EF FR-DEVIRA User manual

Visitusat:www.friggeri.com
USERMANUAL

GERMICIDALPORTABLELAMP
MODEL:FR‐DEVIRA
Pleasereadcarefullythismanualbeforeusingtheproductandkeepitcarefullyforthefutureuse.
ThesterilizingpowerofUV‐Crays.
Germicidalultravioletradiation,inEnglish"Ultravioletgermicidalirradiation"(UVGI),isasterilization
methodthatusesultraviolet(UV)lightattheUV‐Cwavelength,whichmodifiestheDNAorRNAof
microorganismsandthereforepreventsthemfromreproducingorbeingharmful.
Theamountofradiationneededtodestroyamicroorganismdependsonthetypeofmicroorganismand
environmentalconditions.
ThelethaldoseofUVradiationforamicroorganismthereforedependsonthetimeofexposureandother
factorssuchastemperature,humidityandtheformofreflectionoftherays.
Ourproducthasbeendesignedandconstructedinsuchawayastomaximizetheeffectofradiationand
ensureanoptimalresultinvarioususes.
TheultravioletdoseistheproductoftheUVintensity(expressedasenergyperunitarea)withthe
residencetime:DOSE=IxT(expressedas1mJ/cm2=1000microWattssecond/cm2)
Fromthereport,adoublingoftheapplieddoseincreasesthedestructionbyafactorof10.
Thereforedoublingthedoserequiredforthedestructionof90%youwillhavea99%destruction
ofthetargetorganism.
Triplingthedosewilldestroy99.9%ofthetargetorganismandsoon.
SpeciesDose(mJ/cm2)
Bacillussubtilis(spore)12.0
Clostridiumtetani4.9
LegionellaPneumophilla2.04
Pseudonomasaeruginosa5.5
Streptococcusfeacalis4.5
HepatitisAvirus11.0
HepatitisPoliovirus12.0
Saccharomycescervisiae6.0
Infectiouspancreaticnecrosis 60.0

1Important
Riskinformation:allpersonnelusingUVradiationmustbeinformedoftherisksassociatedwithuse.
Exposurelimitation:theoperatormustkeephimselfasshelteredaspossiblefromthesourceinoperation.
Individualprotection:inthesecasestheprotectivemeasuresrequirecoverageoftheexposedpartsbythe
followingmeans:
faceandeyes:glasses,blinkersorplasticvisor;
handsandarms:glovesandsleeves;
forlongexposuresplasticispreferabletorubber;materialsthattransmitlittleUVarealsopolypropylene
andflannel;
DonotexposeyoureyestotheemittedUVradiation:
Anunprotectedexposureoftheeyescancauseshort‐termreactionssuchasphotosensitivity,
irritationandtransientredness(conjunctivitis,burnsofthecornea,strongtearing,photokeratitis‐
whichisaburnoftheocularsurface);inthelongrun,thedamagecanbeevenmoreserious,
causingcataractsandmaculopathies,reallesionstotheretina.
DonotexposetheskintotheemittedUVradiation:
Intheskin,itoccursintheshorttermerythema;ThelateeffectsofprolongedexposuretoUV
radiationtranslateintoprematureagingoftheskinandtheformationofprecancerousepidermal
cells.
DonotexposeplantsandanimalstotheemittedUVradiation
DonotapplyUVradiationtofabrics,expensivepaintingsorothervaluablestopreventoxidation
duetoprolongedexposuretoultravioletrays.
Donotimmersetheproductinliquids
Donotusetheproductnearhotsourcessuchasradiators,stovesorotherequipmentthat
distributesheat
Thebatterycontainedinitifexposedexcessivelytoheatsuchasdirectsunlight,firecouldexplode
orcausefire
Theappliancemustnotbeexposedtodrippingorsplashing
Donotplaceanysourceofdangerontheappliance(forexampleobjectsfilledwithliquid,orlit
suchascandles,lanterns,etc.).
Keepoutofreachofchildren.
Donotusetheproductwithouthavingpreviouslyreadthisusermanual.

