Ecosense RadonEye User manual

User Guide
Digital Radon Gas Monitor
RadonEye™

At Ecosense, we develop the highest performing, most innovative radon
monitoring solutions to ensure maximum indoor air awareness and safety for
your family.
About RadonEye
The first radon result is available in 10 minutes and a reliable average result is
produced within an hour. The RadonEye is more accurate than other home
monitors with an industry leading radon counting efficiency of 30 counts per
hour per pCi/L - 15 times more sensitive than the industry standard. The
sensor’s quick response allows users to see in real time when radon levels rise.
The RadonEye is easily set up using Bluetooth to the user’s smartphone. The
built-in OLED display shows the last measurement taken and scrolls through
averages determined over longer periods of time.
What is radon gas?
Radon is a naturally occurring radioactive gas that comes from the breakdown
of uranium and radium found in soil and rock all over the world. After entering
buildings through cracks and holes in the foundation, it decays into radioactive
particles that can become trapped in your lungs when you inhale. A known
human carcinogen, radon exposure is the leading cause of lung cancer in
nonsmokers, attributable to 21,000 lung cancer deaths in the United States
each year. While elevated radon may be more common in some areas, any
building can have a problem. The only way to know is to test. The World Health
Organization (WHO) and the U.S. EPA recommended ALL buildings be tested
regardless of where you live. If radon levels are high, they can affordably be
reduced by a certified radon mitigation professional. EPA guidance suggests
mitigating if levels are at or above 4 picocuries/liter (148 Becquerels/meter³).
More information on how to fix your home can be found at "Consumer's Guide
to Radon Reduction: How to Fix Your Home"
at www.epa.gov/radon/consumers-guide-radon-reduction-how-fix-your-home
Introduction
English

What’s in the Box
12V Power Cord Calibration CertificateRadonEye
Movement indicator
Radon level reading
Information & status
Bluetooth connection
LED indicator
RadonEye’s LED display
English

RadonEye Setup
1. Make sure your windows and doors are closed
for accurate radon measurement.
2. Connect the power cord to turn the device on.
3. Download and launch the Ecosense RadonEye app.
Allow RADONEYE to
access photos, media, and
files on your device?
Deny Allow1 of 2
Allow RADONEYE to
access this device’s
location?
Deny Allow1 of 2
4. For Android users, notification for file access is required for
exporting data and notification for location access is required when
Bluetooth is in use. Tap "Allow" when prompted with messages such
as "Allow RADONEYE to access photos, media, and files on your
device?" and “Allow RADONEYE to access this device’s location?”
5. Turn Bluetooth on to pair your phone with RADONEYE.
After pairing, your RADONEYE stays paired until you
unpair RADONEYE.
English

6. The values of current measurements will be displayed in 10-minute
intervals and an average value will be logged every 60 minutes into your app.
When the measured result is greater than the 4pCi/L (148Bq/㎥) EPA action
radon level, an alarm will sound if it is enabled.
1. Please click the “DATA” tab.
2. Click the chart area to load data from the
device.
3. Click the “Save Current Log Data” button to
save the data.
4. Name the file and click “Save”.
5. Click “Yes” to open the data or click “No” to
save the data to the app. The saved data can
be found later in the “Saved Log Data” menu.
6. Click the Export button in the upper right
corner and select the desired export option.
(Email, message, local folder, note, etc.)
How to save data
English

Ecosense Support
We are happy to help and can be reached via email at:
Monday - Fridays, 8am to 5pm Pacific Time Zone (Except holidays)
RadonEye is based on a dual-channel pulsed ion chamber system with a
highly accurate detection circuit. This innovative design delivers high
sensitivity levels which allows for first reliable radon data in just 1 hour
compared to 24 hours for other detection devices. (20 times faster than
any other consumer electronic radon measurement devices.) In addition,
the device provides a data logger, graphic display, and alarm setting to
your mobile device via Bluetooth technology (mobile app).
Radon Sensor: Pulsed ionization chamber
Radon Sensitivity: 30 CPH (Counts Per Hour) per 1 pCi/L
Radon Accuracy/Precision: < ±10% at 10 pCi/L after 10 hours
Radon Measurement Rate: Every 10 minutes
Radon Measurement Result: 60 minutes moving average
Measurement Range: 0.2 ~ 99.9 pCi/L (7~3,700 Bq/m³)
Connectivity: Bluetooth
Radon Alarm: Integrated audio alarm (configurable to set radon level)
Radon Level Visual Indicator: OLED display
Power Supply: 12V, 1A, Extend DC adapter
Data Storage Capacity: 1 year
Operating Range: 32°F~104°F (0~40℃), RH < 80%
Size: Φ80(mm) x 120(mm), 240g
Operating System: iOS 13 and Android 5.0 or later
Technical Specifications
English

Limited Warranty
RF Exposure Safety
This product is a radio transmitter and receiver.
It is designed not to exceed the emission limits for exposure to radio frequency (RF) energy
set by the Federal Communications Commission.
The antenna must be installed and operated with minimum distance of 8 inches (20 cm)
between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna
or transmitter.
The Ecosense RadonEye is intended for indoor use only. Avoid direct exposure to sunlight for
long periods. Avoid exposure to direct heat sources. For correct usage, make sure the product
is operating in the specified temperature range (see technical specifications).
Exposure to high humidity might permanently alter the product sensitivity or damage the
product. Do not disassemble. If the product does not work as specified or you are in doubt,
contact your local dealer or visit us at ecosense.io.
Use a dry cloth to clean the product.
Disposal: electronic equipment.
Safety and Maintenance
Ecosense warrants that its products shall substantially conform to its product specifications
and be free from defects in design, materials, and workmanship under normal use and
service for which the products were designed, for a period of twelve (12) months. This period
is calculated from the later of the date of purchase or delivery if ordered on the internet.
However, the warranty period may vary depending on the region or supplier.
See www.ecosense.io/support or contact Ecosense support at suppor[email protected] for
specific warranty and liability information relating to this product.
English

Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the Product.
This Product complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This Product may not cause harmful interference, and (2) this Product
must accept any interference received, including interference that may cause undesired
operation. This Product has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This Product
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this Product does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the Product and receiver.
—Connect the Product into an outlet on a circuit different from that to which
the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
Regulatory Compliance USA
English
FTLab co., LTD located at 503 ho, 8, 330 beon-gil, Haebong-ro, Ansan-si, Gyeonggi-do, Korea,
hereby declares that this Product complies with the provisions of the Radio Equipment
Directive (RED) 2014/53/EU and its amendment. The full text of the EU declaration of
conformity is available at: www.link.ecosense.io/doc-rd200.
Ecosense WEEE Reg. Nos.: DE13932546, FR281905_05LXSZ
EU Declaration of Conformity
Table of contents
Other Ecosense Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Helwett Packard
Helwett Packard 4339B user guide

Flexim
Flexim FLUXUS F704**-NN Series user manual

Sperry instruments
Sperry instruments SPR-300 PLUS A operating instructions

Dillenger
Dillenger KT-LCD3 user manual

Honeywell
Honeywell DVC100 (M) MK2 installation guide

AFL
AFL NOYES OFL280-10x quick start guide