1.1 Field of applications........................................................................................................................................... 4
1.2 Symbols used in this manual............................................................................................................................. 4
1.3 Conventions used in this document.................................................................................................................. 5
2 FIGURES AND SPECIFICATIONS ...........................................................................................................6
3 CAUTIONS.............................................................................................................................................. 11
3.1 Operating environment and restrictions ..........................................................................................................11
3.2 Protection from electric shock .........................................................................................................................12
3.3 Warning decals and rating plate.......................................................................................................................12
4 GENERAL DESCRIPTION ......................................................................................................................13
4.1 xStorage Home 3P high voltage hybrid inverter ..............................................................................................13
4.2 Operating modes .............................................................................................................................................13
4.3 HV Lithium-ion battery .....................................................................................................................................17
4.4 Touch-screen control panel...............................................................................................................................18
5 ELECTRICAL CONNECTIONS ...............................................................................................................19
5.1 Wi-Fi connection ..............................................................................................................................................19
5.2 LAN connection ...............................................................................................................................................19
5.3 System switching on........................................................................................................................................19
5.4 System switching off .......................................................................................................................................19
6 CONTROL PANEL ..................................................................................................................................20
6.1 General information ........................................................................................................................................ 20
6.2 IP Protection class rating ................................................................................................................................ 21
7 SYSTEM PROGRAMMING....................................................................................................................23
7.1 Main menu structure and system navigation .................................................................................................. 23
7.2 Main menu ...................................................................................................................................................... 24
7.3 Login/Logout Menu ......................................................................................................................................... 25
7.4 Charts menu.................................................................................................................................................... 26
7.5 Info menu ........................................................................................................................................................ 29
7.6 Export menu.................................................................................................................................................... 31
7.7 Setting menu ................................................................................................................................................... 32
7.8 System update ................................................................................................................................................ 41
8 MONITORING SYSTEM ........................................................................................................................42
8.1 General information ........................................................................................................................................ 42
8.2 Getting started – Preparing the Wi-Fi/LAN connection ................................................................................... 42
8.3 Eaton web portal access................................................................................................................................. 46
9 MAINTENANCE ..................................................................................................................................... 51
9.1 General information ........................................................................................................................................ 51
9.2 Disposal .......................................................................................................................................................... 51
10 TROUBLESHOOTING ............................................................................................................................52
11 TECHNICAL DATA..................................................................................................................................57
9.1 Rating plate..................................................................................................................................................... 57
9.2 Technical datasheet ......................................................................................................................................... 57
12 CONTACT SUPPORT INFORMATION ..................................................................................................57
13 WARRANTY ...........................................................................................................................................57

3
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
1. Introduction
Thank you for purchasing xStorage Home 3P energy storage system.
Before you start
This manual contains important instructions that must be followed during the installation, operation and maintenance
of the xStorage Home 3P system. All instructions must be read before installing and operating the equipment. This
manual should be retained for future reference. Please note that the xStorage Home 3P system must only be installed by
Eaton certified personnel, i.e. an Eaton technical support representative or an Eaton certified installer. There are no user
serviceable parts inside the xStorage Home 3P system. Failure to observe the above will void the guarantee provided and
Eaton cannot be held legally accountable.
This product is intended for residential application only. The contents of this manual are the copyright of the publisher and
may not be reproduced (even in extracts) without the prior written approval of Eaton Corporation. While every care has
been taken to ensure the accuracy of the information contained in this manual, Eaton assumes no liability for any error
or omission. Eaton reserves the right to modify the designs of its products. The unauthorized copying and lending of this
manual is prohibited.
Technical disclaimer
In line with our goal to continuously improve the products and the customer service we provide, all specifications
contained in this document are subject to change without notice. All drawings, descriptions or illustrations contained
in this document serve to provide a clear overview and/or technical explanation of the present product and its various
components and accessories.
Legal entity
Eaton Industries manufacturing GmbH
Address: Place de la Gare 2
1345 Le Lieu
SWITZERLAND
Web: www.eaton.com