2YourportablegermicidalLEDlamp
Congratulationsonyournewpurchase,youcanfullyenjoyallthebenefitsofyournewpurchaseby
followingtheinstructionsinthismanual.
Introduction
WithFR‐DEVIRA,nowyouwillbeabletoeliminateupto99%ofbacteria,viruses,germs,moldfungiand
allergensfromanysurface.
Insidethebox
Thispackagecontains:
One“DEVIRA”UVlamp
OnechargingUSBcable(adapterNOTincluded)
Oneuseandmaintenancemanual
Constructiondetailsandtopology
1. RedLEDoperatingindicator
2. Suspensionhook
3. BeattheUV‐CLEDlightsource
4. On/offbutton
5. ChargingconnectorandchargingstatusLED
6. Magneticbaseforfixingoninclinablemetal
1
2
3
4
5
6

3Let’sstart
Followtheinstructionsbelowforacorrectrecharge.
Note
Thelampisenergizedbyaninternalrechargeablelithiumionbattery
ThemicroUSBsocketisintendedONLYforchargingthecontainedbattery
Fullrechargetimeinabout2‐3hours
Therechargeablebatteryhasalimitednumberofchargecycles.Batterylifeandnumberofcharge
cyclesvarybyuseandsettings
o Liftthechargingprotectionsidedoor
o ConnectthesuppliedUSBcablebetween:
illatoMicro‐USB(piccolo)nellapresadiricaricalateraledellalampadatheMicro‐USBside
(small)inthesidechargingsocketofthelamp
aUSBsocketonacomputeroraUSBpowersupply(onamobilephoneorsimilar)
o Duringthechargingcycle,theredchargestatusLEDlocatedonthesideofthelampwillbeON
o AttheendofthechargingcyclethestatusLEDwillbeGREEN
o Disconnectthecablewhenlampisfullycharged
o Closethesocketsideprotectiondoor
Thenetworkadapter(NOTSUPPLIED)isSTANDARDUSB5Vtype
4SwitchingONtheLEDsourceonandOFF
BypressingthepowerbuttonwillactivateDeviraaccordingtothelogic:
UV‐CLEDbarlightingandredoperatingindicator
Shutdown
etc.
Automaticshutdown:
ifleftON,thelampwillautomaticallyturnOFFafter5minofoperation.
Importantnotes
DIRECTTHELUMINOUSFLOWDOWNWARDBEFOREPRESSINGTHEIGNITIONBUTTON

5Surfacesterilization
Holdthelampcorrectlytohaveafirmcontrol;
directtheUVemissionsidetowardsthesurfacetobetreated;
turnonthelampbypressingbutton(5)once;
scrollalongthesurfaceatadistanceascloseaspossible(themaximumsterilizingeffectoccursata
distanceof1to10cm)inordertoconcentratetheluminousfluxonthesurface;
forcorrectsterilizationrepeatthepassageoveritrepeatedlyinordertooptimizetheuntreatedspaces;
makesuretoremainonthesinglesurfaceforasufficienttimetoobtainanappreciableresult;
theshadedareasarenotsterilized,somakesureduringtheexposuretoevenlyirradiateallthedesired
surfaces;
UVradiationisnotpenetrating,socleanthesurfacetobetreatedbeforehandbyremovingdust,liquids,
greaseordirtingeneral.
Importantnotes
TURNTHELAMPOFFBEFOREPLACINGIT‐ABSOLUTELYDONOTLEAVEITON
UNIVOCATEDIRECTLYTHELIGHTFLOWTOTHESURFACETOBETREATED
DONOTDIRECTTHELUMINOUSFLOWTOTHEEPIDERMISOREYES
DONOTDIRECTTHEFLOWTOANIMALSOROTHERPEOPLE
Importantnotes
PAYSPECIALATTENTIONTOREFLECTIVE
Importantnotes
Reflectivesurfaces(mirrors,shinyorchromedsurfaces,glass,screens,etc.)couldreflecttheUVflow
towardsyourselforthirdparties.
Itisrecommendedtohandlethelampwithcareduringuseandmakesurenottoharmthirdpartiesduring
use.
Importantnotes
ElettroapparecchiatureFriggerisrlDOESNOTRESPONDfortheproductimproperuse

