WIL-11610-E- 02 1 WILDEN PUMP & ENGINEERING, LLC
CAUTION: Do not apply compressed air to the exhaust port
— pump will not function.
CAUTION: Do not, under any circumstance loosen the set
screw located at the adjuster dial of the Pro-Flo X™ pump.
If the set screw is loose when the pump is pressurized, it
could eject and cause injury to anyone in the area.
CAUTION: Do not over-lubricate air supply — excess
lubrication will reduce pump performance. Pump is pre-
lubed.
Temperature Limits:
Acetal –29°C to 82°C –20°F to 180°F
Buna-N –12°C to 82°C 10°F to 180°F
Geolast®–40°C to 82°C –40°F to 180°F
Neoprene –18°C to 93°C 0°F to 200°F
Nordel®EPDM –51°C to 138°C –60°F to 280°F
Nylon –18°C to 93°C 0°F to 200°F
PFA –7°C to 107°C 45°F to 225°F
Polypropylene 0°C to 79°C 32°F to 175°F
Polyurethane –12°C to 66°C 10°F to 150°F
PVDF –12°C to 107°C 10°F to 225°F
Saniflex™ –29°C to 104°C –20°F to 220°F
SIPD PTFE
with
EPDM-backed
4°C to 137°C 40°F to 280°F
SIPD PTFE
with
Neoprene-backed
4°C to 93°C 40°F to 200°F
PTFE14°C to 104°C 40°F to 220°F
FKM –40°C to 177°C –40°F to 350°F
Wil-Flex™ –40°C to 107°C –40°F to 225°F
NOTE: Not all materials are available for all models. Refer
to Section 2 for material options for your pump.
CAUTION: Canadian Standards Association (CSA)
configured pumps should not be used in temperatures
lower than 0.0°C to 52°C (32°F to 125°F).
CAUTION: When choosing pump materials, be sure to
check the temperature limits for all wetted components.
Example: FKM has a maximum limit of 177°C (350°F) but
polypropylene has a maximum limit of only 79°C (175°F).
CAUTION: Maximum temperature limits are based upon
mechanical stress only. Certain chemicals will significantly
reduce maximum safe operating temperatures. Consult
Chemical Resistance Guide for chemical compatibility and
temperature limits.
WARNING: Prevent static sparking. If static sparking
occurs, fire or explosion could result. Pump, valves and
containers must be grounded to a proper grounding point
when handling flammable fluids and whenever discharge
of static electricity is a hazard.
CAUTION: Canadian Standards Association (CSA)
configured pumps must be electrically grounded using the
grounding conductor provided. Improper grounding can
cause improper and dangerous operation.
CAUTION: For U.L. listed pumps, do not exceed 3.4 bar (50
psig) air supply pressure.
CAUTION: Do not exceed 8.6 bar (125 psig) air supply
pressure.
CAUTION: Canadian Standards Association (CSA)
configured pumps should not exceed 6.9 bar (100 psig)
natural gas supply pressure.
CAUTION: The process fluid and cleaning fluids must be
chemically compatible with all wetted pump components.
Consult the Chemical Resistance Guide.
CAUTION: Do not exceed 82°C (180°F) air inlet temperature
for Pro-Flo X™ models.
CAUTION: Pumps should be thoroughly flushed before
installing into process lines. FDA- and USDA-approved
pumps should be cleaned and/or sanitized before being
used.
CAUTION: Always wear safety glasses when operating
pump. If diaphragm rupture occurs, material being pumped
may be forced out air exhaust.
CAUTION: Before any maintenance or repair is attempted,
the compressed air line to the pump should be
disconnected and all air pressure allowed to bleed from
pump. Disconnect all intake, discharge and air lines. Drain
the pump by turning it upside down and allowing any fluid
to flow into a suitable container.
CAUTION: Blow out air line for 10 to 20 seconds before
attaching to pump to make sure all pipeline debris is
clear. Use an in-line air filter. A 5μ (micron) air filter is
recommended.
NOTE: When installing PTFE diaphragms, it is important to
tighten outer pistons simultaneously (turning in opposite
directions) to ensure tight fit. (See torque specifications in
Section 7.)
NOTE: Cast Iron PTFE-fitted pumps come standard from
the factory with expanded PTFE gaskets installed in the
diaphragm bead of the liquid chamber. PTFE gaskets
cannot be re-used.
NOTE: Before starting disassembly, mark a line from each
liquid chamber to its corresponding air chamber. This line
will assist in proper alignment during reassembly.
CAUTION: Pro-Flo X™ pumps can be used for submersible
applications, when using the Pro-Flo X™ submersible
option.
CAUTION:Tighten all hardware prior to installation.
CAUTION: The gas outlet of CSA configured pumps must
be vented to a safe location in accordance with local codes
or, in the absence of local codes, an industry or nationally
recognized code having jurisdiction over the specified
installation.
CAUTION: For U.L. listed pumps, all pipe connections are
to be made using U.L. classified gasoline-resistant pipe
compound.
CAUTION: For U.L. listed pumps all installations must
conform to NFPA 30, NFPA 30A and all other applicable
codes.
CAUTION: For U.L. listed pumps, air exhaust port is to
be connected to pipe or tubing to be routed outdoors or
other location determined to be equivalent.
CAUTION: For U.L. listed pumps, pump is to be grounded
usingthejam-nutlocatedatthetopofthelongverticalcarriage
bolt. The ground connection is marked with a tag having the
grounding symbol.
1
4°C to 149°C (40°F to 300°F) - 13 mm (1/2") and 25 mm (1") models only.
Section 1
CAUTIONS—READ FIRST!