Important Safety Information
Improper handling can cause serious damage to the EdgeStar dehumidifier and/or injury to the user. This
dehumidifier is designed for domestic indoor use only. Do not use the unit for industrial or commercial use. Any
other use may invalidate the warranty. Please review the ratings label located on the rear panel of the unit for
electrical and other technical data related to this unit. The unit must be connected to a properly grounded
wall outlet. Please read and follow the safety information listed below.
Electrical Safety
This dehumidifier is designed for indoor use
only. Do not use the unit near bath tubs,
swimming pools or other bodies of water.
Do not wet the housing or control panel.
Do not exceed the power outlet ratings.
Do not pull the unit by the cord.
Always turn the unit off and unplug it from the
outlet when cleaning.
Unplug the unit if it is not going to be used for
an extended time period.
Do not operate the unit with a power plug
missing the ground plug, a damaged cord or
a loose socket.
Be sure the dehumidifier is properly
grounded.
Never plug or unplug the unit with wet hands.
Do not bypass, cut or remove the grounding
plug.
Do not use extension cords or power strips
with this unit. You may need to contact your
electrician if it is necessary to use a longer
cord or do not have a grounded outlet. Do
not modify the power cord’s length or share
the outlet with other appliances. It is
recommended the unit be connected on its
own 15 Amp circuit.
Do not start or stop the unit by switching the
circuit’s power on and off.
If the power cord is damaged, it must be
replaced by the manufacturer or a qualified
technician.
Never open the unit while it is plugged in.
Immediately unplug the unit if it makes
strange sounds, emits smells or smoke comes
out of it, and contact customer service.
Do not remove any part of the casing unless
instructed by an authorized technician.
You should never attempt to repair the unit
y
ourself.
General Safety
This unit is not intended to be used by
children.
Children should be supervised to ensure that
they do not play with this product.
Do not allow children to play with the controls
or drop any objects into the air outlets or
vents.
Care should be taken when using the unit in
a room with infants, elderly persons, and
children.
Do not place flower vases, containers, or any
objects on top of the unit.
Do not allow anyone to sit on the unit.
Do not climb on or use the unit as a step.
Do not cover the air intake or exhaust vents
with towels, clothes or materials that prevent
air flow.
When using in closets or confined spaces, be
sure to keep doors open to allow proper
ventilation.
Do not use this appliance near flammable
gas or combustibles, such as gasoline,
benzene, thinner, etc.
Do not use in areas where chemicals are
handled.
Do not place the unit near a heat source as
doing so may cause the plastic parts to melt.
Only use in an upright position on a flat, level
surface and provide at least 10 inches of
clearance from any walls or objects.
Route the power cord carefully to avoid
creating a tripping hazard.
When using in closets or confined spaces, be
sure to keep doors open to allow proper
ventilation.
Clean the pre-filter regularly. A clogged pre-
filter can restrict proper airflow and reduce
the lifespan and/or efficiency of this unit.
Never run the unit without
p
re-filte
r
.
The water produced by the dehumidifier
is not potable or suitable for drinking.
Do not drink or use condensate or water
drained from the unit as it contains
contaminates and could make you sick.
Electrical products should not be disposed of
with household waste. Please contact your
local recycling center for more information on
how to recycle electronic waste.

