Duemmegi Contatto ModGSMIII User manual

Contatto
ModGSMIII
ModGSM III : GSM module for remote control
ModGSMIII module allows to receive information from the
Contatto bus and to send commands using a standard
GSM mobile phone.
The way to exchange information with the Contatto bus is
based upon the SMS messages (Short Message Service :
each sent/received message contains literal strings fully
configurable by the user.
In comparison to similar systems based on DTMF tones,
ModGSMIII module allows to exclude any misunderstand-
ing about the sent commands and to have clear and explicit
information about the status of the system. ModGSMIII
contains a “GSM engine” that may operate both with re-
chargeable and contract SIM cards.
ModGSMIII requires MCP XT controller equipped with
main firmware version 3.5 or higher.
The main features of ModGSMIII module are the following:
➢Enabled telephone numbers: up to 32 telephone
numbers may be defined, from which the module ac-
cepts SMS to perform commands or to which the mod-
ule sends information via SMS.
➢Jolly number: the “jolly number” function allows to a
not listed user to send a SMS command to ModGSMIII
module, of course provided that before the commands
a well defined password has been entered.
This password must be always placed at the beginning
of SMS and can be freely set using the support soft-
ware ModGSMTools.
➢SMS from ModGSMIII to user: up to 64 SMS may be
defined, which will be sent by ModGSMIII module to
one or more phone numbers at the occurrence of an
event (e.g. alarm system, failure of the boiler, etc. ;
each one of these SMS can contain information about
one or more points of Contatto bus or about the local
input of the module.
➢SMS from ModGSMIII to user at interruption and
restoring of the power supply: thanks to an internal
rechargeable battery, ModGSMIII may be set to send
a message at the interruption and/or at the restoring of
the power supply; these two messages may be defined
by the user and they may be individually enabled.
This feature does not depend on the bus activity and it
is useful to be informed about the status of the electric-
al network of the plant. At the interruption of the power
supply, ModGSMIII module will be automatically
switched off after a programmable delay; during this
time the local inputs are still working.
➢SMS from ModGSMIII to user at
Contatto
bus fail-
ure: in addition to power supply status information de-
scribed above, ModGSMIII can be set to send a
message at the occurrence of Contatto bus failure and/
or at its restoring
➢Forwarding of SMS from ModGSMIII to user:
ModGSMIII can be set to forward all SMS, received
from not listed phone numbers, to one of the listed
phone numbers, or to a number not inserted in the list.
➢SMS from user to ModGSMIII for command execu-
tion: up to 64 “command strings” may be defined; each
string can execute up to three different actions. Send-
ing a SMS containing one or more of these strings,
ModGSMIII module will execute the specified com-
mands, but provided that the SMS has been sent from
a listed phone numbers (or from the jolly number .
Between the processing of a command string and the
next one, the module waits for a pause of 1 second. If
a command string is set to perform more actions, these
ones will be processed without any pause, so they will
be executed almost at the same time. For each com-
mand string, at least one action must be defined.
➢SMS from user to ModGSMIII for information re-
quest: the command SMS described at previous point
may contain also a request of SMS sending to the
user, reporting information about one or more points of
the system.
➢SMS from user to ModGSMIII for remaining credit
request: after proper setting, it is possible to send a
SMS to force the request of the remaining credit from
ModGSMIII to the mobile service provider when using
prepaid SIM.
➢Execution of commands by a voice call: “voice call”
is a standard call from any telephone (GSM or wired ; if
the calling number is among the enabled ones, then
ModGSMIII module will reject the calling after a pair of
rings without answer to it and it will execute the com-
mands (if enabled configured for that phone number.
This feature allows to execute some commands at zero
cost because ModGSMIII, as said, does not answer to
the voice call
➢ocal inputs and outputs: ModGSMIII provides 8 in-
puts, 2 relay outputs (with floating contacts and 2 NPN
outputs, absolutely independent from the Contatto bus;
these points may be used to acquire status and to ex-
ecute commands regardless of the bus activity.
➢og on SDCARD: ModGSMIII performs a daily re-
cording (log on SDCARD, storing all the significant
events occurred during the day.
➢Management of PIN and PUK code by the PC: it is
possible to enable/disable the PIN code of the SIM by
using ModGSMTools programs, avoiding the need to
use a third GSM phone. In addition, by PC, it is pos-
sible to change the PIN code of the SIM.
DUEMMEGI s.r.l. - Via Longhena, 4 - 20139 MILANO
Tel. 02/57300377 - Fax 02/55213686 – www.duemmegi.it
Rel.: 1.0 November 2011 Page 1 of 6
HOME AND BUILDING AUTOMATION

