SAFETY REQUIREMENTS
• Please read the user’s manual carefully prior to installing and operating the unit.
• All user’s manual requirements as well as the provisions of all the applicable local and national construction, electrical, and technical
norms and standards must be observed when installing and operating the unit.
• The warnings contained in the user’s manual must be considered most seriously since they contain vital personal safety information.
• Failure to follow the rules and safety precautions noted in this user’s manual may result in an injury or unit damage.
• After a careful reading of the manual, keep it for the entire service life of the unit.
• While transferring the unit control, the user’s manual must be turned over to the receiving operator.
CONTENTS
UNIT INSTALLATION AND OPERATION SAFETY PRECAUTIONS
• Disconnect the unit from power mains prior
to any installation operations. • Unpack the unit with care.
• The unit must be grounded!
• While installing the unit, follow the safety
regulations specific to the use of electric
tools.
Safety requirements..................................................................................................................................................................... 2
Purpose................................................................................................................................................................................................ 4
Delivery set........................................................................................................................................................................................ 4
Designation key.............................................................................................................................................................................. 4
Technical data.................................................................................................................................................................................. 5
Design and operating principle ........................................................................................................................................... 7
Installation and set-up................................................................................................................................................................ 7
Connection to power mains .................................................................................................................................................. 8
Technical maintenance.............................................................................................................................................................. 9
Storage and transportation regulations.......................................................................................................................... 9
Manufacturer’s warranty........................................................................................................................................................... 10
Certificate of acceptance.......................................................................................................................................................... 11
Seller information.......................................................................................................................................................................... 11
Installation certificate.................................................................................................................................................................. 11
Warranty card................................................................................................................................................................................... 11
This user’s manual is a main operating document intended for technical, maintenance, and operating staff.
The manual contains information about purpose, technical details, operating principle, design, and installation of the Clean Box(-I) unit
and all its modifications.
Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to
work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country.

3
www.blaubergventilatoren.de
Clean Box(-I)
• Do not change the power cable length at
your own discretion. Do not bend the power
cable. Avoid damaging the power cable. Do
not put any foreign objects on the power
cable.
• Do not lay the power cable of the unit in
close proximity to heating equipment.
• Do not use damaged equipment or cables
when connecting the unit to power mains.
• Do not operate the unit outside the
temperature range stated in the user’s
manual. Do not operate the unit in
aggressive or explosive environments.
• Do not touch the unit controls with wet
hands. Do not carry out the installation and
maintenance operations with wet hands.
• Do not wash the unit with water. Protect the
electric parts of the unit against ingress of
water.
• Do not allow children to operate the unit. • Disconnect the unit from power mains prior
to any technical maintenance.
• Do not store any explosive or highly
flammable substances in close proximity to
the unit.
• When the unit generates unusual sounds,
odour, or emits smoke, disconnect it from
power supply and contact the Seller.
• Do not open the unit during operation. • Do not direct the air flow produced by the
unit towards open flame or ignition sources.
• Do not block the air duct when the unit is
switched on.
• In case of continuous operation of the unit,
periodically check the security of mounting.
• Do not sit on the unit and avoid placing
foreign objects on it. • Use the unit only for its intended purpose.
THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.
DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC WASTE.

4
www.blaubergventilatoren.de Clean Box(-I)
DELIVERY SET
PURPOSE
THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED
PHYSICAL, MENTAL, OR SENSORY CAPACITIES, OR THOSE WITHOUT
THE APPROPRIATE TRAINING.
THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED
PERSONNEL AFTER THE APPROPRIATE BRIEFING.
THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIZED
ACCESS BY UNATTENDED CHILDREN.
The unit is a device for purification of air circulating in ventilation systems.
The unit is a component part and is not designed for stand-alone operation.
The unit is intended for use in supply and recirculation ventilation systems for the purification of air in private homes, offices, hotels,
cafés, conference halls and other utility and public spaces.
The unit is intended for suspended mounting.
Transported air must not contain any flammable or explosive mixtures, evaporation of chemicals, sticky substances, fibrous materials,
coarse dust, soot and oil particles or environments favourable for the formation of hazardous substances (toxic substances, dust,
pathogenic germs).
Name Number
Filter-box 1 pc.
User’s manual 1 pc.
Packing box 1 pc.
DESIGNATION KEY
Clean Box(-I) 100 G4
Filters
G4 – filter of G4 filtration class
F8 – filter of F8 filtration class
H13 – filter of H13 filtration class
C – carbon filter
ES – electrostatic filter
Connected air duct diameter [mm]
100/125/150/200
Unit series
Clean Box: Filter box with panel filters for round air ducts
Clean Box-I: ilter box with panel filters for round air ducts with heat insulation