EdgeStar Portable Dehumidifier ii
Table of Contents
IMPORTANT SAFETY INFORMATION................................................................. I
INTRODUCTION ................................................................................................... 1
PARTS IDENTIFICATION ..................................................................................... 2
BACK VIEW .......................................................................................................... 2
FRONT VIEW ......................................................................................................... 2
INSTALLATION INSTRUCTIONS ........................................................................ 3
CONTROL PANEL OVERVIEW ........................................................................... 4
OPERATING THE CONTROL PANEL ................................................................. 5
POWER ................................................................................................................ 5
Auto-Shut Off:.............................................................................................. 5
TIMER................................................................................................................... 5
FAN SPEEDS.......................................................................................................... 5
SETTING THE HUMIDITY LEVEL ................................................................................... 5
LCD DISPLAY ....................................................................................................... 6
Temperature and Timer Display ................................................................ 6
Humidity Level Display................................................................................ 6
Error Codes .................................................................................................. 6
WATER FULL LIGHT................................................................................................. 6
ADDITIONAL NOTES ABOUT THE DEHUMIDIFIER’S BEHAVIOR:......................................... 6
DRAINING THE UNIT............................................................................................ 7
PUMP DRAIN ........................................................................................................ 7
MANUAL DRAIN.................................................................................................... 8
CONTINUOUS GRAVITY DRAIN................................................................................ 8
MAINTENANCE .................................................................................................... 9
CLEANING THE UNIT ............................................................................................... 9
CLEANING THE PRE-FILTER ....................................................................................... 9
CLEANING THE WATER BUCKET ................................................................................ 9
PREPARATION FOR STORAGE ................................................................................ 10
AUTO-DEFROST................................................................................................... 10
ENERGY SAVING GUIDE................................................................................... 10
TROUBLESHOOTING ........................................................................................ 11
SPECIFICATIONS............................................................................................... 13

1
Introduction
Thank you for purchasing this EdgeStar portable dehumidifier. We are glad
you chose us. We believe that your purchase of this product opens a
relationship between you and EdgeStar. We will provide the customer
support needed to nurture that relationship.
This manual contains important information regarding the proper
installation, use and maintenance of your portable dehumidifier. Following
this manual will ensure that your product will work at its peak performance
and efficiency.
Your dehumidifier is designed to remove moisture from the air which can
then be collected into a removable bucket or drained by way of an
automatic pump and drain hose or a continuous gravity drain hose that
can be routed to a floor drain or other suitable drainage port.
Please save the original product packaging in case you need to safely
transport your portable dehumidifier.
For Your Records:
Please write down the model number and serial number
below for future reference. Both numbers are located
on the ratings label on the back of your unit and are
needed to obtain warranty service. You may also want
to staple your receipt to this manual as it is the proof of
your purchase, and is also needed for service under
your warranty.
Model Number:
Serial Number:
Date of Purchase:
To better serve you, please do the following before contacting customer
service:
If you received a damaged product, immediately contact the
dealer that sold you the product.
Read and follow this instruction manual carefully to help you install,
use and maintain your portable dehumidifier.
Read the troubleshooting section of this manual as it will help you
diagnose and solve common issues.
Register your product at http://www.edgestar.com and download
product guides, owner’s manuals, and access additional
troubleshooting resources.
If you need warranty service, our friendly customer service
or by telephone at 1 (866) 319-5473.

EdgeStar Portable Dehumidifier 2
Parts Identification
Back View
Front View
Water Level Indicator
Water Bucket
Air Intake
Control Panel
Handle
Exhaust
Gravity Drain Outlet
Casters
Pump Drain Outlet

3
Installation Instructions
You can use the EdgeStar dehumidifier to create a comfortable
environment and prevent damage caused by moisture to books or
valuables in areas such as basements or home libraries. Follow the
instructions below to unpack and set up your unit.
1. Carefully unpack the dehumidifier from its box and packaging
material, and remove any adhesive tape holding the water
bucket and filter in place. You may want to save the box for
storing and transporting the unit. Let the unit sit upright for at least
24 hours before powering it on to allow the compressor’s fluids to
settle.
2. Place the dehumidifier on a level floor or surface that is strong
enough to support the unit with a full bucket of water in a room
where the ambient temperature will not drop below 41°F, and
away from any heat sources such as direct sunlight, heaters,
radiators, dryers, etc.
Allow at least 10 inches of space all around the unit and at least 20 inches
of space above the unit.
If you have multiple power outlets in the room, choose one that is near the
dehumidifier and that will be able to provide adequate power to the unit.
See the power requirements listed in the product label located on the
side, or on the back of your dehumidifier.
3. Close all windows and doors. To be most effective, use the
dehumidifier in a contained room as opposed to a partitioned
studio or warehouse type space.
4. To activate the unit and ensure the warning switches are
engaged, remove the water bucket and reinstall it; otherwise, the
unit may not work properly.
5. Plug the unit in to a grounded outlet. (Read the Safety Information
section.)
Note:
Dehumidifiers working
in a basement will
have little or no effect
on adjacent enclosed
rooms such as closets,
unless there is enough
circulation of air in and
out of the enclosed
area.
The unit is designed to
work in environments
with temperatures
between 41°F and 95°F
Caution:
This unit is for freestanding,
indoor use only and will not
operate correctly if used
outdoors or if built in under a
counter or cabinet.

