NOTES
TABULAR DATA
1. Measurement/DataProcessingSystems: Primary-FChart: proprietaryEAWsoftware;Secondary- Brüel& Kjær2012.
2. MicrophoneSystems: EarthworksM30; Brüel&Kjær4133
3. Measurements: DualchannelFFT;length:32 768 samples;samplerate:48 kHz; logarithmicsinewavesweep.
4.Measurement System Qualification(includesalluncertainties):SPL:accuracy+/-0.2 dB@1kHz,precision +/-0.5dB20Hzto 20kHz,resolution0.05dB; Frequency:accuracy+/-1%,
precision+/-0.1Hz,resolution the largerof1.5Hzor1/48octave;Time:accuracy+/-10.4µs,precision+/-0.5µs,resolution 10.4µs;Angular:accuracy+/-1°,precision +/-0.5°, resolution0.5°.
5. Environment: Measurementstime-widowedandprocessed toeliminateroomeffects,approximatingananechoic environment.Dataprocessedasanechoicor fractionalspace,asnoted.
6. MeasurementDistance: 7.46m.Acousticresponsesrepresentcomplexsummationofthesubsystems at 20 m. SPLisreferencedtootherdistancesusingtheInverseSquareLaw.
7. Volts: Measuredrmsvalue ofthetestsignal.
8. Watts: Per audioindustrypractice,“loudspeaker watts” are calculatedasvoltagesquareddivided by ratednominalimpedance. Thus,these arenotTrueWattunitsofenergyasdefined by
InternationalStandard.
9. SPL: (SoundPressureLevel) Equivalenttotheaveragelevel ofasignalreferencedto 0dBSPL=20microPascals.
10.Subsystem: Thisliststhe transducer(s)andtheiracousticloading foreachpassband.Sub=Subwoofer,LF=LowFrequency,MF = MidFrequency, HF =HighFrequency.
11.Operating Mode: Userselectableconfigurations.Betweensystemelements,acomma(,)=separateamplifierchannels;aslash (/) = singleamplifierchannel.DSP=DigitalSignalProcessor.
IMPORTANT:Toachievethe specified performance,thelistedexternal signal processingmustbeusedwith EAW-provided settings.
12.Operating Range: Range wheretheprocessedFrequencyResponse stayswithin -10 dBSPLof thepoweraveragedSPLwithinthisrange; measuredonthegeometricaxis. Narrowband
dipsareexcepted.
13.Nominal Beamwidth: Designanglefor the-6dBSPLpoints,referencedto0 dB SPLas the highestlevel.
14.AxialSensitivity: PoweraveragedSPLovertheOperating Rangewithaninputvoltagethat wouldproduce1Wat thenominalimpedance;measuredwith noexternalprocessingonthe
geometricaxis,referenced to1m.
15.Nominal Impedance: Selected 4,8,or16ohm resistancesuch that theminimumimpedancepoint is nomorethan20% below thisresistanceovertheOperating Range.
16.High Pass Filter: Thishelpsprotecttheloudspeakerfrom excessiveinputsignallevelsat frequenciesbelowtheOperatingRange.
17.AcceleratedLifeTest: System: Maximumtestinputvoltageapplied with anEIA-426Bdefinedspectrum; measured withspecifiedsignalprocessing;Transducer:AES2-1984R 1997.
18.CalculatedAxialOutput Limit: Highest average andpeakSPLspossible during theAcceleratedLifeTest. ThePeak SPLrepresentsthe2:1 (6dB)crestfactorof theLifeTestsignal.
GRAPHICDATA
1.Resolution:Toremoveinsignificant finedetails,1/12octavecepstralsmoothingwasapplied toacousticfrequencyresponsesand 1/3octavecepstralsmoothingwasapplied to the
beamwidthandimpedancedata. Othergraphs areplottedusingrawdata.
2.Frequency Responses: Variationinacousticoutputlevelwithfrequencyforaconstantinputsignal.Processed:normalizedto 0 dB SPL.Unprocessedinputs:2 V (4ohmnominalimpedance),
2.83V(8 ohmnominalimpedance),or4 V(16ohmnominalimpedance) referencedtoadistanceof1 m.
3.Processor Response: The variationinoutputlevelwith frequencyforaconstantinputsignal of0.775V=0 dB reference.
4.Impedance: Variationin impedance magnitude,inohms,with frequency withoutregardtovoltage/currentphase.Thismeans theimpedancevaluesmay not
beusedto calculateTrueWatts(see 8above).