.
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 9

Section 3 Introduction
This manual was prepared in accordance with IEC 82079-1 standards. “Preparation of instructions for use -
Structuring, content and presentation - Part 1: General principles and detailed requirements and according to
the ATEX Directive 2014/34/EU concerning equipment and protective systems intended for use in potentially
explosive atmospheres."
This manual gives all necessary information about the configuration of the MagLink LX 4/LX Plus console.
IMPORTANT: This manual must be used together with the related product manuals:
M2050-EU MagLink LX 4 /LX Plus Installation Manual
M2052-EU MagLink LX 4/LX Plus User Manual
You must install the console as shown in the M2050-EU MagLink LX 4 /LX Plus Installation
Manual, configure the console as instructed in this manual and use the console in the field as
shown in the M2052-EU MagLink LX 4/LX Plus User Manual.
WARNING: This device must not be discarded with household waste. This
device is labeled in accordance with European Directive 2012/19/UE
concerning used electrical and electronic appliances (waste electrical and
electronic equipment – WEEE).
This guideline gives the methods for the return and recycling of used
electronic devices as applicable throughout the EU. To return your used
device, use the return and collection systems available to you.
The battery used in this device may present a risk of fire or chemical burn if
mistreated. Do not disassemble, heat above 50°C or incinerate.
The table that follows lists reference data of the manufacturer:
Data Description
Name START ITALIANA S.r.l.
Address
Via Natta 6
20823 Lentate Sul Seveso, (MB)
Italy
Telephone +39 0362 1581465
Fax +39 0362 1581464
Website www.startitaliana.com
e-Mail [email protected]
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 10

3.1 Safety Warnings
This manual contains many important Safety Alerts. There can be a risk of injury or damage to property if you
do not obey these alerts. The panels below show the types of safety warnings that can be seen and how
each is specified.
DANGER: Indicates an immediately hazardous condition that, if not prevented, will
result in death or serious injury.
WARNING: Indicates a possibly hazardous condition that, if not prevented, could
result in death or serious injury.
CAUTION: Indicates a possibly hazardous situation that, if not prevented, could
result in minor or moderate injury.
NOTICE: Indicates important information not related to hazards. A condition that, if not
prevented, can result in property damage.
SAFETY INSTRUCTIONS: Indicates instructions and procedures related to safety or
gives the location of safety equipment
3.2 Information Panels
NOTE: This panel gives more information about an instruction or procedure.
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 12

IMPORTANT: This panel contains special information that is important and must be read and
obeyed.
REMINDER: This panel shows information that has been given before in the manual that is
important to show again.
TIP: A step or procedure that is recommended to make another step or procedure easier.
INFORMATION: This panel shows references to more information in other sources.
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 13

Section 4 Direct Connection
This section covers how to connect directly to the console using a standard RJ45 cable.
NOTE: If you have a connection problem with a standard RJ45, as an option, try an RJ45
Crossover cable.
Connect an RJ45 cable from your laptop Ethernet port to the Ethernet port on the bottom panel of the
console.
Navigate to C o n t r o l P a n e l > A l l C o n t r o l P a n e l I t e m s > N e t w o r k a n d S h a r i n g C e n t e r on your
laptop.
1. Click Change adapter settings in the left-side panel.
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 14

2. Right-click Local Area Connections.
3. Select Properties from the menu.
4. Select to highlight Internet Protocol version 4 (IPv4) on the list in the pop-up.
5. Click Properties.
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 15

6. Set the IP address. The unit comes shipped from the factory with the IP address 10.90.10.92. Your
laptop must be set one number higher or one number lower to connect to the console. The connection
must be made on port 3000.
a. Click the button next to Use the following IP address.
b. Enter the IP address: 10.90.10.92.3000.
c. Enter the Subnet mask: 255.255.255.0.
7. Click OK.
Your laptop is now set up to communicate directly with your MagLink LX 4 console. Enter the IP address into
your browser to connect.
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 16

Section 5 Login Procedure
The Home Screen shown below will come into view after you enter the IP Address into your browser.
Under Language selection, select the radio button adjacent to the language that will be used for the
configuration.
The table that follows shows the languages that can be selected:
Console Language Selections
Chinese Simplified Chinese Traditional English
French German Italian
Polish Portuguese Spanish
Push the Enter button. The Login page will come into view.
1. Select a User type from the drop-down. There are three (3) types of Users:
nGuest: Can only see Tank Status, Sensor Status and Reports (measures, deliveries,
leakages, sudden loss). A Guest User cannot make changes to the configuration.
nAdmin: Has the same rights as Guest and can also make changes to the configuration.
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 17

nSuperAdmin: This is for internal use only.
2. Enter the Password.
NOTE: The initial password for a Guest user and Admin User can be found on the
M2054-QS Quick Start instruction that is in the box that came with your console.
These passwords are case-sensitive. Only an Admin user can change passwords.
IMPORTANT: The administrator must change the password as soon as possible to prevent
access by personnel that are not approved. See "Change Password" on page79 for
information.
TIP: As you type your password only neutral "bullet" characters will show (e.g. • • • • • •). Select
the "eye" icon to show the password characters as you type.
3. Push the LOGIN button to log in to the console with the selected user type.
4. If you did not select the applicable language in the Home screen you can push the LANGUAGE button
to go back to the Home screen.
The table that follows shows the types of data that can be seen by the two User types:
Data Type Guest Admin
Inventory X X
Historical Data Table X X
Alarm status X X
Delivery/Leakage X X
Login X X
Logout X X
Association of alarm to relays (per tank) X
Managing internal and external sensors X
Automatic print features X
Managing strapping tables X
Configuring email address book X
Configuration of all dispensers X
TCP/IP address configuration, DNS X
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 18

Data Type Guest Admin
Utility operations (Backup/restore, Clean historical data: Historical readings, alarms, reconciliation,
shift reports, Touch screen calibration of the console; Restarting the console, Restarting the
operating system of the console)
X
Reconciliation (if enabled) X
Shift report with scheduling X
Sensors current status X X
Autocalibration Analysis X
Tanks, sensors, Line leak setup X
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 19

Section 6 Admin Account
1. When an Admin User is logged in, the screen will show a Main Menu on the right side of the display.
2. When a menu item is selected, its related tabs will come into view along the top of the display (the
selected menu item will be highlighted by a blue background).
3. When a Tab is selected in the Tabs Bar it is highlighted by a yellow line.
4. When an entry in a tab has a character limit it is shown as "number of characters entered / character
limit" to the right of its entry line.
5. Each tab has a SAVE button that is used to save that tab's configuration data after it is entered.
IMPORTANT: Make sure you save the configuration data that you entered before you
continue to another tab.
6. When all applicable tabs have been configured you can click the APPLY SETTINGS TO CONSOLE
button to save all of the configuration data to the console.
TIP: It is recommended to start from the Site Info tab and complete all applicable fields. Then,
continue to the next tab to the right and complete all applicable fields. Continue this procedure
until you have completed all tabs.
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 20
Other manuals for MagLink LX4
3
This manual suits for next models
1
Table of contents
Popular Control Panel manuals by other brands

CLARCOR
CLARCOR UAS DPM owner's manual

Orenco
Orenco MVP-SSF PTRO Operation instructions

LEGRAND
LEGRAND 5 735 04 Technical data

Truma
Truma Panel BC (616) Operating instructions & installation instructions

drexel und weiss
drexel und weiss aerosilent topo Operating, Maintenance, Commissioning

Crow
Crow RUNNER 8/64 Installation & programming guide