4
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
Imminent dangers causing serious injuries. Danger of death.
Hazardous behaviors that could cause serious injuries.
Hazardous behaviors that could cause death.
Behaviors that could cause minor injuries to people or minor damages to things.
An electric shock can be fatal.
Avoid touching internal or external normally live parts whilst the system is powered on.
The unit contains energy storage components that can cause dangerous electrical discharges. After disconnecting the
unit from the power supply, allow at least 10 minutes for the components to cool down and discharge any remaining energy
before removing the guards and protective covers.
Read the instructions. These instructions are intended for Eaton certified installers.
The Eaton certified installer must be an expert in the field and must therefore be responsible for commissioning the system
according to the manufacturer’s instructions and local legislation.
Any repair or replacement of parts of the system must be performed exclusively by Eaton certified installers.
The notes preceded by this symbol relate to technical issues and ease of operations.
The EU Directive on Waste Electrical and Electronic Equipment (WEEE).
1.1 Field of applications
This installation manual is intended for end users. It describes how to securely install and commission the following Eaton
xStorage Home three phase (3P) hybrid inverters (Table 1):
1.2 Symbols used in this manual
This user manual is intended for end users. It describes how to securely use the following Eaton xStorage Home
3-phase (3P) hybrid inverters (Table 1):
Table 1 xStorage Home 3P system overview
Eaton xStorage Home 3P
Power Part Number Product Description
5 kVA XSTH3P050P075V01 XSTH Inverter 3Ph 5 kW PV 7.5
6 kVA XSTH3P060P090V01 XSTH Inverter 3Ph 6 kW PV 9
8 kVA XSTH3P080P120V01 XSTH Inverter 3Ph 8 kW PV 12
10 kVA XSTH3P100P150V01 XSTH Inverter 3Ph 10 kW PV 15

5
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
1.3 Conventions used in this document
This manual adopts the following type conventions and acronyms to refer to Eaton xStorage Home system or its parts:
• Screen type represents information that appears on the screen or LCD display (used to indicate screen content inside the text).
• ALL CAPITALS highlights critical points that require careful attention.
All abbreviations used in this document are listed in the Table 2.
Table 2 Glossary
Abbreviation Description
AC Alternating Current
BAT Battery
BMS Battery Management System
DC Direct Current
EMC Electromagnetic compatibility
EMI Electromagnetic interference
EPS Emergency Power Supply
FW Firmware
HV High Voltage
HW Hardware
IEC International Electrotechnical Commission
IP Internet Protocol
LAN Local Area Network
LCD Liquid Crystal Display
N Neutral
OV Over Voltage
PE Protective Earth
PPC Point of Common Coupling
PPE Personal Protective Equipment
PV Photovoltaic
RCD Residual Current Device
RCMU Residual Current Monitoring unit
SoC State of Charge
SW Software
UI User Interface
WEEE Waste Electrical and Electronic Equipment

6
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
2. Figures and specifications
Figure 1. Simplified xStorage Home 3P system installation
7 8 9
21 3
4
5 6
xStorage
Tag Description
1PV1 string
2PV2 string
3Battery
4Emergency power supply (EPS)
5Interlock system
6Privileged loads or critical loads
7Public grid
8Energy meter
9Home loads or non-critical loads

7
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
Tag Description
1Wi-Fi dongle
2Router
3Cloud
Figure 2. Network connection illustration
12
3
xStorage

8
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
Tag Description
1Rating plate location
2Rating plate example
Figure 3. Rating plates on xStorage Home 3P
xStorage
1
2

9
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
Eaton xStorage Home 3P
Part number XSTH3P050P075V01 XSTH3P060P090V01 XSTH3P080P120V01 XSTH3P100P150V01
PV inverter system for High Voltage
battery storage 5 kW 6 kW 8 kW 10 kW
DC Input
Maximum input power 7.5 kW 9 kW 12 kW 15 kW
Maximum input voltage 1000 V
Minimum input voltage 200 V
Nominal input voltage 720 V
PV MPPT voltage range 150 V - 950 V
DC voltage range - independent MPPTs
at maximum DC power 385 V - 850 V at 5 kW 500 V-850 V at
6.5 kW 655 V – 850 V at 8.5 kW 770 V - 850 V at
10 kW
DC voltage range - MPPT connected in
parallel at maximum DC power 290 V – 850 V 350 V – 850 V 460 V – 850 V 425 V – 850 V
Maximum power x MPPT 5 kW 6.5 kW 8.5 kW 10 kW
Maximum MPPT power - Maximum
imbalance
5 kW at MPPT1 +
2.5 kW at MPPT2
6.5 kW at MPPT1 + 2.5 kW at
MPPT2
8.5 kW at MPPT1 + 3.5 kW at
MPPT2
10 kW at MPPT1 +
5 kW at MPPT2
Maximum input current x MPPT 13 A
Short-circuit current x MPPT 15 A
Number of MPPTs 2
Maximum number of strings x MPPT 1+1
Maximum backfeed current to PV array 0 A
Battery charger
Battery type Lithium
Battery voltage range 170 V - 500 V
Max charging/discharging current 25 A
Nominal battery voltage 200 V 240 V 320 V 400 V
Max charging/discharging power 5 kW 6 kW 8 kW 10 kW
Communication interfaces CAN/RS485
AC output
Main connection 3W+N+PE
Nominal power 5 kVA 6 kVA 8 kVA 10 kVA
Maximum active power 5 kW 6 kW 8 kW 10 kW
AC voltage range 400 Vac ± 15% (*)
Output nominal current 7.2 A 8.7 A 11.5 A 14.5 A
Main nominal frequency 50 Hz
Frequency range 47 Hz – 53 Hz (*)
Cos ϕ1 (adj ± 0.80)
THD < 3%
Max output overcurrent protection 25 A
Max output fault current 25 A
EPS output
Maximum power 5 kVA 6 kVA 8 kVA 10 kVA
AC voltage range 400 Vac ± 15 % (*)
Output nominal current 7.2 A 8.7 A 11.5 A 14.5 A
Main nominal frequency 47 Hz - 53 Hz (*)
Intervention time < 5 sec (*)
THD < 3%
Max output overcurrent protection 25 A
Max output fault current 25 A
Efficiency
Maximum efficiency 97.6 %
Weighted efficiency (Euro) 97 %
Battery typical efficiency 96 %
Protective devices
DC polarity reversal As standard
Table 3 xStorage Home 3P technical specifications

10
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
Eaton xStorage Home 3P
Part number XSTH3P050P075V01 XSTH3P060P090V01 XSTH3P080P120V01 XSTH3P100P150V01
Battery polarity reversal As standard
Battery overload protection As standard
AC short-circuit protection As standard
Isolation monitoring unit As standard
Interface protection and anti-islanding In compliance with local legislation
RCMU (Residual Current Monitoring
Unit) As standard
DC Overvoltage protective device
(MOV + Surge protector) As standard
AC Overvoltage protective device
(MOV + surge protector) As standard
Battery Overvoltage protection
(MOV + SURGE PROTECTOR ) As standard
Accessories supplied
DC connectors Quick connectors
AC connectors Spring contacts terminal strip, M25 cable gland
Battery connection Quick connectors
DC switch As standard
Battery automatic switch Built-in
User interface Graphic Touch Screen 4.3’’ color LCD
Communication interfaces USB/CAN Bus/RS485/Ethernet/WiFi
External alarm signal As standard
Datalogger Built-in
Warranty 5 years
Environmental conditions
Ambient temperature From -20° C to + 60° C
Power derating temperature range From 40° C to + 60° C
Storage temperature From -30° C to + 70° C
Relative humidity From 5 % to 95 % without condensation
Noise level < 50 dB(A) at 1 m
Maximum operating altitude
without derating 2000 m
Pollution degree classification PD 3
Installation environmental category Indoor, unconditioned
Physical description
Protection rating IP 21
Overvoltage category (IEC 62109-1) II (DC, Battery inputs) III (AC output)
Cooling concept I-cool, forced cooling
Dimensions (W x H x D in mm) 476 x 735 x 170
Weight 25 kg
Fitting system Wall bracket
Safety
Protection class I
DC to AC isolation Transformerless
Battery to AC and DC isolation Transformerless
Certifications CE
EMC and Safety standards EN62109-1; EN62109-2; EN61000-6-2; EN61000-6-3; EN61000-3-2; EN61000-3-3; EN61000-3-11; EN61000-3-12
Grid codes CEI 0-21; VDE AR-N 4105; VDE 0126-1-1 VFR 2019; EN 50549-1
Other Features
BACKUP/OFF-GRID mode operation Yes, with external interlock
ON-GRID/BACKUP/OFF-GRID
selection mode Yes, automatic
Grid support (grid services) Yes, if required by the applied grid code
Residential load management Yes, with Printed Circuit Board (PCB) 1 dry contact 4 A 250 Vac
(*) The specified range may vary according to the connection standards in place in the country of installation.

