EAW VFS220i User manual

DOUBLE 12INCH SUBWOOFER
See NOTES TABULAR DATA for details
CONFIGURATION
Subsystem:
Transducer Loading
SUB 2x 12 in cone Vented
Operating Mode:
Amplifier Channels External Signal Processing
Single-amp LF/LF DSP w/1-way filter
PERFORMANCE
Operating Range: 33 Hz to 154 Hz
Nominal Beamwidth:
Horz 360°
Vert 360°
Axial Sensitivity (SPL):
LF1/LF2 (whole space) 96 dB 33 Hz to 154 Hz
(half space) 102 dB 33 Hz to 154 Hz
Input Impedance (ohms):
Nominal Minimum
LF1/LF2 4 4.2 @ 143 Hz
High Pass Filter: High Pass=>35 Hz, 24 dB/octave Butterworth
Accelerated Life Test:
System
LF1/LF2 63.2 V 1000 W @ 4 ohm
Calculated Axial Output Limit:
Average Peak
LF1/LF2 (whole space) 126 dB 132 dB
(half space) 132 dB 138 dB
ORDERING DATA
Description Part Number
EAW VFS220i Dual 12-inch Subwoofer Black 2041018-90
EAW VFS220i Dual 12-inch Subwoofer White 2041033-90
Optional Accessories
EAW Eyebolt/Forged Shoulder (M10) 0031810
EAW SBK-MK23_VFS-VFR129 Flybar Black [FB2VSK] 2038319
EAW ACC CASTER KIT 100 [ACC-CK100] 0032377-90
VFS220i Specifications
Eastern Acoustic Works • One Main Street • Whitinsville, MA 01588 • tel 800 992 5013 / 508 234 6158 • fax 508 234 8251 • www.eaw.com
August 2013Part Number: RD0752 Rev 100EAW products are continually improved. All specications are therefore subject to change without notice.
FEATURES
• High output sub bass system
• Dual 12-in cone transducers
• Optimally vented for increased response
• Extended pole mount cup creates stable base
• Easy lift handles (Black version only)
DESCRIPTION
The VFS “i” revision brings the VF concept more fully into the EAW product
line. VFS “i” Series black versions use handles from the KF and JF Series. An
installation only white version comes without handles or a pole mount cup.
The VFS220i sub bass system includes dual, direct radiating 12-in LF cone
transducers mounted in an optimally vented enclosure. Enclosure venting
uses the enclosure’s resonance to enhance LF response while limiting driver
wear.
The VFS220i black version includes traditional portable features such as a
pole-mount cup, parallel NL4 4-terminal connectors, barrier strip inputs and
handles that accept accessory covers for permanent installation. The white,
installation-only versions omit handles and the pole-mount cup but in-
clude NL4 connector, barrier strip inputs and multiple mounting points. The
new design leaves the enclosure sides completely smooth and attractive.
Optional rigging hardware is available for precongured arrays of VFR and
VFS systems.
Six year warranty.

NOTE: This drawing has been reduced. Do not scale.
VFS220i Specifications
Eastern Acoustic Works • One Main Street • Whitinsville, MA 01588 • tel 800 992 5013 / 508 234 6158 • fax 508 234 8251 • www.eaw.com
August 2013Part Number: RD0752 Rev 100EAW products are continually improved. All specications are therefore subject to change without notice.
Hardwood plywood
Wear resistant textured black paint
Powder-coated perforated steel
Material
Finish
Grille
ENCLOSURE
VFS220i BLACK
PENDING

NOTE: This drawing has been reduced. Do not scale.
VFS220i Specifications
Eastern Acoustic Works • One Main Street • Whitinsville, MA 01588 • tel 800 992 5013 / 508 234 6158 • fax 508 234 8251 • www.eaw.com
August 2013Part Number: RD0752 Rev 100EAW products are continually improved. All specications are therefore subject to change without notice.
Hardwood plywood
Wear resistant textured white paint
Powder-coated perforated steel
Material
Finish
Grille
ENCLOSURE
VFS220i WHITE
PENDING

PERFORMANCE DATA
See NOTES GRAPHIC DATA for details
Frequency Response: Processed
Complete = green
Frequency Response: Unprocessed
Complete = green
SPL (dB)
SPL (dB)
Frequency (Hz) Frequency (Hz)
Impedance
Complete = green
Processer Response
Complete = green
Ohms
Degrees
Frequency (Hz) Frequency (Hz)
100
10
1
10 100 1000 20000
VFS220i Specifications
Eastern Acoustic Works • One Main Street • Whitinsville, MA 01588 • tel 800 992 5013 / 508 234 6158 • fax 508 234 8251 • www.eaw.com
August 2013Part Number: RD0752 Rev 100EAW products are continually improved. All specications are therefore subject to change without notice.
10 100 1000 20000
100
60
70
80
90
120
110
10 100 1000 20000
-10
-50
-40
-30
-20
10
0
10 100 1000 20000
0
-40
-30
-20
-10
20
10