EdgeStar Portable Dehumidifier 4
Control Panel Overview
Button Function
Powers the unit on or off.
Adjusts the fan speed.
Activates the timer mode.
Increases the desired relative humidity setting for damper air.
NOTE: When in Timer Mode, this button will increase the Timer setting in
increments of 1 hour.
Decreases the desired relative humidity setting for drier air.
NOTE: When in Timer Mode, this button will decrease the Timer setting in
increments of 1 hour.
Adjusts temperature display to be shown in Celsius (ºC) or
Fahrenheit (ºF)
Indicator Light Function
Bucket Full Lights up to indicate that the water bucket is full and
must be emptied.
Timer Lights up to indicate that the unit is in timer mode.
High Speed Lights up to indicate the fan is on the high setting.
Normal Speed Lights up to indicate the fan is on the normal setting.
Defrost Indicator Lights up to indicate the auto defrost operation is on.
Display Function
Temperature/Timer
Display
Displays the current temperature. When adjusting the
Timer setting, displays the time setting in hours then
reverts back to current temperature after 10 seconds.
Humidity Level Display
Displays the level of humidity. Displays desired
humidity level when increasing or decreasing desired
level, then reverts to current humidity level after 10
seconds.
Note: The unit is not a
humidifier; using the
increase humidity button will
not add moisture to the air.

5
Operating the Control Panel
Use the Power button to turn the portable dehumidifier on and off. By
default when you first use the power button, the unit will begin to operate
in normal fan speed mode.
Auto-Shut Off: The unit will shut off when the set humidity has been
reached, or when the water bucket is full, has been removed, or is not in
its proper position.
The timer mode allows for continuous operation for a user defined set
number of hours.
To operate the unit in timer mode:
1. Make sure the power cord is plugged into a power outlet.
2. Press the Power button.
3. Press the Timer button to activate the timer mode. The Timer Mode
indicator located above the Timer button will light up green.
4. Press the Increase and Decrease buttons to set the desired number of
hours for the dehumidifier to run. The timer can be set in increments of
1 hour up to 24 hours. The timer setting display will flash for
approximately 10 seconds before reverting back to displaying the
current temperature.
5. To cancel or turn off the timer setting, adjust the increments by using
the Increase and Decrease buttons until 0 hours is shown on the
display.
The dehumidifier has two fan speeds. Use the high fan speed for maximum
moisture removal. Use the normal fan speed for quieter operation.
Select the fan speed by pressing the Fan button until desired mode is
illuminated
The desired humidity level can be set within a range of 30% Relative
Humidity (RH) to 90% RH in 5% increments.
To set the desired humidity level percentage:
1. Make sure the power cord is plugged into a power outlet.
2. Press the Power button.
3. Press the Increase and Decrease buttons to set the desired humidity
level. After approximately 10 seconds, the LCD display will revert to the
actual room humidity level with ±5% accuracy. For drier air use the
Decrease button.
Power
Timer
Fan Speeds
Setting the Humidity Level
Note: Relative Humidity (RH) is
the ratio of the actual water
content of the air at a given
temperature to the potential
water content at that same
temperature.

