Programming
Programming The User Code(Program Number 1):
30 user can have different codes. Each code must be at least 3, at most 8 characters long. Main password can't be
erased. It can only be changed. To change the main password, enter 00 in sequence number section. Press 'Password'
and '#' keys to activate system.(Door is opened.)
Step DATA entered Description
1
2
3
4
5
6
* *Main code * *
1
Sequence number #
User Code #
User Code #
#
Enter programming menu. Green LED flashes slowly.
Select program 1 using '1' key (Programming user code).
Led starts blinking fast.
Led flashes for 2sec, then starts blinking fast. Seq. number can be
between 01 and 30 .00; is the sequence number of the main code.
Led flashes for 2sec then starts blinking fast
Led flashes for 2 sec then blinks slowly, getting back to the
program menu
Exit programming menu.
(Same code)
For example;
Let's program code 2345 for user number 5.
Enter program mode by **1234** .Press the following keys in sequence.
1, 05# , 2345# ,2345# ,#
Erasing The User Code(program number 1):
Step DATA entered Description
1
2
3
4
5
6
* *Main code * *
1
Sequence number #
#
#
#
Enter program menu. Green LED blinks slowly.
Select program 1 using '1' key (Programming user code).
Led starts blinking fast..
Led flashes for 2sec, then starts blinking fast. Seq. number can be
between 01 and 30.
Led flashes for 2sec then starts blinking fast
Led flashes for 2 sec then blinks slowly, getting back to the
program menu
Exit programming menu.
ACCESS KEYPAD
SK-30 ACCESS KEYPAD
SK-30
4858
Programming
Programming Relay Time (Program Number 2):
Relay time can be programmed between 01 and 98
If relay time is set as 99 ON/OFF mode is selected. When this mode is selected, entering the code opens the relay lock if it
is closed and vice versa. If magnetic contact will be operated in ON/OFF mode, 12 VAC voltage should be applied to the
lock.
Step DATA entered Description
1
2
3
4
* *Main code * *
2
Time #
#
Enter programming menu. Green LED flashes slowly.
Pressing '2' key, enter Relay time programming.
Led starts blinking fast.
Time; can be between 01 98sec. IF time data is set as 99, then this
is ON/OFF mode. Led blinks slowly, getting back to program menu.
~
Led flashes for 2sec then starts blinking fast
Example;
NOTICE
If desired relay time is 45 sec, enter program menu using 1234 ,press the
following keys in sequence : 2, 45#, #
: for 5 seconds, it should be entered as 05 in time section.
Programming Panic (Program Number 3):
To generate silent alarm # and keys are pressed simultaneously. As a result of this operation, panic output is activated
according to the mode which was programmed before. Panic mode can be programmed in 3 different ways.
1-Panic output is active until user code is entered.
2-Panic output is active for 1 secretary..
3-Panic output is active until key is pressed.
Step DATA entered Description
1
2
3
4
* *Main code * *
3
Panic Mode #
#
Enter programming menu. Green LED flashes slowly.
Panic Mode programming is selected. Led blinks fast.
Mode; can be 1,2 or 3 r.
If Mod=1 then ;Panic output is active until user code is entered.
Mod= 2 ;Panic output is active for 1sec.
Mod= 3; until key is pressed Panic output is active.
Led blinks slowly, getting back to program menu.
Led flashes for 2sec then starts blinking fast
For example;
Let’s programme panic output is active for 1sec
Enter program mode by **1234** .Press the following keys in sequence.
3, 2# ,#
(1,2 or 3)