Caution
1. The product must be installed by professional technicians and the power supply must be cut off before installation.
2. The installation wiring must be at least 0.75mm2and wired in accordance with the latest IEE electrical regulations
or the national requirements.
3. Do not touch the electronic circuit and its components.
4. Contact an authorised technical service centre for any repairs required and use only original spare parts.
5. Do not touch LEDs while installing or maintaining.
6. The LED light source can not be replaced.
RoHS
SAA
IP20
1. Cut off the main power first
2. Don’t touch LEDs while maintaining or cleaning
3. Don't use chemicals to clean the fixture.
Environmental protection: waste electrical products should not be disposed of with household waste. Please recycle
where facilities exist. Check with your local authority or retailer for recycling advice.
Maintenance
Detection Pattern
ceiling mounting pattern (m)
6m
12m
wall mounting pattern (m)
9m
4m
Sensor On/off(dimming) Setting Options
Sensitivity can be adjusted by selecting the combination
on the DIP switches for different applications.
I – 5s
II – 90s
III – 3min
IV – 10min
I – 0s
II – 10s
III – 10min
IV – +
Hold-time refers to the time period that the light remains
100% on if no more movement is detected.
This is the time period that the light remains at a low level
before it is completely turned off.
I – 100%
II – 50%
100%
50%
1
6 7
0s
10s
10min
+
I – Disable
II – 50Lux
III – 10Lux
IV – 2Lux
Daylight sensor
Different daylight threshold can be preset on DIP switches.
Light will always turn on upon movement if daylight sensor
is disabled.
Stand-by dimming level
Light can be dimmed to different levels after hold-time.
I – 10%
II – 30%
10%
30%
8
Disable
50Lux
10Lux
2Lux
4 5
5s
90s
3min
10min
2 3
Sensitivity
Stand-by period
Hold-time
2~50Lux
Stand-by period
0s~+
8
Hold-time
5s~30min
ceiling mounting pattern (m)
6m
12m
Wiring: