NOTES
TABULAR DATA
1. Measurement/DataProcessingSystems: Primary-FChart: proprietaryEAWsoftware;Secondary- Brüel& Kjær2012.
2. MicrophoneSystems: EarthworksM30; Brüel&Kjær4133
3. Measurements: DualchannelFFT;length:32 768 samples;samplerate:48 kHz; logarithmicsinewavesweep.
4.Measurement System Qualification(includesalluncertainties):SPL:accuracy+/-0.2 dB@1kHz,precision +/-0.5 dB20Hzto 20 kHz,resolution0.05dB;Frequency: accuracy+/-1%,
precision+/-0.1Hz,resolution the largerof1.5Hzor1/48octave;Time:accuracy+/-10.4 µs,precision+/-0.5µs,resolution10.4µs;Angular:accuracy+/-1°,precision+/-0.5°,resolution0.5°.
5. Environment: Measurementstime-widowedandprocessed toeliminateroomeffects,approximatingananechoic environment. Dataprocessed asanechoicorfractionalspace,as noted.
6. MeasurementDistance: 7.46m.Acousticresponsesrepresentcomplexsummationofthesubsystems at20m. SPLisreferencedtootherdistancesusingtheInverseSquareLaw.
7. Volts: Measuredrmsvalue ofthetestsignal.
8. Watts: Per audioindustrypractice,“loudspeaker watts” are calculatedasvoltagesquareddividedby ratednominalimpedance. Thus,these are notTrueWattunitsofenergyasdefined by
InternationalStandard.
9. SPL: (SoundPressureLevel) Equivalenttotheaveragelevel ofasignalreferencedto 0 dBSPL= 20microPascals.
10.Subsystem: Thisliststhe transducer(s)andtheiracousticloading foreachpassband.Sub=Subwoofer,LF=LowFrequency,MF= MidFrequency,HF =HighFrequency.
11.Operating Mode: Userselectableconfigurations.Betweensystemelements,acomma(,)=separateamplifierchannels;aslash (/) = singleamplifier channel. DSP=DigitalSignalProcessor.
IMPORTANT:To achievethespecifiedperformance, the listedexternalsignalprocessingmust beusedwithEAW-providedsettings.
12.Operating Range: Range wheretheprocessedFrequencyResponse stayswithin-10 dBSPLof the poweraveragedSPLwithinthisrange;measured on thegeometricaxis.Narrow band
dipsareexcepted.
13.Nominal Beamwidth: Designanglefor the-6dBSPLpoints,referencedto0 dB SPLasthe highest level.
14.AxialSensitivity: PoweraveragedSPLovertheOperating Rangewithaninputvoltagethat would produce1Wat the nominalimpedance;measuredwith no externalprocessingonthe
geometricaxis,referenced to1m.
15.Nominal Impedance: Selected 4,8,or16ohm resistancesuchthat theminimumimpedancepointis nomorethan20%below this resistanceover theOperatingRange.
16.AcceleratedLifeTest: Maximum testinputvoltageappliedwithan EIA-426Bdefinedspectrum;measuredwith recommendedsignalprocessingandRecommended ProtectionFilter.
17.CalculatedAxialOutput Limit: Highest average andpeakSPLspossibleduring theAcceleratedLifeTest. ThePeakSPLrepresentsthe2:1(6 dB)crestfactorofthe LifeTestsignal.
18.High Pass Filter: Thishelpsprotecttheloudspeakerfrom excessiveinputsignallevelsat frequencies belowtheOperatingRange.
GRAPHICDATA
1.Resolution:Toremoveinsignificant finedetails,1/12octavecepstralsmoothingwasapplied toacousticfrequencyresponsesand 1/3 octave cepstral smoothing wasappliedtothe
beamwidthandimpedancedata. Othergraphs areplottedusingrawdata.
2.Frequency Responses: Variationinacousticoutputlevelwithfrequencyforaconstantinputsignal.Processed:normalizedto 0 dB SPL. Unprocessedinputs:2V(4 ohm nominal impedance),
2.83V(8 ohmnominalimpedance),or4 V(16 ohmnominalimpedance)referenced to adistanceof1m.
3.Processor Response: The variationinoutputlevelwith frequency foraconstantinputsignal of 0.775V=0dB reference.
4.Beamwidth:Averageanglefor each 1/3octavefrequencybandwhere,startingfrom therearoftheloudspeaker,theoutputfirstreaches -6dBSPLreferenced to0dBSPLasthehighest
level.Thismethodmeans theoutputmaydropbelow -6 dBSPLwithin thebeamwidthangle.
5.Impedance: Variationin impedance magnitude,inohms,withfrequency withoutregardtovoltage/currentphase.Thismeans the impedancevaluesmaynot
beusedto calculateTrueWatts(see9 above).
6.Polar Data:Horizontalandvertical polarresponsesforeach1/3 octavefrequencyband 100Hzto16kHz orOperatingRange.