Duratech LINK Driver PLP-REM-300 User manual

English....................Page 3
Nederlands.......Pagina 23
Français...............Page 43
Deutsch...............Seite 63
Español.............Página 83
PLP-REM-300
Manual
LINK Driver

2

3
ENG
Table of contents
Technical specifications
General Specifications
PLP-REM-300 overview
Logic board
Installation Instructions
Single PLP-REM-300 unit
Multiple PLP-REM-300 installation
Operation modes
DIP switch functionalities
Transmitter functions
Operation mode: PLC
Operation mode: ON/OFF
Replacing transmitter keypad
Transmitter battery
Pairing the handheld transmitter
LinkTouch ready transmitters: OLD & NEW mode
DMX 512 communication
Single PLP-REM-300 unit
Multiple PLP-REM-300 installation
RS-485 communication
Single PLP-REM-300 unit
Multiple PLP-REM-300 installation
RS-485 command set
RESET procedure
Troubleshooting
Pool light wiring instructions
Wiring remark
Page 4
Page 4
Page 5
Page 6
Page 7
Page 8
Page 9
Page 10
Page 10
Page 11
Page 11
Page 12
Page 13
Page 14
Page 15
Page 16
Page 16
Page 17
Page 18
Page 19
Page 20
Page 22
...........................................................
.........................................................
..............................................................................
.....................................................
......................................
..................................................................................
....................................................................
............................................................
.....................................................
...............................................
..................................................................
.........................................
...........
.....................................................
.....................................
.....................................................
.....................................
...........................................................................
...................................................................................
.....................................................................................
..............................................................
.........................................................................................

4
Technical specifications
General specifications
Input Voltage: 230 VAC 50Hz
Output Voltage: 12 VAC
Transformer VA rating: 350VA
Max output Power: 300 VA (12 VAC / 25A)
Max rating relay contact A &B 16A / 250 VAC
Max switching power A & B 4000VA
RF band 868 MHz
Ambient Air Temperature: 0°C to +40°C
Humidity 10% to 90% RH - non condensing
Ingress protection rate: IP54
IEC Protection Class: Class II
PLP-REM-300 overview
12 VAC
Transformer
Integrated toroïdal
Transformer 350VA
Circuit breakers
Logic board
For details:
see next page
12VAC connection
terminals
To connect the pool
lights

5
ENG
Logic board
DMX Address dial
To choose the
DMX start address
CAN bus
12VAC connection
terminals
To connect the pool
lights
DIP switch
To select controller functionalities
RS-485
connection
To connect to
home automation
system
(see page 16)
SD card slot
For firmware updates
DMX input/outpout
The PLP-REM can act
as a DMX receiver with
DMX passthrough
A/B output
For auxiliary circuits
Acts as a SPST
(single-pole, single-
throw) switch
Status LED’s:
(1) General status
Green = OK
Red = error overvoltage or overcurrent
(2) Pairing / RESET status
(3) 12VAC to Pool lamps (Green = ON)
(4) Switch A (Green = ON)
(1)
(2)
(3)
(5)
(4)
(8)
(6)
(7)
(5) Switch B status (Green = ON)
(6) CAN status
(7) RS-485 signal
(8) DMX signal
Pairing / RESET
button
DuraLink RF board
For wireless communication
DuraLink

6
Installation Instructions
Single PLP-REM-300 unit
.Connect a 230VAC power source to the 230VAC terminals of the
PLP-REM-300. Connect the pool lights to the 12VAC connection terminal
block in the PLP-REM-300.
.The PLP-REM-300 has a 300VA transformer built in. The total power load
of pool lights (+ cable losses) may not exceed this.
230VAC
Connect the pool
lights to the 12VAC
terminals
Connect the
230VAC power
source to the
circuit breaker