6Productinformations
Notes
Productfeaturesaresubjecttochangewithoutnoticefromthemanufacturer
Battery
Type Lithiumion
Voltage 3.7V
Capacity 2000mAh
Richarge
Connector U‐usb
Necessarytime 2‐3H
UV‐Csource
SourceLED
Quantity 7
Overallpower 4.2W
Lightwavelenght 260~280nm
Classification UV‐C
Emission H35°‐V52°
WorkingindicatorLEDsource
Type 2x5mmLEDRed
Overallpower 0.2W
Indicativeworkingtime
Normaluse 2,5‐3hours
Intensiveuse 2‐2,5hours
Note
Theautonomieslistedareindicative

7Troubleshooting
Attention
Donodisassemblethelampbodyinordernottovoidthewarranty
Tokeepthewarrantyvalid,nevertrytorepairthelampyourself.
Ifyoufindproblemswhileusingthisdevice,checkthefollowingpointsbeforerequestingassistance.
Iftheproblempersist,consulttheFriggeriwebpage(www.friggeri.com/contattaci).
WhencontactingFriggeri,makesurethatthedeviceisnearby,thedevicemodelnumberandoriginal
packageareavailable.
Noworkingsigns
Chargethelamp
Besurethatchargeriscorrect(standardUSB5V)andworking
Replacethecharger
Verifyiftheconnectioniscorrect
NobrightUVemittedlight
TheUV‐Cradiationishardtobeidentifiedbyeyes
Makesureyouhavepressedthepowerbuttoncorrectly
Makesurethebatteryischared(seepoint3)
8Notice
Anychangesormodificationsmadetothisdevicethatarenotexpresslyapprovedby
ElettroapparecchiatureFriggerimayvoidtheuser'sauthorizationtousetheappliance.
Conformity
ElettroapparecchiatureFriggerisrldeclaresthattheproductcomplieswiththeessentialrequirementsand
otherrelevantprovisionsofDirective89/656/EEC.

Environmentalprotection
Disposaloftheproductwhenusedandthebatterycontained
ThisproductisdesignedandmanufacturedwithqualitymaterialsthatcanberecycledandreusedThis
symbolindicatesthattheproductissubjecttodirective2012/19/EUThissymbolindicatesthatthe
productcontainsanintegratedrechargeablebattery,thedisposalisregulatedbytheEuropeanDirective
2013/56/EUandcannotbedisposedofwithnormaldomesticwaste.Werecommendthatyoucontactan
authorizedcentertoremovetheintegratedbatterybeforedisposal.Findoutaboutthelocalseparate
collectionsystemforelectricalandelectronicproductsandrechargeablebatteries.Followlocalregulations
andneverdisposeoftheproductandrechargeablebatterieswithnormalhouseholdwaste.Properdisposal
ofoldproductsandrechargeablebatterieshelpspreventnegativeconsequencesfortheenvironmentand
humanhealth.
Table of contents
Popular Laboratory Equipment manuals by other brands

Specac
Specac ARROW Quick start manual

HAVER & BOECKER
HAVER & BOECKER HAVER-UWL 400 operating instructions

Swan Analytical Instruments
Swan Analytical Instruments AMI SAC254 Operator's manual

Applied Biosystems
Applied Biosystems GeneAmp PCR System 9700 user guide

Keysight
Keysight M9383A Startup guide

HunterLab
HunterLab EasyMatch QC user manual