manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Dwyer Instruments
  6. •
  7. Control Panel
  8. •
  9. Dwyer Instruments Magnehelic A-286 Series Installation and operating instructions

Dwyer Instruments Magnehelic A-286 Series Installation and operating instructions

Popular Control Panel manuals by other brands

GENEVO PRiMA 6 installation manual

GENEVO

GENEVO PRiMA 6 installation manual

NAPCO X 255 - Programming instructions

NAPCO

NAPCO X 255 - Programming instructions

Next Systems UNIR1 230 instruction manual

Next Systems

Next Systems UNIR1 230 instruction manual

HORNER HE-XPW1E0 user manual

HORNER

HORNER HE-XPW1E0 user manual

DSC CLASSIC PC1555 instruction manual

DSC

DSC CLASSIC PC1555 instruction manual

Bosch Solution 2000 installation guide

Bosch

Bosch Solution 2000 installation guide

VRinsight MS Panel user manual

VRinsight

VRinsight MS Panel user manual

Zeiss SYCOP 3 Quick reference guide

Zeiss

Zeiss SYCOP 3 Quick reference guide

HULTSTEINS ECOFRIDGE DISPLAY user manual

HULTSTEINS

HULTSTEINS ECOFRIDGE DISPLAY user manual

Elkron C420 Programming manual

Elkron

Elkron C420 Programming manual

GST GST200-2 Installation and operation manual

GST

GST GST200-2 Installation and operation manual

Efka Variocontrol V810 instruction manual

Efka

Efka Variocontrol V810 instruction manual

RDZ PC-HRX user manual

RDZ

RDZ PC-HRX user manual

STG-BEIKIRCH MZ3 operation instruction

STG-BEIKIRCH

STG-BEIKIRCH MZ3 operation instruction

AMX AutoPatch CP-15 instruction manual

AMX

AMX AutoPatch CP-15 instruction manual

Cebora 208-10 instruction manual

Cebora

Cebora 208-10 instruction manual

Satel CA-6 KLED-S user manual

Satel

Satel CA-6 KLED-S user manual

Evolution IQ plus 800 installation manual

Evolution

Evolution IQ plus 800 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Series A-286 Magnehelic®Gage Panel Mounting Flange
Specifications - Installation and Operating Instructions
Bulletin P-A-286
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: [email protected]
The new mounting flange can be used on any Dwyer Instruments, Inc.
gage that possesses a 4-1/2˝ (115 mm) diameter housing. The flange is
secured to the gage behind its bezel with three set screws. The set
screws hold the gage tight in place. The gage/flange can then be
attached to a surface or panel with a drill and the supplied mounting
screws. The flange’s three mounting holes follow the industry standard
mounting pattern. The flange is made of a robust plastic composite and
comes with three pre-installed set screws, an allen wrench for tighten-
ing and three flange mounting screws.
INSTALLATION
Cut out a circular hole using the template on this manual. The diameter
hole size depends on tightness of set screws securing the flange to the
gage. Typically, a sufficient flange tightness will produce a required
diameter cut-out between 5 1/16˝ – 5 1/8˝. See the included template to
locate on your panel this proper size diameter cut-out in relation to the
locations of the three mounting screws.
Next, alternating between the three set screws, use the included allen
wrench to turn each set screw 1/4 to 1/2 turns at a time to ensure an
even tightness so one screw doesn’t cause the flange to bow.
To properly secure flange to gage, 1 to 1.5 full revolutions of each set
screw will be required.
Last, install flange with secured gage to wall or panel using the three
included mounting screws.
11/16
[17.46]
1/2
[12.70]
(3) #6-32 X 3/16 [4.76] OP HOLES
EQUALLY SPACED ON A ø4-1/8 [104.78]
BOLT CIRCLE FOR PANEL MOUNTING
(3) ø11/32 [8.73] X 82˝ COUNTERSINK
ø3/16 [4.76] X THRU ON
A 5-17/32 [140.49]
BOLT CIRCLE FOR PANEL
MOUNTING WITH FLANGE
1/8 FEMALE NPT HIGH
PRESSURE CONNECTION
1-3/4
[44.45]
17/32
[13.49]
ø4-31/64
[113.90]
15/32
[11.91]
1019/32
[40.48]
15/32
[11.91] ø4-3/4
[120.65]
ø6-9/32
[159.54]
5/8
[15.88]
1/8 FEMALE NPT HIGH
PRESSURE CONNECTION
1/8 FEMALE NPT LOW
PRESSURE CONNECTION
1-1/4
[31.75]
1/8 FEMALE NPT LOW
PRESSURE CONNECTION
(3) #8-32 X 1/4˝ [6.35] LG
SET SCREWS EQUALLY SPACED
SPECIFICATIONS
Flange Materials: Plastic.
Weight: 2.3 oz (65 g).
INCLUDED ACCESSORIES
3 Pre-installed metal set screws
3 Mounting screws
1 Allen wrench
1 Instruction manual with mounting template
P-A-286:D-55 7/16/10 9:58 AM Page 1
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: [email protected]
©Copyright 2010 Dwyer Instruments, Inc. Printed in U.S.A. 7/10 FR# R1-443783-00 Rev. 2
(3) SURFACE MOUNTING
HOLE LOCATIONS
THRU HOLE FOR
PRESSURE PORTS
OUTSIDE DIAMETER OF FLANGE
(3) FLANGE MOUNTING
HOLE LOCATIONS
MOUNTING HOLE
DIMENSION FOR FLANGE
ø5-1/8 [130.18]
STANDARD MOUNTING
HOLE DIMENSION
FOR MAGNEHELIC GAGE
ø4-9/16 [115.89]
Flange Mounting Template