The SimTach A is
an
industrial quality, digital voltmeter
which provides a calibrated speed readoutfrom a variety
of
signal sources. Its wide range
of
Inputs allows inter-
face to process signals, DC tachometers and motor
drives. An optionaldigitalcalibratoroffersprecisescaling
while maintaining accuracy. Easyinstallation and convi-
enientswitchselectionsmake
itthe
best
choice
for
speed
indicator applications.
FEATURES
• Large, ±
4-1/2
Digit
LED
Display
•
Switch
Selectable 20, 200,
and
600 VDC
Ranges
• Selectable
Display
Decimal
Point
•
Fast
or
Slow
Display
Update
Rate
• Sealed
NEMA
1
Front
Panel
-.-
...
-.------
_.-------_
...
__
._.
_.-
-.---~-.-
-_.
CONDENSED SPECIFICATIONS
•
0,1
%
Accuracy
• Optlon,,1
O.XXX
Digital
Calibrator
• s 71
ppm
/ °C. Temperature
Drift
•
)(,
to
)(,xxxx: Decimal
Point
Range
•
1/1
DIN
Panel
Cutout
•
11i
or
230
VAC
Operation
INDEX
TO
CONTENTS
Op~rm:ion
Applj§ations
Inst§lIation
Wirin.!l
Sp~§jfications
Orq~ring
Information
DYNIlPIlR
page 2
page 2
page 3
page 3
page 4
page 4
OPERATION
Input Range Selection
The inputsignal is applied to a precision resistorvoltage
divider network which scales the signal down to the 2
VDC internal range. The 20, 200 and 600 volt range
switches provide +10, +100 and +1000 selections.
Gain
Adjust
Pot
(ST
AxO)
Thepotentiometerand amplifierprovide gainadjustment
to calibrate the display to readout
in
engineering units.
Digital Calibrator (STAx1)
The divided input
is
routed through a digital-to-analog
converter (DAC),which multiplies the signal bythescale
factor set on the BCD switches as
O.XXX
. (Note that a
setting of 0.000 =Calibration of 1.)
Analog-to-Digital
Converter
The ADC uses dual-slope conversion and auto-zero
circuitry to povide a full
4-1/2
digit range. A selectable
clock source allows fast or slow display updates to meet
differing application requirements.
LED Display
The
4-1/2
digitpovides asignforinputsthat range below
zero, and selectable decimal point displays.
APPLICATIONS
Actual
Speed
Indicator
Using
DC
Tach
Feedback
I
/
'\
IIIII
DC
Drive
,If
~
OCT,,,,
Motor
DC
Tachometer Feedback
SimTach
A
To
provide a calibrated speed readout of motor RPM, a
DC
tachometerwith
a1
0volt-per-thousand RPM output
is
mounted to the motor. The maximum motorspeed
is
7200 RPM, for which the tachometer will generate an
output of 72 volts DC.
The 200 VDC input range is selected; no decimal point
display
is
chosenfor RPM readout. The displaywill read:
72
volts input x 20,000 max. display =7200
200 volt range
No adjustment
of
the gain adjust pot is needed (factory
set for gain of 1).
Vin
Page 2
RANGE
Vi
nit
0
20
VOLT
'00
VOLT
-
£23'-15
I
Vin/l00
'.lin/1ooD
r----------------------
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
______
-----------------~
OPTIONAL
DIGITAL
CALIBRATOR
SlmTach A Block Diagram
Actual
Speed
Indicator
Using
Motor
Armature
Voltage
+
Armature
Motor
Armature Voltage Feedback
ANALOG
TO
DIGITAL
CONVERTER
SimTach
A
fAST
An 480voltDC motor
is
drivinga conveyoratamaximum
speed
of
360 inches per minute.
The
600
VDC range
is
needed, and a
.x
decimal point
display is selected. With no calibration, the display is:
480
volts input x 20,000 max. display =480.0
2000
volt range
The calibrator
is
calculated by the folrmula:
360.0 desired =0.750
480.0 expected
The
BCD
switches are set to 0.750 to calibrate the unit.
INSTALLATION
1.
PANEL MOUNTING
Make a panel cutout as shown below (right). Affix the
adhesive gasket (for watertight seal, if required) to the
panel. Remove the panel straps and slide the unit
through the cutout. Slide the panel straps into the
enclosure guides. Secure the unit by tightening the hex
washer head screws into the guides.
~
I
r-
panel
thickness
1/18"
to
1/4"
I
1
< depth
behind
bezel
1<-----
5.88
144.3mm
WIRING
2.
INPUT POWER
(For models
STA-S-x
only: Select
115
or 230 VAC
operation with a slotted screwdriverthroughtthe cutout.
Unit
is
factory set for 230 VAC.)
Supply
AC
powerthrough a separtely fused circuit. Unit
requires externalfusing rated 1/4
A.
for
115
VAC or1/8
A.
for 230 VAC, slow blow type. Connect terminal
#3
to
BUILDING GROUND!
3. SIGNAL INPUT