11
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
3. Cautions
These instructions are intended for end users.
Before carrying out any operations, make sure to have read and understood this manual. Do not make changes and
do not carry out maintenance operations not described in this manual. The manufacturer does not accept
responsibility for injuries to people and damages to things occurred because the information within this manual has
not been read and followed.
Check the regulations applied by the electricity provider. Check the solar panels manufacturer’s instructions.
Check the batteries manufacturer’s instructions.
The installation must only be carried out only by Eaton certified personnel.
Only high voltage (HV) lithium-ion batteries approved by Eaton can be connected to the xStorage Home 3P system.
The use of non-approved batteries can affect the correct functioning of the system and relieves Eaton from all liabilities
and invalidates the guarantee.
It is strictly prohibited to open the xStorage Home 3P system except as listed in this manual. The installation of
the equipment must not be carried out by personnel who are not certified by Eaton.
For any doubts or problems regarding the use of the system, even if not described here, please contact the Eaton
certified installer or Eaton sales representative.
The xStorage Home 3P system must not be subjected to any type of modification. Eaton declines any responsibility
if the rules for correct installation are not respected and is not responsible for the system upstream or downstream
of the equipment it supplies.
The exclusion of protective devices is extremely dangerous and relieves the manufacturer of any responsibility
for damage to people and things.
3.1 Operating environment and restrictions
Each system must be used exclusively for the operations it was designed for and within the operative ranges specified in
the nameplate and / or in the relative technical datasheet, according to the national and international safety standards.
Any use different from the intended use specified by the manufacturer is to be considered totally inappropriate and dangerous
and in this case the manufacturer declines all responsibility.
This equipment is an integrated system capable of converting a direct current (DC), coming from a photovoltaic generator and
a battery, into an alternating current (AC) suitable for use by local loads and / or fed into the public grid.
Operating range limits:
The xStorage Home 3P system can only be used with photovoltaic modules that do not require the earthing of one of the poles.
xStorage Home 3P can only be used with photovoltaic modules that meet the specific requirements of class A in accordance
with the indications of the IEC 61730 standard.
Do not connect any other energy source to the inverters in addition to the modules described above. The leakage current during
normal operation must not exceed the limits specified in the technical characteristics.
A high voltage lithium-ion battery (HV) can be connected to the xStorage Home 3P system at the BAT input, which acts as
a storage element for the excess energy produced by the photovoltaic generator. The stored energy is then released to the
system which will make it available, at the time and in the most appropriate way, to local loads in order to fully or drastically
reduce the drawn of energy from the distribution network.
The xStorage Home 3P system can be connected to the distribution network only in the countries which the system
is certified for.
The xStorage Home 3P system can be used only respecting all the technical characteristics.

12
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
3.2 Protection from electric shock
3.3 Warning decals and rating plate
An electric shock can be fatal.
Avoid touching internal or external normally live parts whilst the system is powered on.
Cables and connections must always be secured, in good conditions, insulated and suitably sized.
The labels on the equipment must NOT be removed, damaged, soiled or hidden.
The labels must always be visible and in good conditions.
The technical data shown in this manual do not however replace those shown on the data plates on the equipment.
The equipment contains capacitors that store static electricity, which could produce dangerous electric discharges.
Make sure that the devices have discharged their energy before carrying out any work on the equipment.
Improper or unauthorized use:
Although carefully constructed, all electrical appliances can catch fire.
The xStorage Home 3P system is intended for indoor installation.
Optimal operation of the xStorage Home 3P system is ensured at a maximum ambient temperature of 40 °C (104 °F).
The xStorage Home 3P system must be transported and stored in indoor locations with a temperature range of
-30 °C to +70 °C (-22 °F and 158 °F).
The xStorage Home 3P system must be used in locations with no acids, gases or other corrosive substances.
The xStorage Home 3P system must be used and stored in locations with relative humidity ranging from
5% to 95% without condensation.
The xStorage Home 3P system must be transported in locations with relative humidity ranging from 5 % to 95 %.
The xStorage Home 3P system must be used and stored in locations with atmospheric pressure ranging from
86 kPa to 106 kPa.
The xStorage Home 3P system must be transported in locations with atmospheric pressure ranging from 70 kPa to
106 kPa.
The xStorage Home 3P system must be used at a maximum altitude above sea level of 3000 m (9750 feet). For
altitudes above 2000 m, due to the rarefaction of the air, specific conditions may occur which must be considered when
choosing the place of installation. All installations at altitudes above 2000 m must be assessed case by case considering
the following critical issues:
• Less efficient cooling.
• Decrease in the dielectric strength of the air and, in the presence of high voltages, the creation of electric arcs.
• Presence of cosmic radiation that can affect the correct functioning of the electronic components.