NOTES
TABULAR DATA
1. Measurement/Data Processing Systems: Primary - FChart: proprietary EAW software; Secondary - Brüel & Kjær 2012.
2. Microphone Systems: Earthworks M30; Brüel & Kjær 4133
3. Measurements: Dual channel FFT; length: 32 768 samples; sample rate: 48 kHz; logarithmic sine wave sweep.
4. Measurement System Qualication (includes all uncertainties):SPL: accuracy +/-0.2 dB @ 1 kHz, precision +/-0.5 dB 20 Hz to 20 kHz, resolution 0.05 dB; Frequency: accuracy +/-1 %, precision +/-0.1
Hz,resolutionthelargerof1.5Hzor1/48octave;Time:accuracy+/-10.4μs,precision+/-0.5μs,resolution10.4μs;Angular:accuracy+/-1°,precision+/-0.5°,resolution0.5°.
5. Environment: Measurements time-windowed and processed to eliminate room effects, approximating an anechoic environment. Data processed as anechoic or fractional space, as noted.
6. Measurement Distance: 7.46 m. Acoustic responses represent complex summation of the subsystems at 20 m. SPL is referenced to other distances using the Inverse Square Law.
7. Enclosure Orientation:Forbeamwidthandpolarspecications,asshowninMechanicalSpecicationdrawing.
8. Volts: Measured rms value of the test signal.
9. Watts:Peraudioindustrypractice,“loudspeakerwatts”arecalculatedasvoltagesquareddividedbyratednominalimpedance.Thus,thesearenotTrueWattunitsofenergyasdened
by International Standard.
10. SPL: (Sound Pressure Level) Equivalent to the average level of a signal referenced to 0 dB SPL = 20 microPascals.
11. Subsystem: This lists the transducer(s) and their acoustic loading for each passband. Sub = Subwoofer, LF = Low Frequency, MF = Mid Frequency, HF = High Frequency.
12. Operating Mode:Userselectablecongurations.Betweensystemelements,acomma(,)=separateamplierchannels;aslash(/)=singleamplierchannel.DSP=DigitalSignalProcessor.
IMPORTANT:Toachievethespeciedperformance,thelistedexternalsignalprocessingmustbeusedwithEAW-providedsettings.
13. Operating Range: Range where the processed Frequency Response stays within -10 dB SPL of the power averaged SPL within this range; measured on the geometric axis. Narrow band
dips are excepted.
14. Nominal Beamwidth: Design angle for the -6 dB SPL points, referenced to 0 dB SPL as the highest level.
15. Axial Sensitivity: Power averaged SPL over the Operating Range with an input voltage that would produce 1 W at the nominal impedance; measured with no external processing on
the geometric axis, referenced to 1 m.
16. Nominal Impedance: Selected 4, 8, or 16 ohm resistance such that the minimum impedance point is no more than 20% below this resistance over the Operating Range.
17. Accelerated Life Test:MaximumtestinputvoltageappliedwithanEIA-426Bdenedspectrum;measuredwithrecommendedsignalprocessingandRecommendedProtectionFilter.
18. Calculated Axial Output Limit: Highest average and peak SPLs possible during the Accelerated Life Test. The Peak SPL represents the 2:1 (6 dB) crest factor of the Life Test signal.
19. High Pass Filter: This helps protect the loudspeaker from excessive input signal levels at frequencies below the Operating Range.
GRAPHIC DATA
1. Resolution:Toremoveinsignicantnedetails,1/12octavecepstralsmoothingwasappliedtoacousticfrequencyresponsesand1/3octavecepstralsmoothingwasappliedtothebeamwidthand
impedance data. Other graphs are plotted using raw data.
2. Frequency Responses: Variation in acoustic output level with frequency for a constant input signal. Processed: normalized to 0 dB SPL. Unprocessed inputs: 2 V (4 ohm nominal impedance), 2.83 V (8
ohm nominal impedance), or 4 V (16 ohm nominal impedance) referenced to a distance of 1 m.
3. Processor Response: The variation in output level with frequency for a constant input signal of 0.775 V = 0 dB reference.
4. Beamwidth:Averageangleforeach1/3octavefrequencybandwhere,startingfromtherearoftheloudspeaker,theoutputrstreaches-6dBSPLreferencedto0dBSPLasthehighestlevel.Thismethod
means the output may drop below -6 dB SPL within the beamwidth angle.
5. Impedance: Variation in impedance magnitude, in ohms, with frequency without regard to voltage/current phase. This means the impedance values may not be used to calculate True Watts (see 9 above).
6. Polar Data: Horizontal and vertical polar responses for each 1/3 octave frequency band 100 Hz to 16 kHz or Operating Range.
VFS220i Specifications
Eastern Acoustic Works • One Main Street • Whitinsville, MA 01588 • tel 800 992 5013 / 508 234 6158 • fax 508 234 8251 • www.eaw.com
August 2013Part Number: RD0752 Rev 100EAW products are continually improved. All specications are therefore subject to change without notice.
INPUT PANEL SIGNAL DIAGRAM
LEGEND
DSP: EAW UX8800 Digital Signal Processor –or– Integral Digital Signal Processing for NT products.
HPF: High Pass Filter for crossover –or– Recommended High Pass Filter.
LPF: Low Pass Filter for crossover.
LF/MF/HF: Low Frequency / Mid Frequency / High Frequency.
AMP: User Supplied Power Amplifier –or– Integral Amplifier for NT products.
XVR: Passive LPFs, HPFs, and EQ integral to the loudspeaker.
EAW Focusing: Digital Signal Processor capable of implementing EAW Focusing.
DSP
EQ
HPF
LPF
AMP
1-Way, Single-Amp (LF1/LF2)
LF
LF
−
THIS PRODUCT HAS M10 MOUNTING POINTS. SEE OWNER’S MANUAL.
PIN 1−...−
PIN 1+...+
+
REV: DESCRIPTION:
REVISIONS
A00 NEW ISSUE PER ECOWHT8165 MJC
DWG SPEC/INPUT RATH
SCALE:
2037638-SD
MJC 12/6/11
DRAWING NUMBER:
DATE:
DRAWN BY:
1 of 1
1:1
REV:
A00
LOUD TECHNOLOGIES INC, ALL RIGHTS RESERVED
ONE MAIN STREET, WHITINSVILLE, MA 01588 USA
LOUD Technologies Inc.
TITLE:
SHEET:
ADOBE ILLUSTRATOR
PRELIMINARY
Table of contents
Other EAW Subwoofer manuals