EdgeStar Portable Dehumidifier 6
Operating the Control Panel continued
There are 2 LCD displays located on the control panel of this unit.
Temperature and Timer Display
When operating normally, this will display the current temperature in the
room where the dehumidifier is located. When adjusting the timer setting,
this will display the hours remaining for the timer.
Humidity Level Display
When operating normally, this will display the current relative humidity in
the room where the dehumidifier is located. When adjusting the desired
humidity setting, this will display the desired humidity level setting.
Error Codes
In addition to showing the humidity, the display screens may show the
following error codes:
E1 – Temperature sensor error
E2 – Defrost sensor error
E3 – Humidity sensor error
For E1, E2 and E3 error codes, Power the unit off, and then unplug the unit
for 15 minutes. Plug in and power on. If the issue persists, please contact
customer service.
LO – Temperature too low error
Current room temperature is below 32°F. Make sure the ambient
temperature is suitable for the unit (41°F – 95°F). If the ambient
temperature is suitable, please contact customer service.
HI – Temperature too high error
Current room temperature is above 122°F. Make sure the ambient
temperature is suitable for the unit (41°F – 95°F). If the ambient
temperature is suitable, please contact customer service.
The Water Full Light will illuminate when the bucket is ready to be emptied.
The light also turns on when the bucket is not installed or if not installed
correctly. Once the water is drained, and the bucket is properly installed,
the light will no longer illuminate and the unit will operate normally.
Additional notes about the dehumidifier’s behavior:
Once the unit reaches the desired humidity level, the power button
will remain lit while the compressor and fan shut off.
When turning the unit off and back on in a normal manner the
dehumidifier will retain its last target humidity settings except In the
event of a power interruption (i.e. power outage or if unit is
unplugged).
If the unit is turned on when the room’s relative humidity is lower than
the desired humidity level, the unit will run for a short period of time
and then the compressor and fan will shut off.
LCD Display
Water Full Light

7
Draining the Unit
There are 3 different ways in which this dehumidifier can be drained:
pump drain, manual drain and continuous gravity drain. Please review
the below descriptions and instructions for each method to determine
which is best for your specific setup.
This dehumidifier comes with the built in pump that will engage
automatically to drain water into a floor drain or other suitable drainage
port. To setup the dehumidifier to utilize the built in pump please follow
the instructions below.
1. Locate the pump drain hose and insert firmly into pump drain
outlet on the lower left side of the back of the unit.
2. The drain hose will click into place when attached properly.
3. Place the other end of the drain hose in a floor drain or other
suitable drainage port.
4. Operate unit in normal manner.
5. To remove pump drain line, press the release button located
directly above the pump outlet.
NOTE: If the pump drain hose has not been connected properly, the
unit will not activate the pump feature. A sensor is located at the
pump drain hose connection to detect if the hose has been properly
connected. There will be an audible ‘click’ that can be heard when
inserted properly. Once connected properly, the dehumidifier will
automatically switch to using the drain pump.
Pump Drain
Note: The pump will not be
activated if the water bucket is
full or not installed properly.
Please empty the water bucket
and re-install properly before
usin
g
the
p
um
p
drain feature.
Note: The pump is capable of
pumping water up to 16ft
vertically or horizontally.

EdgeStar Portable Dehumidifier 8
The dehumidifier can be drained manually using the water bucket. When
the bucket is full, the unit will automatically stop running, and the Bucket
Full light will illuminate. Follow the below steps to remove the bucket and
dump the water.
1. Slowly and carefully pull the bucket out by the handles and lift
upward to remove.
2. Use both hands to carefully empty the water bucket.
3. Reinstall Bucket. Please note that this unit is designed to not
operate if the water bucket has not been installed properly.
Additional notes when emptying the water bucket.
-Do not place the bucket on the floor as its bottom is uneven and will not
stand upright on its own.
-There is a carrying handle located inside the water bucket that can be
used as needed for carrying the water bucket.
The dehumidifier can be drained continuously to a suitable floor drain by
using the gravity drain port. In order to utilize the continuous gravity drain
you will need to supply a suitable drain hose. You may use a standard
garden hose with a ¾” connector fitting.
1. Locate the gravity drain hose port found on the back of the unit
(located on the middle, right hand side)
2. Unscrew the drain cover by turning counter clockwise and remove
the rubber stopper.
3. Screw the drain hose onto the threaded portion of the drain outlet
and tighten firmly.
4. Place the other end of the drain hose in a floor drain or other
suitable drainage port. Drain must be located below the level of
the drain outlet on the back of the unit to allow for proper gravity
drainage.
Manual Drain
Continuous Gravity Drain
NOTE: Continuous gravity drain
hose not included, must be
provided separately. A
dehumidifier drain hose or
standard garden hose with a
¾” fitting is required. As with
all hose attachments, ensure
that a rubber gasket is
installed in the hose fitting in
order to prevent leaks.
Warning: The water produced
by the dehumidifier is not
potable or suitable for
drinking.
Do not drink the water
drained from the unit as it
contains contaminates that
could make you sick.

