DEHUMIDIFIER CONTROL PANEL
P
Control buttons
o
POWEROD
4
Press to turn the dehumidifier on and off. The
power indicator light blinks slowly when the
CONTINUE
POWER
power is first connected but the unit is off.
•
It illuminates (green) when the power button is
pressed and the dehumidfier is switched on.
WATER FULL
If the Humidity/Temperature sensor malfunctions
..f'
.
-
it blinks rapidly (several times a second).
Continuous operation
I
When pressed the continue light is illuminated
and the dehumidifier will operate continuously
for continuous dehumidification whatever the
humidity. The Humdity set buttons cannot be used
when Continuous operation is on.
@
Humidity Setting Control
The humidity level can be set within a range of
35%RH(Relative Humidity) to 80%RH(Relative
Humidity) in 5% increments.
Fig.2
For drier air, press the ® pad and set to a lower
percent value(%).
For damper air, press the q) pad and set a
higher percent value(%).
The machine will then turn on and off automatically
to maintain the selected level.
0
Display
Shows the setting control % humidity level while adjusting, then shows the actual room % humidity level
(+1-
5% accuracy).
Error Codes:
El-
Humidity sensor error--Unplug the unit and plug it back in. If error repeats, call for service.
E2.
Temperature sensor error-- Unplug the unit and plug it back in. If error repeats, call for service.
P1-
Unit is defrosting-- Adlow the unit time to automatically defrost. The error will clear after the unit self defrosts.
P2-
Bucket is full-- Empty the bucket and replace in the right position - the error will reset after a few seconds.
NOTE:
When more than one errors occur, the priority of the code display order is:
P2--E2--E1 --P1.
Other indicators & features of the dehumidifier
Water Full Light
Glows when the water bucket is full, whilst the bucket is
removed and if the bucket is not replaced in the proper position
The water level control float stops the dehumidifier when
the bucket is full, or when the bucket is removed or not replaced
in the proper position.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will
cycle off and the fan will continue to run until the frost disappears.
Wait 3 minutes before resuming operation
After the unit has stopped (other than tank full), it
will not restart for approx. 3 minutes. This is to protect
the unit and is not a fault. Operation will automatically
restart after 3 minutes.
Auto-Restart after power interruption
If the power is interrupted to the unit then when it
comes back on the machine will restart automatically
in the same mode as was set prior to the power
outage.