7
ENG
230VAC
230VAC230VAC
Multiple PLP-REM-300 installation
For extended installations (total lamp power > 300VA), multiple PLP-REM-
300’s can be linked together. This way, a perfect synchronisation of all pool
lights is still guaranteed.
The PLP-REM-300’s need to communicate with each other, to ensure all
the lamps are in perfect sync.
Connect the PLP-REM-300’s with each other using the CAN bus:
Connect the CAN terminals of the first PLP-REM-300 with the CAN terminal
of the second PLP-REM-300*.
If more than 2 PLP-REM-300’s are necessary, simply daisy chain each CAN
terminal with the one from the next PLP-REM-300 (see below).
Respect the polarity of the terminals! (CAN L & H)
Next, set the DIP switches on the PLP-REM-300’s to the correct MASTER/
SLAVE setting. The first PLP-REM-300 will be the MASTER. All the others will
be SLAVE’s. Refer to page 9 for Master/Slave DIP switch info.
CAN BUS
set as MASTER set as SLAVE set as SLAVE
* We recommend using a shielded twisted pair cable (min. 0,5mm² - up to 200m) to connect
multiple PLP-REM-300’s using the CAN bus.
In a Master/Slave setup, only the PLP-REM-300 that is set as MASTER
will react to transmitter commands. Any additional transmitters will
need to be paired with this MASTER PLP-REM-300
!

8
ON/OFF PLC
Compatible lamps
Switch lamps ON/OFF YES YES
Change lamp color YES(1) YES(1)
Operate Relay A & B YES YES
Dimming lamps NO YES(1)
DMX control NO YES
RS-485 control YES(2) YES
Dip switch setting DIP 1 ON DIP 1 OFF
Remote keypad type(3)
Operation Modes
The PLP-REM-300 controller has 2 main operation modes:
“ON/OFF control mode” & “PLC control mode”. Each mode has it’s own
functionalities:
1) Only for RGB lamps
2) In ON/OFF control mode, only a few RS-485 commands are available (see p 17)
3) Depending on which control mode is selected, the keypad of the transmitter needs
to be changed

9
ENG
DIP switch functionalities
The DIP switch on the main circuit board of the PLP-REM-300 allows the
user to customise the way the PLP-REM-300 operates.
* Fast DMX setting
Only for Adagio Pro lamps from 2018 and onwards
DIP SWITCH
function setting 1 2 3 4 5 6
Operation Mode ON/OFF ON
PLC OFF
Relay A PULSE mode ON
TOGGLE mode OFF
Relay B PULSE mode ON
TOGGLE mode OFF
Fast DMX setting * FAST ON
STANDARD OFF
DMX NO LOOP ON
LOOP OFF
MASTER/SLAVE mode SLAVE ON
MASTER OFF
ON position
OFF position
CAUTION: Always switch o the main power supply to the
PLP-REM-300 before changing the DIP switches

10
Transmitter functions
Short push (< 1 sec):
Toggle all lamps ON or OFF
Short push:
Go to next color program
Long push:
Auto sync procedure (3)
OPERATION MODE: PLC (default mode)
Short push:
Toggle output A ON/OFF
Long push:
/
Short push:
Toggle output B ON/OFF
Long push:
/
Short push (< 1 sec):
Toggle all lamps ON or OFF (1)
Long push (> 2 sec(2)):
All lamps & “12VAC TO LAMPS” relay are turned OFF (1)
Short push:
Go to next color program
Long push:
Toggle output A ON/OFF
Short push:
Go to the previous color program
Long push:
Toggle output B ON/OFF
Short push:
Select next dimming level:
100% -- 50% -- 25% ---> 100% -- ...
Long push:
Set lamps to Program 1 (blue) & full brightness
(1) Lamp ON or OFF status is memorized after power down
(2) The green LED in the transmitter will light up as soon as you start pressing a button, and will stop
after 2 seconds, so you know exactly when to release the button.
(3) The lamps will be turned o for 30 seconds and then switched ON/OFF 3 times. This will set all
lamps to program 1: blue
OPERATION MODE: ON/OFF

11
ENG
Replacing transmitter Keypad
Depending on which control mode is selected, the keypad of the transmitter
needs to be changed:
• Remove the philips head screw and open the transmitter
• Replace the Keypad in the top part of the transmitter housing
• Reassemble in reverse order
Keypad for
ON/OFF mode
Keypad for
PLC mode
Transmitter battery
+
• Remove the philips head screw and open the transmitter
• Replace the battery, respecting the polarity
Battery type: A23 12V
Check battery status:
Replacing transmitter battery:
Push and release any button on the remote. The green LED should still light
up 0,5 second after you released. If the LED stops faster, then the battery
needs to be replaced