13
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
4. General description
4.1 xStorage Home 3P high voltage hybrid inverter
The xStorage Home 3P High Voltage (HV) hybrid inverter (see Figure 1) is a DC - AC solar inverter, designed for use in indoor
environments. It has been designed to be used in combination with PV panels and connected to the electricity grid and a high
voltage (HV) storage battery to optimize self-consumption. In the event of a temporary or permanent power outage, the xStorage
Home 3P automatically enables the off-grid operation on the EPS port supplying, with the backup energy, the part of the home
system connected to it.
All adjustment and control operations can be performed on the LCD (touch screen) located on the front of the xStorage Home 3P.
4.2 Operating modes
The xStorage Home 3P HV hybrid inverter can operate in different operating modes in order to meet the specific needs of
the user. Please consider that only the Eaton certified installer can change the operating modes depending from user needs.
4.2.1 “SELF-CONSUMPTION” mode
In the presence of sunshine, the energy from the photovoltaic field is used primarily to supply the domestic loads and secondly to
charge the battery. Further energy in excess is transferred to the grid. If the energy required by the loads is high and the available
energy from photovoltaic field and battery is not enough, the remaining part is taken from the grid.
This operating mode is mainly indicated in installations with a low tariff for the energy fed into the grid and a high cost
for the energy purchased from the utility.
Figure 4. Eaton xStorage Home 3P self-consumption mode during the day
xStorage
In the absence of energy from the photovoltaic system, the battery is discharged to supply domestic loads. If the energy required
by the loads is higher than the energy stored the battery, the remaining part is taken from the grid. The energy stored in the battery
usually does not feed in to the grid and it is used to supply the home loads.
Figure 5. Eaton xStorage Home 3P self-consumption mode during the night
xStorage

14
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
4.2.2 “FEED-IN CONTROL” mode
This operating mode is mainly indicated in installations where local regulations require a limitation on the energy that
is injected in to the grid.
1
xStorage
Figure 6. Eaton xStorage Home 3P feed in control mode during the day
In the presence of sunshine, the energy from the photovoltaic system is used primarily to supply the domestic loads and
secondly to charge the battery. Further energy in excess is transferred to the grid with the possibility to set a limit on the value
of the maximum power fed into the grid. If the set limit is zero and there is no demand for energy from the loads, the inverter
will limit the input power to the set value by reducing the production of the photovoltaic energy until it completely inhibits it.
Therefore, by setting the input limit to 0 W, the system will totally prevent the transfer of energy to the grid. Moreover, if the
energy required by the loads is high and the available energy from photovoltaic field and battery is not enough, the remaining part
is taken from the grid.
1. Pmax
Figure 7. Eaton xStorage Home 3P feed in control mode during the night
xStorage
In the absence of energy from the photovoltaic field, the battery is discharged to supply domestic loads. If the energy required
by the loads is high and the energy in the battery is not enough, the remaining part is taken from the grid. The energy stored in
the battery usually does not feed in to the grid and it is used to supply the home loads.