Contatto
ModGSMIII
SIM card and battery
To insert the SIM card remove the front panel. The SIM
holder is clearly visible and it is exactly on the GSM engine.
The SIM card must be inserted with the electrical contacts
oriented toward the bottom side.
Under the front panel is also located a jumper allowing to
connect/disconnect the Li-Ion battery. To avoid the battery
discharge, the module is provided with the jumper un-
plugged; the installer, during the setting up, has to plug the
jumper as in the following figure.
Address rogramming
ModGSMIII module takes, inside the Contatto bus, one 4-
channel input addresses, each one providing 16 digital
points to be used to perform the commands on the real or
virtual output module of the system. In other words, up to 4
x 16 = 64 input points are available; these inputs, instead to
be connected to “physical contacts”, are driven by the inco-
ming messages (SMS of ModGSMIII module. These
points will be therefore used to perform the desired actions
through a proper programming of the Contatto system. The
support program ModGSMTools allows to define the ad-
dress of ModGSMIII module. No output address are used
by this module.
Note: it is not possible to assign the bus address of
ModGSMIII module by FXPRO programmer.
A white label on the front panel of ModGSMIII allows to
write the address assigned to the module for an immediate
visual identification.
ModGSMIII must be set by the program ModGSMTools so
that to define the several parameters needed for its proper
operation; for more details refer to the programming
manual.
Wiring diagram
A 5-pole removable terminal block on the top side of
ModGSMIII module allows the connection to the Contatto
bus and to the related power supply.
A special connector on the top right side allow the connec-
tion to the antenna (provided . The antenna must be placed
in order to allow a good reception of the GSM signal. The
micro SD card is located on the top side, on the left of the
antenna connector; this SD card is provided together the
module, already inserted and properly configured, therefore
it must not be removed from is holder for any reason,
on the contrary the warranty will expire.
On the bottom left side the module provides: a 4-way ter-
minal block providing 2 potential free contacts (O1 and O2
and a 3-way terminal block for the connection of 2 external
relays (O3 and O4 ; the coil of these relays must be rated
for 24V dc current (the voltage on outputs O3 and O4 is
about equal to the voltage applied to terminals 13 and 14 .
A 9-way terminal block on the bottom right side of the mod-
ule allows the connection to the 8 local inputs that must be
otential free.
DUEMMEGI
MILANO-ITALY
MODGSM
1
ADDRESS
USB
IN
OUT
ON
SMS
INIT
2 3 4 5 6 7 8 C
O1 O2
O3 O4 +V
V~
L
N
Kx
Ky
ANTENNA
+24V
BUS
0V
L1
L2
Contatto
Power su ly 24V= ±25% / 300mA
+24V
0V
L1
L2
P
13 14 16 1715
DUEMMEGI s.r.l. - Via Longhena, 4 - 20139 MILANO
Tel. 02/57300377 - Fax 02/55213686 – www.duemmegi.it
Rel.: 1.0 November 2011 Page 2 of 6
HOME AND BUILDING AUTOMATION