12
Pairing the handheld transmitter to the PLP-REM-300
All handheld transmitters are already paired in the factory and ready to use.
In case a problem arises, the pairing process can be done as below:
Pairing Indicator LED
(blue)
Pairing button
1) Press the pairing button on the circuit board, inside the PLP-REM-300
---> The BLUE LED will start to blink
2) Within 25 seconds, push any button on the handheld transmitter.
---> If the remote is paired correctly, the BLUE LED will flash slowly for 5 times
---> UNPAIRING:
See RESET procedure: page 18
DuraLink

13
ENG
LinkTouch ready transmitters: OLD & NEW mode
The “Old” mode is only used when your PLP-REM-300 is not “LinkTouch
ready”
The “New” mode is only used when your PLP-REM-300 is “LinkTouch
ready”
The mode can only be switched on transmitters which have a sticker
“LinkTouch ready” at the backside
Instructions to change the mode
1) Press and hold the “DIM” button
---> the LED turns ON for about 2 seconds
turns OFF for about 4 seconds
starts to BLINK
2) Release the “DIM” button
3) Press “UP” to select the “New” mode or
4) Press “DOWN” to select the “Old” mode
The remote is now set to the selected mode and ready for use
LED
UP
DOWN
DIM

14
230VAC
DMX 512 communication
Single PLP-REM-300 unit
1) Make sure DIP switch 1 is switched OFF.
2) Make sure the lights are turned ON with the remote first.
Address dial
Address dial setup
Setting the DMX address of the PLP-REM-300:
Select the desired number on the address dial. The chosen number deter-
mines the DMX addresses of the PLP-REM-300 & lamps.
Each lamp uses 3 bytes of DMX data (R-G-B), and all lamps receive the same
DMX data from the PLP-REM-300.
Connect DMX
panel
to DMX IN (+/-)
DMX PANEL
The DMX start address can be overruled by using the RS-485 command:
“set DMX start address” (see page 17)
DMX
address 1 2 3 4 5 6 7 8 9 ...
0 1 2 ...
R G B R G B R G B ...
Address dial
position

15
ENG
230VAC
230VAC230VAC
Multiple PLP-REM-300 installation
DMX PANEL
Address dial Address dial
Address dial
1) Connect the DMX panel to the “DMX IN” port of the first PLP-REM-300
2) Connect the PLP-REM-300’s with each other (open loop):
DMX OUT --> DMX IN (polarized terminals + -)
3) Set the DMX address for each PLP-REM-300 via the address dial.
- Option 1:All PLP-REM-300’s can be set to the same address:
This implies that all lamps will receive the same DMX data,
And will all operate identically
- Option 2:PLP-REM-300’s can be set to dierent addresses:
Each PLP-REM-300 will have it’s own group of connected lamps
that will operate identically.
However, since each PLP-REM-300 has it’s own unique address,
the dierent lamp groups can be controlled separately

16
RS-485 communication
230VAC
RS-485 Source
1) Make sure DIP switch 1 is switched OFF.
2) Make sure the lights are turned ON with the remote first.
3) Connect the RS-485 source to the “485” port on the PLP-REM-300
4)Communication settings: 9600, 8, 1, n
5) Command list: see page 17
Single PLP-REM-300 unit
1) Connect the PLP-REM-300’s with each other via the CAN bus (see page 7)
2) Make sure DIP switch 1 is switched OFF
3) Make sure the lights are turned ON with the remote first.
4) Connect the first PLP-REM-300 with the RS-485 source like described
above. This PLP-REM will be the Master.
5) Communication settings & command list: see above
Multiple PLP-REM-300 installation