Connect the signal input, noting polarity of the + and -
terminals, using shielded wiring with the shield con-
nected to terminal:':'3.
Select one of the three input voltage ranges on the DIP
switches, accordingtothemaximum signalinputvoltage.
DO NOT EXCEED 600 VDC!
VAC@8VA
f>f»
xl:!~
5G/8OHz
1liI1i~'II\~
'l'f?ilFUS"
WIllI
I~lt:il
INPUT
•
DEC.
roT.
:11:
U
RANGE
:..'
:..
UPDATE
HAlE
~
i !
1 2 3
Page 3
CONFIGURAllON SWITCHES
ijA(liU
TI
1.78~/+.04
45~/+1
mm
L--------I1L
f.oIl<~----
3.58~/+.04
91·0/+1
mm
N C
~
~
~
1 2 3
I
allow
I
-------'>~.
::.
~
each side
between
cutouts
115/230VAC,
SO/60
Hz,
6VA
SIGNALCOMMON
SIGNAL INPUT
C
Z
CJ
,
3!:
+
3!:
SPECIFICATIONS Page 4
Input Power:
Display:
Decimal Point:
95 to 130 VAC, 50/60 Hz,
or
190to
260
VAC, 50/60 Hz, 6
VA
± 4
-1/2
Digit, 0.56" Red LED
Switch Selectable XXXXX. to
X.XXXX
Scale Factor Range:
Gain Adjust Pot:
Digital Calibrator:
Accuracy:
Stability:
5% to 200%
0.001 to 0.999
(0.000 =Calibration
of
1)
±0.1% -0/+1 Digit
Display Update Rate: Switch Selectable Operating Temperature: 0 to +50 °C. (32 to +122 of.)
Fast:
Slow: 2
Hz
(2
times persecond)
0.5 Hz (every
two
seconds) Dimensions:
Overall: 1.98" x 3.78" x 6.03"
Overvoltage Indication: Display FlashesAll
"O's"
50 mm x 96 mm x 150 mm
1.78" x 3.58" (-0/+0.04")
Cutout:
Signal Input Range: Switch Selectable 45 mm x
91
mm
(-0/+1 mm)
1/16" to 1/4"
o
to
± 20/200/600 VDC Panel Thickness:
Panel Depth: 5.68" (144 mm)
Weight: 1.4Ibs.
ORDERING INFORMATION
MODEL
STAOO
STAEO
STASO
DESCRIPTION
SimTach A Analog Input Speed Indicator, 115
VAC
Operation
SimTach A Analog Input Speed Indicator, 230
VAC
Operation
SimTach A Analog Input Speed Indicator, 115/230VAC Selectable Operation
SimTach A Analog Input Speed Indicator with Digital Calibration, 115
VAC
Operation
SimTach A Analog Input Speed Indicator with Digital Calibration, 230
VAC
Operation
STA01
STAE1
STAS1 SimTach A Analog Input Speed Indicator with Digital Calibration, 115/230VAC Selectable Operation
WARRANTY
Standard products manufactured by
the
Companyarewarranted
to
befree from defects inworkmanship and material
for
aperiodofoneyearfromthedate
of
shipment,and productswhich aredefectiveinworkmanshipormaterialwill be repaired
or
replaced, attheoption
ofthe
Company, atnochargetotheBuyer. Final determinationas
to
whethera productis actually
defective rests with the Company. The obligation of the Company hereunder shall be limited solely
to
repair
and
replacement
of
products that fall within the foregoing limitations, and shall be conditioned upon receipt by the Company
of
written notice of any alleged defects
or
deficiency promptly after discoverywithin the warranty period, and
in
the
case
of components or units purchased by the Company, the obligation
of
the Company shall not exceed the settlement
that
the Company is able to obtain from the supplierthereof.
No
products shall be returned
to
the Company without its
prior
consent. Products which the Company consents to have returned shall be shipped F.O.B. the Company's factory.
The
Company cannot assume responsibility
or
accept invoices for unauthorized repairs to its components, even
though
defective. The life ofthe products of
the
Company depends, to a large extent, upon thetype ofusagethereof, and
THE
COMPANY MAKES NO WARRANTYAS TO FITNESS OF ITS PRODUCTS FOR SPECIFICAPPLICATIONS
BY
THE
BUYER NOR AS
TO
PERIOD
OF
SERVICE UNLESS THE COMPANY SPECIFICALLY AGREES OTHERWISE
IN
WRITING AFTER THE PROPOSED USAGE HAS BEEN MADE KNOWN TO
IT.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU
OF
ALL OTHER WARRANTIES EXPRESSED
OR
IMPLIED, INCLUDING, BUT
NOT
LIMITED TO ANY WARRANTY
OF
MERCHANTABILITY OR
OF
FITNESS FOR A
PARTICULAR PURPOSE.
SERVICE:
Include:
Ifthis product requires service, call Dynapar Corp.
for
an
RMA
(Return Material Authorization)
number, pack it in a sturdy carton and ship prepaid to: Service Dept. at address below.
1. Description
of
problem 3. Purchase order number
2. Name of responsible person
4.
Return shipping instructions
DANAHER
CONTROLS
• 2100
W.
Broad St., P.O. Box 368, Elizabethtown, NC 28337 TEL: (847) 662-2666 FAX: (847}662-6633
160 0250 0132 Printed
in
U.S.A. April 20,
1992

