eries DW-U B-1-HT High Temperature U B Data Logger
pecifications and Operating Instructions
DLR-DW-U B-1-HT
DWYER IN TRUMENT , INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U. .A. Fax: 219/872-9057 e-mail: [email protected]
Model DW-U B-1-HT High Temperature U B Data Logger allows
users to monitor temperatures up to 257°F (125°C). The rigid, stainless
steel enclosure protects the sensor against corrosion, impact, and water
ingress. With the easy to install Windows®based software, parameters
can be configured to work in many applications. Data can be
downloaded by plugging the data logger directly into a C’s USB port,
with no cable required. Downloaded data can then be graphed, printed,
or exported to other spreadsheet applications.
OPERATING IN TRUCTION
Battery Installation
Before using the data logger, you will need to insert the 3.6 V 2/3 AA high
temperature battery provided, following the instructions below:
1. Use a coin to turn the battery cover counter-clockwise.
2. Remove the battery cover.
3. Insert battery, taking notice of the indicated polarities.
4. Replace battery cover. Use a coin to turn the cover clockwise until
securely tightened.
PECIFICATION
Temperature Range: -40 to 257°F (-40 to 125°C).
Temperature Accuracy: ±1°F (±0.5°C).
Temperature Resolution: 0.2°F (0.1°C).
Memory ize: 32,510 readings.
ampling Mode: Continuous or stop on memory full.
ampling Rate: Selectable from 1 sec to 12 hours.
Computer Requirements: Windows® 2000, Windows® X , Windows
Vista®, and Windows® 7; 32 or 64-bit operating systems.
Power Requirements: 3.6 V 2/3 AA lithium battery (included).
Battery Life: Approximately 1 to 3 years.
Housing: 316 SS.
Enclosure Rating: I 67/NEMA 4X.
Alarms: rogrammable high/low.
Interface: USB port.
Weight: 4.6 oz (130.4 g).
Agency Approvals: CE, RoHS.
4-3/8
[111.13]
Ø25/32
[19.84]
ONLY USE SPECIFIED BATTERY
DW-USB-1-HT
HIGH TEMPERATURE DATA LOGGER
RANGE: -40 TO 125°C (-40 TO 257°F)
Windows® and Windows Vista® are registered trademarks of Microsoft Corporation.
DWYER IN TRUMENT , INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U. .A. Fax: 219/872-9057 e-mail: [email protected]
©Copyright 2011 Dwyer Instruments, Inc. rinted in U.S.A. 8/11 FR# R6-443584-10
OFTWARE IN TALLATION
1. Insert the software CD into the CD drive of your computer. If the CD
does not automatically load, navigate to the CD and double click
“Setup”.
2. Follow the on screen instructions to complete software installation.
Data Logger etup
The previously installed software can be used to setup the data logger.
Use the options tab to begin logging, download data from a running log, or
view previously saved data. The status of the attached data logger can
also be checked.
1. Ensure the battery is correctly installed.
2. Insert the data logger into an available USB port on your computer.
3. Double click the “EasyLog USB” icon on your desktop.
etup/ tarting Data Logger
1. To configure the device and begin logging, click the “set up and start the
USB Data Logger” button. Follow the on screen instructions.
2. Assign the data logger a name.
3. Select the appropriate input type and engineering units.
4. Set up the sampling rate.
5. Set up alarm values.
6. Select desired date for the date you want the logger to start logging.
7. Click finish.
8. Once the device is configured and you have started logging, remove the
device from the computer and place the USB cap back on. The device
is now ready to be used.
topping Data Logger and Download data
1. When finished taking data, remove the USB cover, plug the device into
the computer, and click the “stop the USB Data Logger and download
data” button.
Exporting Data
1. Open the saved data by pressing “view previously saved data”.
2. Select the data file you wish to export.
3. After the graph of the data opens in a separate window, click export.
4. Excel will open with a tab of the graph and a tab of the data.
MAINTENANCE/REPAIR
Upon final installation of the Series DW-USB-1-HT, no routine maintenance
is required. The Series DW-USB-1-HT, is not field serviceable and should
be returned if repair is needed. Field repair should not be attempted and
may void warranty.
WARRANTY/RETURN
Refer to “Terms and Conditions of Sales” in our catalog and on our website.
Contact customer service to receive a Return Goods Authorization number
before shipping the product back for repair. Be sure to include a brief
description of the problem plus any additional application notes.
Dispose of used batteries promptly and keep away from
children.
NOTICE
Windows®2000, Windows®X, Windows Vista®, Windows®7,
32/64-bit operating system is required for software installation.
NOTICE
Faster sampling rates will yield a shorter battery life.
NOTICE

Other Dwyer Instruments Other manuals

Dwyer Instruments BDL-1 Installation and operating instructions

Dwyer Instruments

Dwyer Instruments BDL-1 Installation and operating instructions

Dwyer Instruments HTDL-10 Supplement

Dwyer Instruments

Dwyer Instruments HTDL-10 Supplement

Dwyer Instruments DW-WIFI  Series User manual

Dwyer Instruments

Dwyer Instruments DW-WIFI Series User manual

Popular Other manuals by other brands

GRASS VALLEY FIBER MEDIA CONVERTER DEVICES datasheet

GRASS VALLEY

GRASS VALLEY FIBER MEDIA CONVERTER DEVICES datasheet

Witt PATBOX instruction manual

Witt

Witt PATBOX instruction manual

Fichet-Bauche NEVO Quick user guide

Fichet-Bauche

Fichet-Bauche NEVO Quick user guide

DJM Suspension RK2007 installation instructions

DJM Suspension

DJM Suspension RK2007 installation instructions

Rixen TX-600N instruction manual

Rixen

Rixen TX-600N instruction manual

Hortitek Defender Series instruction manual

Hortitek

Hortitek Defender Series instruction manual

Axent PRIMUS user manual

Axent

Axent PRIMUS user manual

Kalia AKCESS Installation instructions / warranty

Kalia

Kalia AKCESS Installation instructions / warranty

Kalia KONTACT Series Installation instructions / warranty

Kalia

Kalia KONTACT Series Installation instructions / warranty

EAGO DZ959F8 installation instructions

EAGO

EAGO DZ959F8 installation instructions

Mincey Marble Napoli Series installation instructions

Mincey Marble

Mincey Marble Napoli Series installation instructions

TradeQuip 1146T owner's manual

TradeQuip

TradeQuip 1146T owner's manual

NEFF D 26 Series installation instructions

NEFF

NEFF D 26 Series installation instructions

BINZEL-ABICOR BRS-LCi SPS operating instructions

BINZEL-ABICOR

BINZEL-ABICOR BRS-LCi SPS operating instructions

Pepperl+Fuchs RAPID EXCHANGE 1002 Series Installation & operation manual

Pepperl+Fuchs

Pepperl+Fuchs RAPID EXCHANGE 1002 Series Installation & operation manual

aquaHabitats MicroHabitat 30 Instructions for use

aquaHabitats

aquaHabitats MicroHabitat 30 Instructions for use

Kohler K-4918 installation guide

Kohler

Kohler K-4918 installation guide

Chipkin Modbus CAS2500-01 user manual

Chipkin

Chipkin Modbus CAS2500-01 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.