Contatto
ModGSMIII
Meaning of the LEDs on front anel
A small USB connector for the connection of ModGSMIII to
the PC is located on the front panel. The red LED located
on the top of this connector reports the communication
activity between the PC and the module itself. During the
communication this LED will flash showing the information
exchange.
In addition to this USB communication LED, the following
ones are placed on the front panel:
➢ED Init
➢ED Field
➢ED SMS IN
➢ED SMS OUT
➢ED Power (ON)
The following table shows the possible combinations of the
LEDs signalling. Fourteen different situations can be identi-
fied as listed in the following table. “FF” means “Fast
Flash”, while “SF” means “Slow Flash”. Of course “ON”
means that the related LED is fixed ON and “OFF” means
that the related LED is OFF.
Init Field SMS IN SMS OUT ON USB
1 FF OFF OFF OFF ON OFF
2 SF OFF OFF OFF ON OFF
3ON ON OFF OFF OFF OFF
4ON OFF OFF OFF ON OFF
5ON ON ON ON ON OFF
6ON OFF OFF ON ON OFF
7ON OFF ON ON ON OFF
8ON OFF SF SF ON OFF
9ON OFF FF FF ON OFF
10 OFF SF x x ON OFF
11 OFF SF FF OFF ON OFF
12 OFF SF OFF FF ON OFF
13 OFF SF FF FF ON OFF
14 FF FF FF FF ON FF
The listed fourteen possible combinations will be here de-
scribed:
1 It identifies the initialization of the GSM engine. The
LED “Init” flashes quickly, with a period of 0.5 seconds
2 It identifies a problem for the internal memory of
ModGSMIII module. This may mean that the memory
has not been rogrammed or that it has been dam-
aged. The LED “Init” flashes slowly with a period of 1
second.
3 It identifies the switching OFF rocedure of ModGS-
MIII module. It starts this procedure when a power
supply failure occurs; in this case the module does not
switch OFF immediately, but it follows a sequence that
has been set by ModGSMTools program. Therefore,
for instance, it sends the SMS related to power failure
event and after the defined time delay it completely
switches OFF
4 It identifies a communication error with the GSM en-
gine. In this case the system will force an automatic re-
boot of GSM engine after 60 seconds fixed delay
5 It identifies the critical errors returned by the SIM
card, requiring a reboot of GSM engine; this will be
automatically done after 60 seconds fixed delay
6 It identifies communication roblems with the SIM
card currently placed in the module. For instance, the
SIM is not properly inserted or a SIM failure occurred.
In this case too the system will automatically reboot the
GSM engine after 60 seconds fixed delay
7 It identifies an error on entering the PIN code, for in-
stance the entered PIN code is wrong. In this case the
system enters a lock state waiting for the resolution of
the error on the PIN code. This requires a proper inter-
vention by ModGSMTools
8 It identifies an error on entering the PIN code. Unlike
the previous case, this error will be reported after a
normal start of the GSM engine. The LEDs SMS IN
and SMS OUT flash slowly with a period of 1 second.
In this case the system will automatically reboot the
GSM engine after 60 seconds fixed delay
9 It identifies that the remaining credit of the SIM card
ex ired and therefore the SIM has to be recharged
with a new credit. The LEDs SMS IN and SMS OUT
flashes quickly with a period of 0.5 seconds; after 60
seconds delay, the system will reboot the GSM engine.
This condition will be repeated at each attempt to send
a SMS in expired credit condition
10 It identifies the “normal” o eration activity, in other
words the operating condition reached after the initial-
ization and with no events pending. The field LED
flashes with a period of 2 seconds and with an
ON time in respect to the OFF time (duty-cycle vari-
able as function of the strength of the GSM signal.
More the signal strength and more the LED will be ON
during the period
11 It identifies the rece tion of a SMS. The LED SMS IN
performs a sequence of fast flashes with a period of
0.5 seconds while the field LED continues to flash nor-
mally to shows the strength of the GSM signal
DUEMMEGI s.r.l. - Via Longhena, 4 - 20139 MILANO
Tel. 02/57300377 - Fax 02/55213686 – www.duemmegi.it
Rel.: 1.0 November 2011 Page 3 of 6
HOME AND BUILDING AUTOMATION

