6
Maintenance Guidelines
• Keep your compressor clean. Any excess dust and debris on motor or air
intake may signicantly shorten the life of the compressor.
• Diusers may need regular cleaning in certain water conditions. This may be
every two to ve years.
• Compressors may need to be rebuilt if running but no longer “pumping air.”
Contact your EasyPro dealer for compressor rebuild kits.
• If lines become frozen, a small amount of denatured alcohol can be run down
the frozen line to thaw it out. The small amount of alcohol will not harm sh or
biological processes in your pond.
After one or two years of operation, you will possibly notice a sudden drop in air
bubbles. This is a sign the compressor needs new piston cup or vanes. Rebuild
kits are available to restore like-new performance. Be sure to keep the air lter
clean. Filters can be washed in soapy water. Replacement lters are available.
Kit Replacement Compressor
Part # Compressor* Filter/Element Repair Kits
PA34 ERP25 ERPF1/ERPF12E ERP25K
PA66 ERP50 ERPF1/ERPF12E ERP50K
PA86 ERP75 ERPF2/ERPF12E ERP75K
PA90 ERP75 ERPF2/ERPF12E ERP75K
*Compressors all carry a two year warranty from date of purchase. See compressor instructions
for warranty details.
Troubleshooting
Compressor Troubleshooting
Low High Compressor Excess
Pressure Pressure Overheating Noise Cause and Solution
• • Dirty air lter, clean or replace
• Valves closed too much, open valves
• • Worn piston cup, rebuild compressor
• Plugged/frozen tubing, inspect and repair
• • Leaky tubing or check valve, inspect and repair
Compressor will not start • Wrong voltage, check power source
Compressor will not start • Miswired electrical components, check wiring
Diffuser Troubleshooting
Low High Uneven Burping
Air Flow Air Flow Air Flow Bubbles Cause and Solution
• • Leak in system, check connections and repair
• • • Manifold not set correctly, adjust placement
• Damaged or torn membrane, replace
• Compressor issue, see above