9
Maintenance
Clean the dehumidifier and pre-filter regularly to maintain performance
and efficiency and to prolong the unit’s life. Be sure to always unplug the
dehumidifier from the power outlet before cleaning.
Use a soft dry cloth to wipe the body clean. If necessary, use lukewarm
water to dampen a cloth to clean the unit. Use a soft bristle brush and
vacuum cleaner to clean between the air intake and exhaust vents.
Never use abrasive chemicals, volatile substances, gasoline, detergents,
chemically treated cloths, or other cleaning solvents that may damage
the cabinet exterior.
Never spray water directly on the unit.
Clean the pre-filter periodically to prolong the unit’s life, and keep the unit
running efficiently. Lint, dust, and dirt can clog the unit and reduce its
performance and effectiveness. If the unit is used in a dusty environment
you may need to clean the pre-filter on a weekly basis.
To clean the pre-filter, follow the steps below:
1. Power off the unit, remove the water bucket and then remove the
pre-filter as shown below.
2. Use a vacuum cleaner or tap the filter lightly to remove loose dust
and dirt, then rinse thoroughly under lukewarm running water
(below 104°F). You may use a mild soap and water solution if
needed. Allow the pre-filter to air dry in a cool and shaded place.
Dry thoroughly before reinstalling.
3. Reinsert the pre-filter.
Warning: Never operate the unit without the pre-filter.
Wash the water bucket frequently to prevent the growth of bacteria,
mildew and mold.
To clean the water bucket, follow the steps below:
1. Remove the water bucket from the unit.
2. Wash the bucket with clean water and a mild detergent. Rinse the
bucket thoroughly.
3. Install the water bucket.
Cleaning the unit
Cleaning the pre-filter
Cleaning the water bucket
NOTE: Do not put the filter in a
dishwasher.
NOTE: Do not put the water
bucket in a dishwasher.
IMPORTANT: On a regular basis
it is required that the pre-filter
be inspected for buildup of
lint, dust and other materials.
A clogged pre-filter can
restrict proper airflow and
cause undue strain on the
mechanical components of
your dehumidifier resulting in
reduced performance and
shorter
p
roduct lifes
p
an.

EdgeStar Portable Dehumidifier 10
Maintenance continued
If you are not going to be using the unit for an extended period of time,
follow the instructions below before storing your unit:
1. Turn the unit off, unplug and wait 24 hours before emptying the
water bucket to allow for excess moisture to drain into the bucket.
2. Drain all water from the water tank.
3. Clean the air filter, water tank and unit.
4. Unplug and carefully wind the power cord.
5. Cover the unit with a plastic bag.
6. Store the unit in an upright position in a dry, well-ventilated place.
When the unit is operated in temperatures below 54°F the surface of the
evaporator may accumulate a layer of frost which will reduce the
efficiency and effectiveness of the dehumidifier. When this occurs, the
unit will automatically activate its auto-defrost feature. The time required
to complete the auto-defrost cycle varies and is dependent on the
ambient temperature and relative humidity of the operating environment.
The auto-defrost indicator located on the control panel will light up when
the auto-defrost feature is running.
Note: Do not operate this dehumidifier in temperatures below 41°F
Energy Saving Guide
Read and follow the below energy saving tips to get the best
performance and efficiency from your portable dehumidifier:
Do not cover the air outlet (exhaust) while in use.
Do not place the unit in front of curtains or drapes - to ensure they do
not obstruct the air intake.
Keep curtains, blinds or drapes closed during the sunniest part of the
day.
Close all windows and doors.
Indoor relative humidity should ideally be kept between 35 and 60
percent depending on the ambient temperature.
Make sure the unit is on a level surface.
To prolong the compressor's life, please wait at least 3 minutes before
turning the unit back on after shutting it off.
Inspect and keep the pre-filter clean by cleaning regularly.
Perform routine maintenance.
Preparation for Storage
Auto-Defrost