This manual suits for next models

5

Popular Touch Panel manuals by other brands

Moxa Technologies MPC-2190X Hardware manual

Moxa Technologies

Moxa Technologies MPC-2190X Hardware manual

RaycoWylie i4000 instruction manual

RaycoWylie

RaycoWylie i4000 instruction manual

Hirschmann Mentor EI65 Operator's manual

Hirschmann

Hirschmann Mentor EI65 Operator's manual

Aplex ViTAM-8 Series user manual

Aplex

Aplex ViTAM-8 Series user manual

Extron electronics SMK 2 installation guide

Extron electronics

Extron electronics SMK 2 installation guide

Ltech DX8 manual

Ltech

Ltech DX8 manual

Topway LMK070DDCFWD-NNA user manual

Topway

Topway LMK070DDCFWD-NNA user manual

Advantech TPC-1071H user manual

Advantech

Advantech TPC-1071H user manual

Keba OP 460-LD/A Project engineering manual

Keba

Keba OP 460-LD/A Project engineering manual

Excell PCH3 user manual

Excell

Excell PCH3 user manual

Panasonic TY-TP42P30K  () operating instructions

Panasonic

Panasonic TY-TP42P30K () operating instructions

powersoft WM Touch installation guide

powersoft

powersoft WM Touch installation guide

Armacost Lighting 733121 quick start guide

Armacost Lighting

Armacost Lighting 733121 quick start guide

Unipulse DeviceNet F381A Operation manual

Unipulse

Unipulse DeviceNet F381A Operation manual

Cybernet CyberMed M156S user manual

Cybernet

Cybernet CyberMed M156S user manual

Eldes EWKB5 installation guide

Eldes

Eldes EWKB5 installation guide

AllSee Technologies Freestanding Infrared Multi Touch Screen... user manual

AllSee Technologies

AllSee Technologies Freestanding Infrared Multi Touch Screen... user manual

Touchboards ACTIVEPANEL TOUCH installation guide

Touchboards

Touchboards ACTIVEPANEL TOUCH installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.