15
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
Figure 8. Eaton xStorage Home 3P battery manager mode during the day
xStorage
In the presence of sunshine, the energy from the photovoltaic system is used primarily to supply the domestic loads and
secondly to charge the battery starting from the set charge start time. This allows you to start charging the battery at the most
convenient time of the day.
4.2.3 “BATTERY MANAGER” mode
This operating mode is mainly indicated in installations where it is convenient to enable the battery charge during the
high photovoltaic production time over the day and to operate a delayed discharge of the battery when the home energy
demand is high or when the cost of energy is expensive.
Figure 9. Eaton xStorage Home 3P battery manager mode during the night
xStorage
In the absence of energy from the photovoltaic field, the battery is discharged to supply the domestic loads only starting from the
set time in order to keep the energy reserve ready for the evening moments of maximum demand and minimize any consumption
from the grid in case of absorption peaks. It is also possible to set a usage time limit to disable the battery use and keep an
energy reserve for the morning after to support the energy demand from the loads when the photovoltaic production is not
present yet.

16
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
Figure 10. Eaton xStorage Home 3P Emergency power supply (EPS) mode
xStorage
In case of a power outage, the energy from the photovoltaic system is used primarily to supply domestic loads and secondly to
charge the battery. If the photovoltaic system is not able to supply the loads then the remaining part is taken from the battery. In
the absence of photovoltaic production, the energy required to supply the house loads will be totally taken from the battery.
4.2.4 “EMERGENCY POWER SUPPLY (EPS)” mode
In case of a power outage, this operating mode allows an emergency output (EPS) to be activated to supply the
privileged domestic loads. In order to activate this operating mode, the presence of the battery is required.
WARNING:
In order to preserve the health of the battery, the automatic enabling of the EPS port occurs only if the state of
charge is higher or equal to 5 %. Below this value the EPS mode is inhibited.
WARNING:
The “EPS” mode automatically ends during the discharge in case the battery status reaches the minimum value of 0
%. The mode is automatically restored if the solar energy from the panels manages to bring the battery to a state of
charge equal or higher than 5 %.
WARNING:
The total power of the loads connected to the EPS output must be within the range specified in the technical
data. If the total load is higher, the xStorage Home 3P will enter in protection mode, disabling the output power and
signaling the overload event. After a few seconds it will attempt to restore the regular operation of the EPS port. This
restart mode will continue until the total load connected to the EPS port is compatible with the maximum ratings
specified in the technical data. It is therefore recommended to connect only critical loads to the EPS port.
WARNING:
In EPS mode, some loads may not work properly even if their total rated power is within the limits specified
in the technical data. This can happen because the inrush currents could be too high (refrigerators, air conditioners,
hydraulic pumps, etc.). In these cases, the xStorage Home 3P hybrid inverter will enter in protection mode, disabling
the output power and the overload event will be flagged. After a few seconds it will attempt to restore the regular
operation of the EPS port. This restart mode will continue until the total load connected to the EPS port is compatible
with the maximum ratings specified in the technical datasheet. It is therefore recommended to connect only critical
loads to the EPS port.
WARNING:
The activation of the EPS port in case of a power outage can take a predetermined time which depends on the
regulations in force in the country of installation. For this reason, the xStorage Home 3P system cannot be
used as a UPS as it does not guarantee the continuity of power supply of the loads connected to it.

17
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
This operating mode allows you to maintain a reserve of energy stored in the battery always ready to be used in the
event of a power outage and is particularly suitable for installations in areas where power outages often occur.
4.2.5 “BACKUP RESERVE” mode
Figure 11. Eaton xStorage Home 3P back up reserve mode
xStorage
In this operating mode the battery is forced to be charged up to a pre-set minimum level and usually does not discharged below
that level during normal self-consumption operation. The reserve of the battery state of charge is maintained by the energy
produced by the photovoltaic field or it might be taken from the grid. In order to guarantee the pre-established backup level, the
energy stored in the battery is usually not fed in to the grid, but it is reserved exclusively to supply the loads.
4.3 HV Lithium-ion battery
The xStorage Home 3P HV hybrid inverter can be connected to a high voltage lithium-ion storage battery (HV) to store the energy
from the PV panels and to optimize self-consumption.
The xStorage Home 3P hybrid inverter can operate with various high voltage (HV) batteries which have been specifically tested
and approved by Eaton to ensure the safety and optimal operation of the system.
WARNING:
Connect only the battery models approved by Eaton to the xStorage Home 3P hybrid inverter. Contact your Eaton
sales representative to get further details.
The calibration charge is primarily carried out by the energy coming from the solar panels which is entirely destined for
this purpose. If the energy available from the solar panels is not enough then the remaining part is taken from the grid.
Based on the state of health of the battery and to get an accurate and reliable state of charge (SoC) indication, the control module
integrated in the battery (BMS) cyclically requests the xStorage Home 3P hybrid inverter to carry out a calibration and to charge up to
100 %. This allows to make the best use of the battery, maximize the useful life of the internal cells and to optimize battery performances.
4.3.1 Calibration charge
WARNING:
During the calibration charge, normal system functionalities are disabled, and the battery cannot be used by the system.
All system functionalities are
automatically restored at the end of the calibration process.

