@2021 EcoAir - V1.4 Page 10 All rights reserved
OPERATION
TIMER
SETTING TIMER OFF
Press the "TIMER" Key to select your
desired running me
• Whilst the dehumidier is in
operaon press the mer
buon to set the dehumidier
to turn o aer a set interval
between 0-24hrs (1hr Incre-
ments)
• Once set, the mer LED will
remain on unl the set interval
is met and the dehumidier
turns o.
• Once the dehumidier is
switched o, wait 3 minutes
before resuming operaon.
SETTING TIMER ON
Pre set Timer Funcon:
• Whilst on Standby mode (--) press the mer buon
to set the dehumidier to come on aer a set
intervals between 0-24hrs.
• So long as the dehumidier is plugged into the
mains, the dehumidier will switch ON aer the
selected me has lapsed.
• The dehumidier will operate at the selected
sengs before the dehumidier was placed on
standby mode. It will connue dehumidifying unl
the humidity seng is reached, the sengs are
changed, water tank is full or unit switched OFF.
• If the set humidity is higher than the ambient
humidity the dehumidier will turn on however will
not dehumidify the air unl the humidity sengs
are adjusted.
Note: Wait 3 minutes before resuming operaon. Aer
the dehumidier has stopped (other than tank full) it
will not restart for approximately 3 minutes. This is to
protect the dehumidier and is not a fault. Operaon
will automacally restart aer 3 minutes.
TANK FULL INDICATOR
• Indicator lights up when water tank is
full or incorrectly inserted. The dehu-
midier will automacally switch o.
The indicator light will turn red and the
dehumidier will sound 3 beeps.
• Remove water tank, empty and rein-
state correctly.
Note:
• During Sleep mode the 3 beeps will not sound.
• When the water tank is full or removed, the controls
are disabled.
USEFUL INFORMATION
• When you rst use your dehumidier set to laundry
mode to reduce the humidity quickly to your de-
sired level. As the humidity seles, use the low fan
seng.
• When you set the Timer O, the dehumidier may
turn o prior to the set interval if it has reached the
set humidity.
• To cancel the mer seng press the Timer buon
unl you reach “00”.
• Auto Restart - Once the power is restored aer a
power failure, the appliance will connue to
operate at the selected sengs prior to the power
failure.
• Auto Defrost / Protecon - When frost builds up on
the evaporator coils, the compressor will cycle o
and the fan will connue to run unl the frost
disappears.
• Auto shut o - The dehumidier will automacally
switch o when the tank is full or removed and
when humidity seng is reached.