11
Troubleshooting
Follow the troubleshooting chart to resolve common issues.
Issue Possible Cause Solution
My dehumidifier does
not dry the air
Insufficient time to dry Run the unit for a
longer period of time.
Air intake or exhaust
vents are blocked
Make sure there are no
towels, curtains, or
furniture blocking the
front and back of the
unit.
Humidity control may
not be set low enough
Lower the desired
humidity setting.
Opened windows or
doors
Close all windows and
doors.
Room temperature is
too low (below 41ºF)
Increase the room
temperature.
There is a kerosene
heater or other device
giving off water vapor
in the room
Remove any device
producing water
vapor.
Frost appears on the
coils This is normal behavior
The dehumidifier has
an auto-defrost
feature.
My dehumidifier is not
functioning at all
Unit is not receiving
power
Make sure the unit is
plugged in.
Insufficient power
Move the unit to
another outlet. Check
your circuit breaker.
(Refer to the rating
label on the back of
the unit to determine
the Amperage draw).
Water bucket is full Drain the water bucket
and restart.
Water bucket is not in
proper position
Remove bucket and
reinsert.
Control panel is not
functioning
If no indicator lights
turn on, contact
customer service.
My dehumidifier is
making a loud noise
Air filter is clogged Clean the air filter.
A foreign object has
jammed the fan
Shut off the unit, and
remove the object
from the fan.
The floor below the unit
is uneven
Move the unit to a
level surface.
My dehumidifier is
making a continuous
metallic knocking or
pinging sound
Unit may have been
shipped on its side
Shut off the unit. Let
the unit sit on a level
surface for at least 24
hours and restart.
Damaged compressor Contact customer
service.

EdgeStar Portable Dehumidifier 12
Troubleshooting continued…
My dehumidifier is
leaking
A drain hose has been
attached and is loose
Secure the drain hose.
Route your drain hose
to a floor drain or other
suitable drainage port.
Cracked water bucket Contact customer
service.
My dehumidifier runs
for a little while and
then it trips the power
cord or the circuit
breaker
The dehumidifier may
be plugged into an
outlet that cannot
supply the correct
amount of electrical
current
Contact an electrician
if the unit works in a
different room or on a
different circuit.
The control panel lights
blink randomly
Unit may have a faulty
control panel
Restart the unit, and if
issue persists, contact
customer service.
Unit has an “E1” Error Temperature sensor
error
Restart the unit, and if
issue persists, contact
customer service.
Unit has an “E2” Error Defrost sensor error
Restart the unit, and if
issue persists, contact
customer service.
Unit has an “E3” Error Humidity sensor error
Restart the unit, and if
issue persists, contact
customer service.
Unit has a “LO” error
Current room
temperature is below
32°F
Make sure the ambient
temperature is suitable
for the unit (41°F –
95°F). If the ambient
temperature is suitable,
please contact
customer service.
Unit has a “HI” error
Current room
temperature is above
122°F
Make sure the ambient
temperature is suitable
for the unit (41°F –
95°F). If the ambient
temperature is suitable,
please contact
customer service.

13
Specifications
Description of product Portable Dehumidifier
Model DEP700WP
Voltage/Frequency AC 115V~60Hz
Power Consumption 862W
Operating Current 7.5A
Water Bucket Capacity 8.5 Liters / 2.25 Gallons
Dehumidifying Capacity @ 80F
RH60% 70 Pints/Day
Refrigerant R410A
Dimensions
W x D x H 15 1/4” x 11 1/8” x 23 3/4”
Weight 44 lbs.