18
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
WARNING:
The maintenance charge is a safety function of the battery to avoid damages. For this reason, the xStorage Home 3P hybrid inverter
can activate grid charging if the available photovoltaic energy is not enough.
WARNING:
During the maintenance charge, normal system functionalities are disabled, and the battery cannot be used by the system.
All system functionalities are automatically restored at the end of the maintenance process.
WARNING:
During the maintenance charge the EPS mode is disabled. It is automatically restored at the end of the maintenance process.
WARNING:
Maintenance charge is required by the battery integrated control module (BMS). The xStorage Home 3P hybrid inverter cannot in
any case disable the command from the battery.
The maintenance charge brings the state of charge from the minimum value to a value determined by the BMS based
on the state of health of the cells. The charging current is also determined by the BMS module based on the health and
temperature of the battery itself.
The duration of the maintenance charge depends on the energy available from the solar panels and on the health of the cells of
the battery. This process can take a long time (hours) especially during the winter when the available solar energy can be very low.
During the winter period or after long periods of inactivity, the battery may remain at the minimum state of charge for a long time
with the risk of a deep discharge phenomena with consequent risk of structural damage to the internal cells. Therefore, to avoid
damages of the battery, the control module integrated in the battery (BMS) may require the xStorage Home 3P hybrid inverter to
carry out a maintenance charge.
4.3.2 Maintenance charge
Metallic or excessively sharp materials must not be used.
The display backlighting is turned off when the display is not used by the user. The LCD display remains operational even
if it appears to be off. To reactivate it, simply touch the display surface.
The maintenance charge status is shown on the display status bar.
The control panel fitted on the xStorage Home 3P is a graphic touchscreen display. To input commands, simply touch the surface of
the display with a finger or with objects suitable for the purpose.
4.4 Touch-screen control panel
WARNING:
During the calibration charge the EPS mode is disabled. It is automatically restored at the end of the calibration process.
WARNING:
Calibration charge is required by the battery integrated control module (BMS). The xStorage Home 3P hybrid inverter cannot in any
case disable the command from the battery.
The duration of the calibration charge depends on the energy available from the solar panels and on the health of the cells of the battery.
This process can take a long time (hours and / or days) especially during the winter when the available solar energy can be very low.
The calibration charge status is shown on the display status bar.