17
ENG
RS-485 Command set
Command Command Remark Example available in
ON/OFF mode
available in
PLC mode
Lamps OFF PL0 All lamps OFF X X
Lamps ON PL1 All lamps ON X X
Program UP PsU Jump to next program X X
Program Down PsD Return to previous program X
Set Program PSxx xx is the decimal representaon
of the program number (01 - 14) PS06 = jump to program 6 X
Auto sync procedure PsS executes the auto sync procedure (see page 10) X X
White 1 PW1 Jump to White 1 (program 12) X
White 2 PW2 Jump to White 2 (program 13) X
White 3 PW3 Jump to White 3 (program 14) X
Set RGB PCrrrgggbbb rrr, ggg and bbb are the decimal representaon
of the RGB value (with leading zero’s)
1) PC255128064 = Full output level on Red color, half out-
put level on Green color, 1/4 output level on Blue color
2) PC255255255 = All colors at full output level
3) PC000000000 = All colors OFF
X
Set Dim value PDxxx set the OUTPUT value of the lamp in % (000 -
100) PD075 = 75% output level (on all LED’s) X
set DMX startAdress PAxxxyz y = ‘e’ or ‘E’ PA035E = set DMX start address to 35 [35(R), 36(G),
37(B)] X
Set color in percentage Pprgbe variable size, rgb = ASCII 0-255, e = end character Pp25050100e = Red 25%, Green 50%, Blue 100% X
Set color in hex Pcrgbe variable size, rgb = ASCII 0-255, e = end character Pc64128255e = Red 25%, Green 50%, Blue 100% X
Relay A control PRAx x = 1 (ON), 0 (OFF), P (Pulse) !this overrules
dipswitch PRA1 = Relay A ON PRA0 = Relay A OFF X X
Relay B control PRBx x = 1 (ON), 0 (OFF), P (Pulse) !this overrules
dipswitch PRB1 = Relay B ON PRB0 = Relay B OFF X X
ON/OFF relay control PRMx x = 1 (ON), 0 (OFF) PRM1 = Relay ON/OFF control ON X X
Color temperature PTxyz x = ten thousand ; y = thousand ; z = hundred PT035 = Set white color temperature to 3500K (in steps
of 500K) X

18
RESET procedure
RESET procedure for the control board
1) Make sure the PLP-REM-300 is powered ON
2) Press and hold the RESET button on the logic board
3) The blue LED will light up
4) Release the RESET button when the blue LED turns o
The control board has been RESET.
And all transmitters have been unpaired.
RESET
button
Blue
LED
DuraLink
!

19
ENG
Troubleshooting
PROBLEM SOLUTION
The PLP-REM doesn’t react to
transmitter commands
• Perform a RESET procedure
• Check the battery of the handheld
transmitter (see p.11)
• The transmitter is not paired-
correctly with the PLP-REM.
Repeat the pairing process
• Reduce the distance between
handheld transmitter and PLP-REM
and/or remove obstacles
• Check the General status light on
the logic board. If it’s red, then
the secondary voltage is too high
(>14VAC) or there is a short circuit
The pool lights don’t work
or don’t change colors
correclty
• Perform a RESET procedure
• Check if all connections are made
according to the electrical scheme.
• Switch the PLP-REM-300 to ON/
OFF mode (DIP switch nr 1) and
check if the lamps work
Handheld transmitter does not
function anymore after firmware
update of the PLP-REM-300 for
LinkTouch compatibility
• Buy a new TX868 transmitter that
has updated firmware

20
Pool light wiring instructions
Each lamp is connected to the transformer by a separate cable
(Preferred for new installations)
Separate cable ( not included )
Pool
house
Pool
4m cable included in lamp package !Always use a toroïdal transformer
SELECT
CABLE SECTION & MAXIMUM LENGTH
Table of contents
Languages:
Other Duratech Control Unit manuals
Popular Control Unit manuals by other brands

Honeywell
Honeywell TM300 installation instructions

Assured Automation
Assured Automation 38 Series Installation, operation & maintenance manual

spherag
spherag ATLAS 2 quick start guide

Farenheit
Farenheit AVC 3 instruction manual

H3C
H3C PSR2400-12AHAH-B user manual

Honeywell
Honeywell Silent knight 5895XL manual

Emerson
Emerson ENARDO 860 Series instruction manual

Delta Controls
Delta Controls DFM-1616 installation guide

AzureWave
AzureWave AW-GA800BT user guide

SOMFY
SOMFY Control Box 3S io installation instructions

Heliodyne
Heliodyne DELTA-T PRO installation guide

Siemens
Siemens SINUMERIK 840D sl Configuration manual