EDS SK-30 User manual

KK-SK30/063001/1
f:/p/kk/eds/e/sk30e1
88
SK-30
ACCESS KEYPAD
INSTALLATION MANUAL
SERVICE
EDS Elektronik Destek
Sanayi ve Ticaret Ltd. Þti.
Meclis Mah. Teraziciler Cad.
Kýlýç Sok. No:4 34785
Sarýgazi/ Ýstanbul
www.eds.com.tr [email protected]
+90 216 528 45 00
+90 216 314 17 80
Tel.
Fax
:
:

ACCESS KEYPAD
SK-30 ACCESS KEYPAD
SK-30
Features
Microprocessor control
User password
Number of password characters
Main password
Erase main password
Erase user passwords
Erase all user passwords
Keypad
Keypad type
Outputs
Output connectors
Relay output duration (/time?)
Programmable panic alarm
Panic output activation using and # keys
Trap number (special code under threat)
Lighting
Buzzer
Display
Return to factory default settings
Power supply voltage
Power consumption
Power consumption
Main body
Dimensions
Weight
Operation temperature
Available
30 users.
8 characters(max)
Available
N/A.
Available
Available
Built-in
Silicone keypad
Programmable relay, Panic
Cable
1~98 sec
Available
Available
Available
Automatic
Available
3 LEDS
Available
12VDC/24VDC selectable
0.21W (10mA) (normal)
0.75W (65mA) (when relay is used)
ABS plastic
113X113X23mm
165gr.
-10 C +55 C°~ °
MAIN PASSWORD
RELAY TIME
PANIC MODE
TRAP NUMBER
1234
2sec
2
0
Factory Default Settings
2878
Note

ACCESS KEYPAD
SK-30
Connection
6838
ACCESS KEYPAD
SK-30
Programming
Erasing all codes - except main code (Program Number 4):
Step DATA entered Description
1
2
3
4
5
* *Main code * *
4
** #
Main Code #
#
Enter programming menu. Green LED flashes slowly.
Select user code erase program. Led blinks fast.
Select all user codes erase. Led blinks fast.
All user codes except program code are erased .Led blinks slowly ,
getting back to program menu.
Exit programming menu.
Trap number programming( program number 5):
Trap number is programmed as described below. Trap number can be programmed as any number between 0 and 9.
When under threat panic can be activated entering the code and pressing trap number and '#''.
Step DATA entered Description
1
2
3
* *Main code * *
5
Trap Number #
Enter programming menu. Green LED flashes slowly.
Select trap number programming. Led blinks fast.
Trap number can be between 0 and 9. Led blinks slowly,
getting back to the programming menu.
Led flashes for 2sec then starts blinking fast
4#
RESETTING PROCEDURE:
When there is a confusion or the password is forgotten, you can return to factory default settings. to get back to
factory settings, follow these steps:
1- Cut off power. Short-circuit JP1.
2- Supply power.
3- When led flashes open-circuit JP1.
4- press 1234 keys in sequencer.
5- green led flashes for 2sec. Factory settings are restored

Programming
Programming The User Code(Program Number 1):
30 user can have different codes. Each code must be at least 3, at most 8 characters long. Main password can't be
erased. It can only be changed. To change the main password, enter 00 in sequence number section. Press 'Password'
and '#' keys to activate system.(Door is opened.)
Step DATA entered Description
1
2
3
4
5
6
* *Main code * *
1
Sequence number #
User Code #
User Code #
#
Enter programming menu. Green LED flashes slowly.
Select program 1 using '1' key (Programming user code).
Led starts blinking fast.
Led flashes for 2sec, then starts blinking fast. Seq. number can be
between 01 and 30 .00; is the sequence number of the main code.
Led flashes for 2sec then starts blinking fast
Led flashes for 2 sec then blinks slowly, getting back to the
program menu
Exit programming menu.
(Same code)
For example;
Let's program code 2345 for user number 5.
Enter program mode by **1234** .Press the following keys in sequence.
1, 05# , 2345# ,2345# ,#
Erasing The User Code(program number 1):
Step DATA entered Description
1
2
3
4
5
6
* *Main code * *
1
Sequence number #
#
#
#
Enter program menu. Green LED blinks slowly.
Select program 1 using '1' key (Programming user code).
Led starts blinking fast..
Led flashes for 2sec, then starts blinking fast. Seq. number can be
between 01 and 30.
Led flashes for 2sec then starts blinking fast
Led flashes for 2 sec then blinks slowly, getting back to the
program menu
Exit programming menu.
ACCESS KEYPAD
SK-30 ACCESS KEYPAD
SK-30
4858
Programming
Programming Relay Time (Program Number 2):
Relay time can be programmed between 01 and 98
If relay time is set as 99 ON/OFF mode is selected. When this mode is selected, entering the code opens the relay lock if it
is closed and vice versa. If magnetic contact will be operated in ON/OFF mode, 12 VAC voltage should be applied to the
lock.
Step DATA entered Description
1
2
3
4
* *Main code * *
2
Time #
#
Enter programming menu. Green LED flashes slowly.
Pressing '2' key, enter Relay time programming.
Led starts blinking fast.
Time; can be between 01 98sec. IF time data is set as 99, then this
is ON/OFF mode. Led blinks slowly, getting back to program menu.
~
Led flashes for 2sec then starts blinking fast
Example;
NOTICE
If desired relay time is 45 sec, enter program menu using 1234 ,press the
following keys in sequence : 2, 45#, #
: for 5 seconds, it should be entered as 05 in time section.
Programming Panic (Program Number 3):
To generate silent alarm # and keys are pressed simultaneously. As a result of this operation, panic output is activated
according to the mode which was programmed before. Panic mode can be programmed in 3 different ways.
1-Panic output is active until user code is entered.
2-Panic output is active for 1 secretary..
3-Panic output is active until key is pressed.
Step DATA entered Description
1
2
3
4
* *Main code * *
3
Panic Mode #
#
Enter programming menu. Green LED flashes slowly.
Panic Mode programming is selected. Led blinks fast.
Mode; can be 1,2 or 3 r.
If Mod=1 then ;Panic output is active until user code is entered.
Mod= 2 ;Panic output is active for 1sec.
Mod= 3; until key is pressed Panic output is active.
Led blinks slowly, getting back to program menu.
Led flashes for 2sec then starts blinking fast
For example;
Let’s programme panic output is active for 1sec
Enter program mode by **1234** .Press the following keys in sequence.
3, 2# ,#
(1,2 or 3)
Popular IP Access Controllers manuals by other brands

Mantra
Mantra Mensa mTerminal100 instruction manual

Intelligent Building Solutions
Intelligent Building Solutions CAP 2020 DR H installation manual

ACT
ACT ACTPRO 4000 Operating and installation instructions

CDVI
CDVI KCPROXWLC installation manual

Belco Security
Belco Security DA3000 user manual

Videx
Videx VX8901F manual