EdgeStar Limited
Warranty
One (1) Year Parts & Ninety (90) Days
Labor
This product is warranted by EdgeStar to be free from defective workmanship and materials, subject to any conditions
set forth as follows:
WHAT IS COVERED:
LABOR: For a period of NINETY (90) DAYS from the date of original purchase, labor will be performed free of charge at
an authorized EdgeStar repair facility. At its option, EdgeStar will repair the product with new or remanufactured parts,
or exchange the defective product with a new, refurbished, or remanufactured product. If a product is replaced, it will
carry the remaining warranty of the original product. After the ninety (90) day period, EdgeStar will no longer be
responsible for labor charges incurred. All defective products and parts covered by this warranty will be repaired or
replaced on a mail-in basis to an EdgeStar authorized repair facility.
PARTS: For a period of ONE (1) YEAR from the date of original purchase, EdgeStar will supply new, rebuilt, or
refurbished parts free of charge. EdgeStar may request a defective part be returned in exchange for the replacement
part. All replacement parts or products will be new, remanufactured, or refurbished. All products and parts replaced by
EdgeStar under warranty service become the property of EdgeStar.
This warranty applies to the original purchaser only, and only covers defects in workmanship experienced during
operation of the product under normal service, maintenance, and usage conditions. This warranty applies to the
purchase and use of this product in residential settings within the United States of America.
WHAT IS NOT COVERED:
The following limitations apply to the coverage of this warranty. This warranty does not cover:
Labor charges for installation, setup or training to use the product.
Shipping damage, and any damage caused by improper packaging for shipment to an authorized service center, and any
damaged caused by improper voltage or any other misuse, including abnormal service, handling, or usage.
Cosmetic damage such as scratches and dents.
Normal wear and tear on parts or replacement of parts designed to be replaced, e.g. filters, cartridges, batteries.
Service trips to deliver, pick-up, or repair, install the product, or to instruct in proper usage of the product.
Damages or operating problems resulting from misuse, abuse, operation outside environmental specifications, uses
contrary to instructions provided in the owner’s manual, accidents, acts of God, vermin, fire, flood, improper installation,
unauthorized service, maintenance negligence, unauthorized installation or modification, or commercial use.
Labor charges incurred 91 days or more after the date of original purchase.
The use of EdgeStar products in commercial settings.
Optional accessories, attachments, and appearance items.
Products that have been modified to perform outside of specifications without the prior written permission of EdgeStar.
Products lost in shipment, or theft.
Products sold AS IS or from an unauthorized reseller.
Products that have had their serial numbers removed or defaced. Products with serial numbers that have been invalidated.
OBTAINING WARRANTY SERVICE:
If you believe your product is defective, contact EdgeStar Customer Support for troubleshooting assistance and
warranty service at 1-866-319-5473. Please have your serial number and proof of purchase available. Once an
EdgeStar authorized representative has confirmed that your product is defective and eligible for warranty service, the
product must be returned to an EdgeStar repair facility. The purchaser is solely responsible for prepaying all shipping
related costs to and from the repair facility. EdgeStar is not responsible for damage resulting from shipper mishandling
or improper packaging. Do not return a defective product to the place of purchase. Products received without a return
authorization number will be refused.
THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION,
ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TO THE EXTENT ANY IMPLIED
WARRANTY IS REQUIRED BY LAW, IT IS LIMITED IN DURATION TO THE EXPRESS WARRANTY PERIOD ABOVE. NEITHER
THE MANUFACTURER NOR ITS DISTRIBUTORS SHALL BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL, INDIRECT,
SPECIAL, OR PUNITIVE DAMAGES OF ANY NATURE, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR PROFITS,
OR ANY OTHER DAMAGE WHETHER BASED IN CONTRACT, TORT, OR OTHERWISE. SOME STATES DO NOT ALLOW THE
EXCLUSION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY HAVE OTHER RIGHTS THAT VARY FROM STATE TO
STATE.

EdgeStar Products
500 N. Capital of TX Hwy, Bldg 5
Austin, TX 78746
Toll Free: 1-866-319-5473
Web: http://www.edgestar.com
E-mail: service@edgestar.com
Register your product, download owner’s manuals, access additional troubleshooting
resources, and obtain more information on other great EdgeStar products on the web at:
http://www.edgestar.com
Product contents and specifications may change without
notice.
Copyright © 2015 Living Direct, Inc. All rights
reserved.
Table of contents
Other EdgeStar Dehumidifier manuals