19
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
See the connection instructions shown in
Figure 2.
Insert the Wi-Fi dongle supplied with the inverter accessories in the USB port and wait for the system to recognize
the device (transparent Wi-Fi icon).
To set the correct operation of the connection it is necessary to access the configuration menu “SETTINGS” and set
the networking parameters of the “WLAN” menu according to the characteristics of the local network to be accessed.
Please refer to the xStorage Home 3P user interface display manual, “NETWORKING” section.
To ensure optimal Wi-Fi connectivity, make sure that the Wi-Fi signal available near the installation of the xStorage Home
3P system is high enough to allow a stable connection. For this purpose, during the configuration of the network parameters,
the scanning and selection of the Wi-Fi network carried out by the xStorage Home 3P reports the signal strength of the wireless
network to which you intend to connect: select a network with signal strength S > - 60 dBm. If the detected signal is weak
(S < -60 dBm), the connection is not guaranteed and therefore it is necessary to provide for the use a Wi-Fi repeater.
If the configuration operations are carried out correctly, the effective connection to the local Wi-Fi network is shown by the
Wi-Fi icon (icon highlighted) on the status bar of the display and by the stable lighting of the blue LED on the control panel.
WARNING:
Use only the Wi-Fi dongle supplied with the inverter accessory. The correct functioning of Wi-Fi connectivity is not
guaranteed with not approved similar devices.
5. Electrical connections
5.1 Wi-Fi connection
5.4 System switching off
5.2 LAN connection
By using a Wi-Fi dongle, the xStorage Home 3P inverter can access a local Wi-Fi network allowing to activate the remote
connection and system monitoring functions.
Proceed as follows to switch off the system:
If the checks listed above were successful, proceed as follows:
If the Wi-Fi connection is weak and / or not very stable, alternatively the xStorage Home 3P inverter can access a wired
local network via the LAN port allowing to activate the remote connection functions and system monitoring.
Please contact Eaton certified installers to setup LAN connection.
5.3 System switching on
Before starting the system, carry out the following checks:
1. Check that the inverter is correctly fixed to the wall.
2. Check that the PV string connections have been made correctly.
3. Check that the AC GRID and EPS (if present) connections have been made correctly.
4. Check that the BATTERY connections have been made correctly.
5. Check that the EARTH connection (MANDATORY) has been made correctly.
6. Verify that the ENERGY METER connections have been made correctly.
7. Verify that SMART LOAD connections (if present) have been made correctly.
8. Check that the connection cover is closed and secured with the fixing screws.
1. Enable the inverter stand-by by turning the ON/OFF switch in the “0” position.
2. Turn off the DC switch (position 0).
3. Turn off the AC GRID and EPS (if present) circuit breakers.
4. Turn off the BATTERY circuit breaker (if present) and turn off the HV battery.
5. Wait for the display to turn off.
6. Do not carry out other operations on the inverter for at least 10 minutes. The inverter contains capacitors
that need a minimum time to discharge.
1. Turn on the DC disconnector switch (position 1).
2. Turn on the external main AC line switch.
3. Turn on the AC GRID and EPS (if present) circuit breakers.
4. Turn on the BATTERY circuit breaker (if present) and turn on the HV battery.
5. Wait for the display to turn on.
6. Start the inverter by turning the ON/OFF switch in position 1.

20
XSTORAGE HOME 3P ENERGY STORAGE SYSTEM USER MANUAL MN700011EN May 2023 www.eaton.com
1. Power Supply
• LED on: the xStorage Home 3P is powered and is operating.
• LED blinking: the xStorage Home 3P is in the start-up and self-test phase.
• LED off: the xStorage Home 3P is not powered.
2. General alarm
• LED on: the xStorage Home 3P has detected a fault. The LCD display activates the corresponding alarm
icon and shows the information related to the alarm occurred on the status bar (See the “Troubleshooting”
section in the xStorage Home 3P installation manual).
• LED off: the xStorage Home 3P has not detected any fault.
3. Communication
• LED on: communication with external devices is enabled.
• LED off: communication with external devices is disabled.
4. USB port
• USB port available for data download, system update, Wi-Fi dongle connection.
5. Graphic touch-screen display
• Graphic touch screen display which displays the system status and user / installer settings.
6.1 General Information
Figure 12. xStorage Home 3P display
Do not connect portable hard disks, MP3 players, computers and any other device other than a USB
memory stick or Wi-Fi dongle to the USB port. The system is compatible with most of the USB memory
sticks on the market. However, the system may not recognize some types of USB memory sticks. In this
case it is recommended to try again replacing it with another model.
See the connection instructions shown in the xStorage Home 3P installation manual.
6. Control panel
Tag Description
1Power supply LED
2General alarm LED
3Communication LED
4USB port
5Graphic touch-screen display
Other manuals for xStorage Home 3P
3
Table of contents
Other Eaton Storage manuals

Eaton
Eaton C-632X User manual

Eaton
Eaton Cutler Hammer SRAM PC104 User manual

Eaton
Eaton xStorage Home 3P User manual

Eaton
Eaton xStorage Compact User manual

Eaton
Eaton xStorage Home 3P User manual

Eaton
Eaton xStorage Compact 20 kW User manual

Eaton
Eaton xStorage Home 3P User manual

Eaton
Eaton Cutler-Hammer SRAM PC104 User manual

Eaton
Eaton xStorage 400 User manual

Eaton
Eaton RE Series User manual