manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Dwyer Instruments
  6. •
  7. Other
  8. •
  9. Dwyer Instruments DW-USB-1-HT series Operating instructions

Dwyer Instruments DW-USB-1-HT series Operating instructions

Other Dwyer Instruments Other manuals

Dwyer Instruments BDL-1 Installation and operating instructions

Dwyer Instruments

Dwyer Instruments BDL-1 Installation and operating instructions

Dwyer Instruments HTDL-10 Supplement

Dwyer Instruments

Dwyer Instruments HTDL-10 Supplement

Dwyer Instruments DW-WIFI  Series User manual

Dwyer Instruments

Dwyer Instruments DW-WIFI Series User manual

Popular Other manuals by other brands

Opticon EduMic Compatibility guide

Opticon

Opticon EduMic Compatibility guide

Kessil A360W owner's manual

Kessil

Kessil A360W owner's manual

TEFAL ULTRA COMPACT MIXER manual

TEFAL

TEFAL ULTRA COMPACT MIXER manual

Martin Audio WS18X - SCHEMATICS manual

Martin Audio

Martin Audio WS18X - SCHEMATICS manual

Hendrickson AR2 series Service instructions

Hendrickson

Hendrickson AR2 series Service instructions

GO Industries 38017 installation instructions

GO Industries

GO Industries 38017 installation instructions

Cissell 30LBCMAN2 manual

Cissell

Cissell 30LBCMAN2 manual

RIDGID K-60SP manual

RIDGID

RIDGID K-60SP manual

Gage Bilt GB751SH-5 Original instructions

Gage Bilt

Gage Bilt GB751SH-5 Original instructions

OVE SIERRA 60 installation manual

OVE

OVE SIERRA 60 installation manual

ReelCraft 7800 OLB21 operating instructions

ReelCraft

ReelCraft 7800 OLB21 operating instructions

Body Armor 4x4 ECO-SERIES user manual

Body Armor 4x4

Body Armor 4x4 ECO-SERIES user manual

ROBLIN DROP Dimensions

ROBLIN

ROBLIN DROP Dimensions

EMG EMG-ACB BARREL Installation information

EMG

EMG EMG-ACB BARREL Installation information

MiniSolar MT-150 Assembling Guide

MiniSolar

MiniSolar MT-150 Assembling Guide

Parkside PSZ 250 B2 Operation and safety notes

Parkside

Parkside PSZ 250 B2 Operation and safety notes

ABB REM 610 Technical reference manual

ABB

ABB REM 610 Technical reference manual

Tyent ACE-13 user manual

Tyent

Tyent ACE-13 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

eries DW-U B-1-HT High Temperature U B Data Logger
pecifications and Operating Instructions
DLR-DW-U B-1-HT
DWYER IN TRUMENT , INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U. .A. Fax: 219/872-9057 e-mail: [email protected]
Model DW-U B-1-HT High Temperature U B Data Logger allows
users to monitor temperatures up to 257°F (125°C). The rigid, stainless
steel enclosure protects the sensor against corrosion, impact, and water
ingress. With the easy to install Windows®based software, parameters
can be configured to work in many applications. Data can be
downloaded by plugging the data logger directly into a C’s USB port,
with no cable required. Downloaded data can then be graphed, printed,
or exported to other spreadsheet applications.
OPERATING IN TRUCTION
Battery Installation
Before using the data logger, you will need to insert the 3.6 V 2/3 AA high
temperature battery provided, following the instructions below:
1. Use a coin to turn the battery cover counter-clockwise.
2. Remove the battery cover.
3. Insert battery, taking notice of the indicated polarities.
4. Replace battery cover. Use a coin to turn the cover clockwise until
securely tightened.
PECIFICATION
Temperature Range: -40 to 257°F (-40 to 125°C).
Temperature Accuracy: ±1°F (±0.5°C).
Temperature Resolution: 0.2°F (0.1°C).
Memory ize: 32,510 readings.
ampling Mode: Continuous or stop on memory full.
ampling Rate: Selectable from 1 sec to 12 hours.
Computer Requirements: Windows® 2000, Windows® X , Windows
Vista®, and Windows® 7; 32 or 64-bit operating systems.
Power Requirements: 3.6 V 2/3 AA lithium battery (included).
Battery Life: Approximately 1 to 3 years.
Housing: 316 SS.
Enclosure Rating: I 67/NEMA 4X.
Alarms: rogrammable high/low.
Interface: USB port.
Weight: 4.6 oz (130.4 g).
Agency Approvals: CE, RoHS.
4-3/8
[111.13]
Ø25/32
[19.84]
ONLY USE SPECIFIED BATTERY
DW-USB-1-HT
HIGH TEMPERATURE DATA LOGGER
RANGE: -40 TO 125°C (-40 TO 257°F)
Windows® and Windows Vista® are registered trademarks of Microsoft Corporation.
DWYER IN TRUMENT , INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U. .A. Fax: 219/872-9057 e-mail: [email protected]
©Copyright 2011 Dwyer Instruments, Inc. rinted in U.S.A. 8/11 FR# R6-443584-10
OFTWARE IN TALLATION
1. Insert the software CD into the CD drive of your computer. If the CD
does not automatically load, navigate to the CD and double click
“Setup”.
2. Follow the on screen instructions to complete software installation.
Data Logger etup
The previously installed software can be used to setup the data logger.
Use the options tab to begin logging, download data from a running log, or
view previously saved data. The status of the attached data logger can
also be checked.
1. Ensure the battery is correctly installed.
2. Insert the data logger into an available USB port on your computer.
3. Double click the “EasyLog USB” icon on your desktop.
etup/ tarting Data Logger
1. To configure the device and begin logging, click the “set up and start the
USB Data Logger” button. Follow the on screen instructions.
2. Assign the data logger a name.
3. Select the appropriate input type and engineering units.
4. Set up the sampling rate.
5. Set up alarm values.
6. Select desired date for the date you want the logger to start logging.
7. Click finish.
8. Once the device is configured and you have started logging, remove the
device from the computer and place the USB cap back on. The device
is now ready to be used.
topping Data Logger and Download data
1. When finished taking data, remove the USB cover, plug the device into
the computer, and click the “stop the USB Data Logger and download
data” button.
Exporting Data
1. Open the saved data by pressing “view previously saved data”.
2. Select the data file you wish to export.
3. After the graph of the data opens in a separate window, click export.
4. Excel will open with a tab of the graph and a tab of the data.
MAINTENANCE/REPAIR
Upon final installation of the Series DW-USB-1-HT, no routine maintenance
is required. The Series DW-USB-1-HT, is not field serviceable and should
be returned if repair is needed. Field repair should not be attempted and
may void warranty.
WARRANTY/RETURN
Refer to “Terms and Conditions of Sales” in our catalog and on our website.
Contact customer service to receive a Return Goods Authorization number
before shipping the product back for repair. Be sure to include a brief
description of the problem plus any additional application notes.
Dispose of used batteries promptly and keep away from
children.
NOTICE
Windows®2000, Windows®X, Windows Vista®, Windows®7,
32/64-bit operating system is required for software installation.
NOTICE
Faster sampling rates will yield a shorter battery life.
NOTICE