Contatto
ModGSMIII
12 It identifies the sending of a SMS. The LED SMS OUT
performs a sequence of fast flashes with a period of
0.5 seconds while the field LED continues to flash nor-
mally to shows the strength of the GSM signal
13 It identifies the rece tion of a voice call, both LEDs
SMS IN and SMS OUT flash quickly with a period of
0.5 seconds while the field LED continues to flash nor-
mally to shows the strength of the GSM signal
14 It identifies that the procedure of firmware u dating of
the main microcontroller of ModGSMIII module is run-
ning. All LEDs, with the exception of ON LED, flashes
quickly with a period of 0.5 seconds
Ma ing
By MCP Ide (release 3.0.5 or higher it is possible to dis-
play the map related to ModGSMIII as shown in the figure
on the bottom of this page.
Like for all modules of Contatto family, the background of
the module symbol is in green colour if the module is con-
nected and properly operating, else the background will be
red.
As said before, ModGSMIII module takes only one input
address, 4-channel 16-bit each one (from Ix:1.1 to Ix:4.16 .
When one of these points becomes active, the related
“circle” will be red coloured.
Messages exam les
Granted that the specific programming manual is the uni-
que reference for the configuration of ModGSMIII module,
simple examples will be described in the following only to
point out some performances of the module.
➢Messages from ModGSMIII to user: each SMS mes-
sage transmitted by ModGSMIII may report informa-
tion about one or more points, both digital and analog
ones (e.g. temperature ; the composition and the con-
tent of the messages are fully configurable by the user
through the tool program ModGSMTools.
This program allows to assign a well defined string to
each local input of ModGSMIII and to each Contatto
input and output point (real or virtual or analog or re-
gister . In details, the following information must be
defined:
✗the Contatto point to which the string is referred
✗a name (or phrase to be assigned to the point
status when it is at “0” logic level (e.g. “Alarm sys-
tem normal” or the name of the analog value
✗a name (or phrase to be assigned to the point
status when it is at “1” logic level (e.g.. “Alarm sys-
tem activated”
✗the event that causes the sending of the message,
for each SMS, and to which phone number it must
be sent (also more than one phone number
The following is an example of SMS message that user
can receive from ModGSMIII module:
Note as the message reports more information about
the Alarm System status and a temperature (this is only
an example . Another example of SMS from ModGS-
MIII to user may be the following:
DUEMMEGI s.r.l. - Via Longhena, 4 - 20139 MILANO
Tel. 02/57300377 - Fax 02/55213686 – www.duemmegi.it
Rel.: 1.0 November 2011 Page 4 of 6
HOME AND BUILDING AUTOMATION
Graphical representation of ModGSMIII in the map of MCP Visio

Contatto
ModGSMIII
➢Messages from user to ModGSMIII for command
execution or information request: each SMS mes-
sage sent by the user to ModGSMIII module may con-
tain one ore more commands; the commands can act
on the local outputs of the module or on one or more of
the 64 fictitious inputs provided by ModGSMIII (re-
member that the module is seen by the bus as an input
module with 4 addresses, 16 points each one; these in-
puts must be used in the Contatto equations to per-
form the desired actions .
The tool program ModGSMTools allows to define all
required information as follows:
✗the string that, once received by ModGSMIII,
causes a command (e.g. Close-Shutters
✗the type of command to be executed; the possible
options are:
ON (switch ON an input point of ModGSMIII or
a local output
OFF (switch OFF an input point of ModGSMIII
or a local output
Pulse (causes a pulse on an input point of
ModGSMIII or on a local output; the duration
of the pulse is 1 second
Send a SMS (cause the sending to the user of
a SMS that may be selected among the
defined ones
✗the point on which the selected action must be ex-
ecuted; each point has to be chosen among the 64
fictitious input points or among the 4 local outputs
provided by ModGSMIII module
✗a comment to be assigned to the point
The following examples show command messages from
user to ModGSMIII module:
In the second example, in addition to “physical” commands,
note the string AlarmStatus that will cause the sending to
the user of a SMS reporting the Alarm System status.
This is an example of message containing an information
request.
For more details about the programming, as said be-
fore, refer to the specific programming manual of
ModGSMIII module.
Technical charact eristics
Power supply 24V SELV ±25%
Current consumption MAX 0.3A @ 24V
Internal battery 3.6V / 1100mAh Li-Ion
Local inputs 8
Current for each input 1mA MAX
MAX voltage on output
contacts O1 and O2 60V , 250V~
Contact rating (O1 and O2 1A @ 60V , 1A @ 250V~
MIN load on contacts O1 and
O2
10mA @ 12V
Type and MAX output current
on output O3 and O4
NPN, 150mA
+V voltage for supplying
external relays
equal to the module supply
voltage itself
Occupied address in the
Contatto bus
1 address, 4-channel 16-bit
each one
Number of outgoing SMS 64 + 4 for breaking/restoring of
power supply and bus
failure/OK
Number of incoming SMS for
commands
64, each one with up to 3
different actions
Number of phone numbers for
outgoing/incoming SMS
32 plus jolly number
Number of voice call for
command execution
1 for each phone number
Additional features: - forwarding of SMS received
from not listed numbers to a
chosen number
- credit request feature
- management of PIN and PUK
by PC
-LOG on SD CARD
GSM ENGINE DA A:
Frequency bands 850, 900, 1800 and 1900 MHz
Transmit power - Class 4 (2W for 850/900
- Class 1 (1W for 1800/1900
Sensitivity -106dBm
SIM interface slot SIM card 1,8/3V
PC interface USB
Housing Standard DIN 6M for DIN rail
Operating temperature -5 ÷ +50 °C
Storage temperature -20 ÷ +70 °C
Protection degree IP20
Outline dimensions
58mm
106mm
90mm
DUEMMEGI
MILANO-ITALY
MODGSM
1
ADDRESS
USB
IN
OUT
ON
SMS
INIT
2 3 4 5 6 7 8 C
O1 O2
O3 O4 +V
Contatto
Power su ly 24V= ±25% / 300mA
+24V
0V
L1
L2
P
13 14 16 1715
DUEMMEGI s.r.l. - Via Longhena, 4 - 20139 MILANO
Tel. 02/57300377 - Fax 02/55213686 – www.duemmegi.it
Rel.: 1.0 November 2011 Page 5 of 6
HOME AND BUILDING AUTOMATION

