Line Regulation............................................................................................................................................... 0.1% Max from 115-130 VAC
Efficiency .....................................................................................................................................................................................80% typical
Cooling...................................................................................................................................................................................... Convectional
Dimensions (all units) .............................................................................192mm L x 178mm W x 45.5 mm H 7-5/8” L x 7” W x 1-13/16” H
Enclosure.................................................................................................................................................................................. Steal, vented
Power Cable ...............................................................................................................................3 wire grounded with CEE input connector
Output Terminals ..................................................................................................................................................................... Binding Posts
Quality Assurance ......................................................................................................................................................... ISO 9001 standards
Safety ................................................................................................................................................................................... UL Recognized
WARNING:
The individual user should take care to determine prior to use or installation whether this device is suitable, adequate, or safe for the
use intended. Since individual applications are subject to great variation, DuraComm makes no representation or warranty as to the
merchantability, suitability or fitness of these units for any specific application.
Precision regulated power supplies operate internally from voltages in excess of 300 volts. In rare cases, voltage spikes or
transients on the AC power line, or over heating, may cause a component failure in the power supply. If this failure results in over
voltage at the output terminals, the electronic over voltage feature will operate. Overload of the output will cause the over current
feature to operate. In either case, the cause must be determined and corrected.
Failures require investigation as to the cause and/ or repair of the unit. THIS UNIT DOES NOT HAVE ANY USER SERVICEABLE
PARTS. SERVICE AND REPAIR MUST BE REFERRED TO QUALIFIED PERSONNEL.
OPERATION:
Connect your 12 volt DC device to the red (positive) and black (negative) binding posts. Be certain you connect positive to positive (red)
and negative to negative (black). Insert the AC plug into an AC outlet of the proper voltage.
Press the ON/OFF switch to the ON position and observe that the indicator light illuminates. If the indicator light fails to light,
recheck the equipment installation, hook-up polarity, and the AC outlet.
PRECAUTIONS: DO NOT block any openings in the case or operate the unit in a hot, enclosed environment or compartment. Be sure
adequate ventilation is provided since heat build-up will shorten component life. NOTE: Most audio and radio equipment draws much
less average current than the peak demand.
If the unit stops working, check the 12 volt connections for tightness. If the unit fails again or repeatedly, have the unit checked
by a qualified technician. HAZARDOUS VOLTAGES EXIST INSIDE THE UNIT. THERE ARE NO USER SERVICEABLE PARTS
INSIDE. DO NOT EXPOSE THE UNIT TO RAIN OR MOISTURE.
Warning: The DuraComm series of desk top power supplies are accurately regulated to maintain output voltage from no load to full
load. Slightly above the rated output load, the current limiting circuit begins to act, reducing the output voltage to prevent unit overload
damage. Some loads, like incandescent lamps will have start-up current loads that are up to ten times the normal “hot” current drain. To
ensure the DuraComm power supply will not encounter current limiting shut down; only operate incandescent loads that are about one-
half to two-thirds of the maximum current rating.
NOTE: This device complies with part 15 of the FCC rules. Operation is subject to the following 2 conditions; 1) This device may not
cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired
operation.
!
!
!
!