Series A-286 Magnehelic®Gage Panel Mounting Flange
Specifications - Installation and Operating Instructions
Bulletin P-A-286
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: [email protected]
The new mounting flange can be used on any Dwyer Instruments, Inc.
gage that possesses a 4-1/2˝ (115 mm) diameter housing. The flange is
secured to the gage behind its bezel with three set screws. The set
screws hold the gage tight in place. The gage/flange can then be
attached to a surface or panel with a drill and the supplied mounting
screws. The flange’s three mounting holes follow the industry standard
mounting pattern. The flange is made of a robust plastic composite and
comes with three pre-installed set screws, an allen wrench for tighten-
ing and three flange mounting screws.
INSTALLATION
Cut out a circular hole using the template on this manual. The diameter
hole size depends on tightness of set screws securing the flange to the
gage. Typically, a sufficient flange tightness will produce a required
diameter cut-out between 5 1/16˝ – 5 1/8˝. See the included template to
locate on your panel this proper size diameter cut-out in relation to the
locations of the three mounting screws.
Next, alternating between the three set screws, use the included allen
wrench to turn each set screw 1/4 to 1/2 turns at a time to ensure an
even tightness so one screw doesn’t cause the flange to bow.
To properly secure flange to gage, 1 to 1.5 full revolutions of each set
screw will be required.
Last, install flange with secured gage to wall or panel using the three
included mounting screws.
11/16
[17.46]
1/2
[12.70]
(3) #6-32 X 3/16 [4.76] OP HOLES
EQUALLY SPACED ON A ø4-1/8 [104.78]
BOLT CIRCLE FOR PANEL MOUNTING
(3) ø11/32 [8.73] X 82˝ COUNTERSINK
ø3/16 [4.76] X THRU ON
A 5-17/32 [140.49]
BOLT CIRCLE FOR PANEL
MOUNTING WITH FLANGE
1/8 FEMALE NPT HIGH
PRESSURE CONNECTION
1-3/4
[44.45]
17/32
[13.49]
ø4-31/64
[113.90]
15/32
[11.91]
1019/32
[40.48]
15/32
[11.91] ø4-3/4
[120.65]
ø6-9/32
[159.54]
5/8
[15.88]
1/8 FEMALE NPT HIGH
PRESSURE CONNECTION
1/8 FEMALE NPT LOW
PRESSURE CONNECTION
1-1/4
[31.75]
1/8 FEMALE NPT LOW
PRESSURE CONNECTION
(3) #8-32 X 1/4˝ [6.35] LG
SET SCREWS EQUALLY SPACED
SPECIFICATIONS
Flange Materials: Plastic.
Weight: 2.3 oz (65 g).
INCLUDED ACCESSORIES
3 Pre-installed metal set screws
3 Mounting screws
1 Allen wrench
1 Instruction manual with mounting template
P-A-286:D-55 7/16/10 9:58 AM Page 1
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: [email protected]
©Copyright 2010 Dwyer Instruments, Inc. Printed in U.S.A. 7/10 FR# R1-443783-00 Rev. 2
(3) SURFACE MOUNTING
HOLE LOCATIONS
THRU HOLE FOR
PRESSURE PORTS
OUTSIDE DIAMETER OF FLANGE
(3) FLANGE MOUNTING
HOLE LOCATIONS
MOUNTING HOLE
DIMENSION FOR FLANGE
ø5-1/8 [130.18]
STANDARD MOUNTING
HOLE DIMENSION
FOR MAGNEHELIC GAGE
ø4-9/16 [115.89]
Flange Mounting Template
P-A-286:D-55 7/16/10 9:58 AM Page 2

Popular Control Panel manuals by other brands

tau K123M installation guide

tau

tau K123M installation guide

CPflight MCP737PRO3 manual

CPflight

CPflight MCP737PRO3 manual

DSC MAXSYS PC4020NK System manual

DSC

DSC MAXSYS PC4020NK System manual

CAME ZLX24MA installation manual

CAME

CAME ZLX24MA installation manual

t.a.c. Xenta OP Handbook

t.a.c.

t.a.c. Xenta OP Handbook

Profelmnet 3033 manual

Profelmnet

Profelmnet 3033 manual

LinkAYL LK-UP22 Series manual

LinkAYL

LinkAYL LK-UP22 Series manual

GRASS VALLEY JUPITER CONTROL PANEL LD16 - datasheet

GRASS VALLEY

GRASS VALLEY JUPITER CONTROL PANEL LD16 - datasheet

DPLUS CLIMA24 manual

DPLUS

DPLUS CLIMA24 manual

Risco GardTec 350+ installation instructions

Risco

Risco GardTec 350+ installation instructions

AdvanteX VCOM AX20-A1 installation manual

AdvanteX

AdvanteX VCOM AX20-A1 installation manual

GE Security Simon XT user guide

GE Security

GE Security Simon XT user guide

INIM Electronics SmartLine Series Installation and programming manual

INIM Electronics

INIM Electronics SmartLine Series Installation and programming manual

ALL TUBE-LIGHT operating guide

ALL

ALL TUBE-LIGHT operating guide

WURM ANI-2F1 manual

WURM

WURM ANI-2F1 manual

Piusi MC BOX Use and maintenance manual

Piusi

Piusi MC BOX Use and maintenance manual

Pulsar AWO 300 Assembly instructions

Pulsar

Pulsar AWO 300 Assembly instructions

tau D703 installation guide

tau

tau D703 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.