DVS VR01-085 User manual

Page 8
MT04-001 AquariTherm Tap (Manual) www.dartvalley.co.uk
Revision No. MAQTIN16071301
Warranty
The Safe Ensuite in Wall Basin is guaranteed for 5 years from
purchase against defective material and assembly.
Support
For technical support please visit our technical pages on our
website at www.dartvalley.co.uk or contact us:
techsupport@dartvalley.co.uk
+44 (0)1803 529021
Head Office
Dart Valley Systems Ltd
Kemmings Close
Long Road
Paignton
Devon
TQ4 7TW
UK
The fixing kit supplied is suitable for fixing to IPS panels up to
25mm thick, for brick or concrete walls please see options below:
VR01-006 Fixing kit for 100mm walls
VR01-007 Fixing kit for 150mm walls
VR01-008 Fixing kit for 250mm walls
Each kit includes:
4 x 10mm Steel threads
2 x ½” BSP Brass threads (for sensors)
Typical Installation
Dart Valley Systems Ltd | Kemmings Close | Long Road | Paignton | Devon | TQ4 7TW | UK
t +44 (0)1803 529021 | f+44 (0)1803 559016 | techsupport@dartvalley.co.uk | www.dartvalley.co.uk
Page 4
PP00-714 171018
PP00-714 171018
Step 1 : Safety first Step 2 : Parts
These instructions relate to the use of the Safe Ensuite in Wall
Basin only, any external or ‘add-on’ parts will be supplied with
separate instructions.
It is recommended that the electrical part of the installation
be carried out by a qualified electrician in accordance with the
latest electrical regulations. It is also recommended that any
plumbing is carried out by a qualified plumber.
IMPORTANT : Please read these instructions carefully
and follow each stage in order!
Waste grid
VR01-032 (x1)
Waste bung
VR01-033 (x1)
1¼” plastic
male iron
VR00-035 (x1)
Square washer
PP00-031 (x4)
M10 hex nut
PP00-114 (x4)
M10 A11 thread
PP00-210 (x4)
*Not supplied
˜Sold separately
VR01-085 (basin)
Cold water supply
Valve*
Warm (mixed) water supply
Hot water supply
TMV*
Warranty & Support
VR01- 085
Safe Ensuite In Wall Basin
Installation Instructions
Non-return valve*

Page 3
MT04-001 AquariTherm Tap (Manual) www.dartvalley.co.uk
Revision No. MAQTIN16071301
Page 2
MT04-001 AquariTherm Tap (Manual) www.dartvalley.co.uk
Revision No. MAQTIN16071301
Step 4 : Sensor Installation
Page 3
Step 6 : Cleaning
Step 3 : Wall Preparation & Drilling Template
*Sold separately
Sensor ½” BSP washer*
½” BSP serrated washer*
½” BSP backnut
To fit sensor securely, tighten the ½” BSP backnut by hand as far
as possible. Using a spanner tighten the backnut a further ½ turn.
M10 aII thread
Waste pipe*
1¼”
plastic
male iron
Waste grid
*Not supplied
Install fittings as shown, ensuring the M10 threads are screwed
fully into the basin, and that the waste male iron adaptor must be
fully tightened to secure the waste grid firmly in position. Once
the basin is in the wall, feed the studding through to the unistruts.
Once the unistruts are in the right position tighten the nuts by
hand as far as possible then, using a spanner, tighten the backnut
a further ½ turn.
IMPORTANT : The fixings on this basin must be tightened
to the recommended settings as per these instructions. It
is also important that the sensors are not over tightened
during step.5.
Locating correct position
Please note - Maximum cable runs
Routing of cables back to the control box should be planned at
this stage.
Cut a 420mm x 440mm hole to allow the basin to sit in the wall
NOTE : As a guide, UK guidelines recommend a distance
from the rim of the basin to the floor of between 780 and
800mm (standard use) / 720 and 740mm (disabled use).
This is a specialist product and should NOT be compared with standard porcelain sanitaryware, it is finished using a standard sanitaryware gel
coat that requires cleaning on a daily basis to keep it looking at its best, care should be taken and only recommended cleaning products should be
used. Please see list on web site or if in doubt contact Customer Support at DVS.
(DVS recommend Ecolab Maxx Into Citrus 2 for daily cleaning)
PRODUCT CLEANING
For day to day cleaning we recommend using an approved product such as “Ecolab Maxx”
Wash product removing any loose particles, apply cleaner then wash and rinse using warm water ensuring all cleaner is removed, we also
recommend wiping the surface area dry.
WC CLEANING ONLY
For day to day cleaning for the WC pans we recommend using an approved product and standard toilet brush giving attention to the U bend area.
Flush WC pan before cleaning making sure there are no loose particles in the U bend, apply cleaner and wash surface area using a soft cloth, the
U bend should be cleaned as mentioned above. Once finished, flush toilet to remove any cleaner residue or grime. If necessary flush again, wipe
surface area dry.
If these instructions are followed daily, your product should last for many years.
WARNING.
DO NOT use abrasive materials or cleaners.
Standard cloths and WC brushes only should be used, although abrasive cleaners will not damage the product it will dull the surface.
Hair dyes and other household colourants should NOT be used with these products.
Strong disinfectants or bleach should be avoided but if used should be diluted and flushed away immediately after cleaning. DO NOT leave
undiluted bleach on the surface material.
Step 5 : Fittings Installation
Sensor*
Square washer M10 hex nut
Popular Safe manuals by other brands

SPORTS AFIELD
SPORTS AFIELD SA-CV2-K instruction manual

SentrySafe
SentrySafe Master Lock Fire-Safe FPW082FS owner's manual

RHINO METALS
RHINO METALS Longhorn LSB1014 owner's manual

Arregui
Arregui AWA SAFEBOX instructions

Crown
Crown Berman FS Series instruction manual

Stack-On
Stack-On SS-22-MG-C instructions