Diagnostic Operation
• LED ON = Normal operation of AC protection
• LED OFF = Fault, check AC line voltage and it’s circuit breakers. If all
correct, replace unit. (see Figure 3)
NOTE: The total current rating of the protected equipment should be equal
to or less than the current rating of the DPF shown in the Table 1.
5. Connect copier to DPF.
120 VAC DPF
a. Insert the copier’s AC plug through the tamper proof strip on the
DPF. (see Figure 2a)
b. Plug the copier’s AC plug into the DPF’s Isolated/Filtered Outlet.
(see Figure 2b)
c. Wrap the tamper proof strip and the AC cord with the tape
provided. (see Figure 2b) NOTE: The ServiceTracker Contract (if
applicable) is void if the tape is removed.
208 VAC DPF
a. Plug the copier’s AC plug into the DPF’s Outlet. (see Figure 2c)
6. Plug the DPF’s power cord into an AC wall socket of proper rating
(i.e. 15 AMP or 20 AMP per Table 1).
7. The green diagnostic light should come on indicating AC line
protection is operating properly. (see Figure 3)
Table 1
Model Tel/Network Protection Voltage Current AC Outlets
DPF12015 (R) No 120 VAC 15 A 4
DPF12020 (R) No 120 VAC 20 A 3
DPF12015N (R) Yes 120 VAC 15 A 4
DPF12020N (R) Yes 120 VAC 20 A 3
DPF20815 (R) No 208 VAC 15 A 1
DPF20820 (R) No 208 VAC 20 A 1
DPF20815N (R) Yes 208 VAC 15 A 1
DPF20820N (R) Yes 208 VAC 20 A 1
(R) = ServiceTracker Warranty