Contatto
ModGSMIII
Correct dis osal of this roduct
(Waste Electrical & Electronic Equipment
(Applicable in the European Union and other
European countries with separate collection sys-
tems . This marking on the product, accessories or
literature indicates that the product should not be
disposed of with other household waste at the end
of their working life. To prevent possible harm to the environment
or human health from uncontrolled waste disposal, please separ-
ate these items from other types of waste and recycle them re-
sponsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they pur-
chased this product, or their local government offce, for details of
where and how they can take these items for environmentally safe
recycling.
This product and its electronic accessories should not be mixed
with other commercial wastes for disposal.
Specifically about the battery, check local regulations for correct
disposal. Never use municipal waste.
Installation and use restrictions
Standards and regulations
The design and the setting up of electrical systems must be per-
formed according to the relevant standards, guidelines, specifica-
tions and regulations of the relevant country. The installation,
configuration and programming of the devices must be carried out
by trained personnel.
The installation and the wiring of the bus line and the related
devices must be performed according to the recommendations of
the manufacturers (reported on the specific data sheet of the
product and according to the applicable standards.
All the relevant safety regulations, e.g. accident prevention regula-
tions, law on technical work equipment, must also be observed.
Safety instructions
Protect the unit against moisture, dirt and any kind of damage dur-
ing transport, storage and operation. Do not operate the unit out-
side the specified technical data.
Never open the housing. If not otherwise specified, install in closed
housing (e.g. distribution cabinet . Earth the unit at the terminals
provided, if existing, for this purpose. Do not obstruct cooling of the
units. Keep out of the reach of children.
Setting up
The physical address assignment and the setting of parameters (if
any must be performed by the specific softwares provided togeth-
er the device or by the specific programmer. For the first installa-
tion of the device proceed according to the following guidelines:
•Check that any voltage supplying the plant has been removed
•Assign the address to module (if any
•Install and wire the device according to the schematic dia-
grams on the specific data sheet of the product
•Only then switch on the 230Vac supplying the bus power sup-
ply and the other related circuits
Applied standards
This device complies with the essential requirements of the follow-
ing directives:
2004/108/CE (EMC
2006/95/CE (Low Voltage
2002/95/CE (RoHS
EN 55022 Class B
FCC Parts 15,22 & 24, Class B
3GPP TS 51010-1, Section 12.2
Note
Technical characteristics and this data sheet asre subject to
change without notice.
DUEMMEGI s.r.l. - Via Longhena, 4 - 20139 MILANO
Tel. 02/57300377 - Fax 02/55213686 – www.duemmegi.it
Rel.: 1.0 November 2011 Page 6 of 6
HOME AND BUILDING AUTOMATION
Table of contents
Other Duemmegi Control Unit manuals
Popular Control Unit manuals by other brands

Moxa Technologies
Moxa Technologies EOM-104 Series Quick installation guide

Fagor
Fagor MCS Series manual

Nice
Nice ROBO PLUS Installation instructions manual

Zapp
Zapp PM752 user manual

ZIEHL-ABEGG
ZIEHL-ABEGG UNIcon CTG-150AV operating instructions

National Instruments
National Instruments NI FlexRIO installation guide

Vertiv
Vertiv NetSure7100 Series Installation and user manual

AMX
AMX CAT-5 RGBHV RX quick start guide

Siemens
Siemens SINUMERIK 840D sl Programming manual

Siemens
Siemens SIRIUS ACT 3SU1400-1GE10-1AA0 Original operating instructions

AirPatrol Lite
AirPatrol Lite Lite user manual

SecureVision
SecureVision FD 4201 instruction manual