5
www.blaubergventilatoren.de
Clean Box(-I)
TECHNICAL DATA
The unit is designed for operation in an enclosed area at ambient temperatures from -25 ˚C to + +55 ˚C at relative humidity of up to
80 % (at +25 ˚C).
Ingress protection rating against access to hazardous parts and water ingress is IPX4.
The unit casing is made of painted steel.
The unit design is constantly being improved, thus some models may be slightly different from those described in this manual.
Technical data
Clean Box 100 ES Clean Box 150 ES Clean Box 200 ES
Power supply voltage 50/60 [Hz] 1~110-220
Current consumption [А] 0,1
Power [W] 18
Name Filter type Filter size (HxWxT) [mm]
G3 G4 F8 H13 Carbon
Clean Box(-I) 100 G4-F8 G4/F8 220х400х47 220х400х47 - -
Clean Box(-I) 100 G4-F8-C G4/F8/Carbon 220х400х47 220х400х47 - 220х400х47
Clean Box(-I) 100 G4-H13 G4/H13 220х400х47 - 220х400х47 -
Clean Box(-I) 100 G4-H13-C G4/H13/Carbon 220х400х47 - 220х400х47 220х400х47
Clean Box 100 ES G3/ES 403x216x20 - - - -
Clean Box(-I) 125 G4-F8 G4/F8 220х400х47 220х400х47 - -
Clean Box(-I) 125 G4-F8-C G4/F8/Carbon 220х400х47 220х400х47 - 220х400х47
Clean Box(-I) 125 G4-H13 G4/H13 220х400х47 - 220х400х47 -
Clean Box(-I) 125 G4-H13-C G4/H13/Carbon 220х400х47 - 220х400х47 220х400х47
Clean Box(-I) 150 G4-F8 G4/F8 270х425х47 270х425х47 - -
Clean Box(-I) 150 G4-F8-C G4/F8/Carbon 270х425х47 270х425х47 - 270х425х47
Clean Box(-I) 150 G4-H13 G4/H13 270х425х47 - 270х425х47 -
Clean Box(-I) 150 G4-H13-C G4/H13/Carbon 270х425х47 - 270х425х47 270х425х47
Clean Box 150 ES G3/ES 403х248х20 - - - -
Clean Box(-I) 200 G4-F8 G4/F8 270х590х47 270х590х47 - -
Cleanbox(-I) 200 G4-F8-C G4/F8/Carbon 270х590х47 270х590х47 - 270х590х47
Clean Box(-I) 200 G4-H13 G4/H13 270х590х47 - 270х590х47 -
Clean Box(-I) 200 G4-H13-C G4/H13/Carbon 270х590х47 - 270х590х47 270х590х47
Clean Box 200 ES G3/ES 603х252х20 - - - -

6
www.blaubergventilatoren.de Clean Box(-I)
Overall dimensions of the unit [mm]
D
B
B2
L2
L
L1
H
B1
12
R6
Model D L H B L1 B1 L2 B2
Clean Box(-I) 100 G4-F8 100 413.5 249 415 513.5 508 358.5 458
Clean Box(-I) 100 G4-F8-C 100 413.5 249 415 513.5 508 358.5 458
Clean Box(-I) 100 G4-H13 100 413.5 249 415 513.5 508 358.5 458
Clean Box(-I) 100 G4-H13-C 100 413.5 249 415 513.5 508 358.5 458
Clean Box 100 ES 100 513.5 250 458 613.5 551 456 502
Clean Box(-I) 125 G4-F8 125 413.5 249 415 513.5 508 358.5 458
Clean Box(-I) 125 G4-F8-C 125 413.5 249 415 513.5 508 358.5 458
Clean Box(-I) 125 G4-H13 125 413.5 249 415 513.5 508 358.5 458
Clean Box(-I) 125 G4-H13-C 125 413.5 249 415 513.5 508 358.5 458
Clean Box(-I) 150 G4-F8 150 413.5 299 440 513.5 533 358.5 483
Clean Box(-I) 150 G4-F8-C 150 413.5 299 440 513.5 533 358.5 483
Clean Box(-I) 150 G4-H13 150 413.5 299 440 513.5 533 358.5 483
Clean Box(-I) 150 G4-H13-C 150 413.5 299 440 513.5 533 358.5 483
Clean Box 150 ES 150 513.5 300 458 613.5 551 456 502
Clean Box(-I) 200 G4-F8 200 413.5 299 605 513.5 698 358.5 648
Cleanbox(-I) 200 G4-F8-C 200 413.5 299 605 513.5 698 358.5 648
Clean Box(-I) 200 G4-H13 200 413.5 299 605 513.5 698 358.5 648
Clean Box(-I) 200 G4-H13-C 200 413.5 299 605 513.5 698 358.5 648
Clean Box 200 ES 200 513.5 300 658 613.5 751 456 702

7
www.blaubergventilatoren.de
Clean Box(-I)
DESIGN AND OPERATING PRINCIPLE
The unit is a box with filters of different filter class installed in it.
Each unit involves installation of up to three filters with different supply air filter classes (from coarse to more fine cleaning).
The air flow direction is indicated by the arrow on the fan casing.
INSTALLATION AND SETUP
The unit is suspended to the mounting surface through the threaded rod fixed inside the expansion anchor.
While installing the unit, ensure convenient access for subsequent maintenance and repair.
Fasteners for ceiling mounting are not included into delivery set and should be ordered separately.
While choosing fasteners, consider the material of the mounting surface as well as the weigh of the unit, refer to the Technical data
section.
Fasteners for unit mounting should be selected by the service technician.
min А mm
Nut
Washer
Vibration absorbing
rubber
Washer
Nut and lock nut
min 10 mm
Service side
To get the best performance of the ventilation system and to minimize turbulence-induced air pressure losses, connect the straight air
duct section to the spigots on both sides of the unit while installing.
Minimum straight air duct length:
equal to 1 air duct diameter on intake side
equal to 3 air duct diameters on outlet side
READ THE USER'S MANUAL BEFORE INSTALLING THE UNIT.
Clean Box(-I) ... G4-F8(H13)-C Clean Box ... ES
G3
ES
G4
Carbon
F8(H13)
Air intake
Air exhaust Air intake
Air exhaust

8
www.blaubergventilatoren.de Clean Box(-I)
CONNECTION TO POWER MAINS
POWER OFF THE POWER SUPPLY PRIOR TO ANY OPERATIONS WITH THE UNIT.
THE UNIT MUST BE CONNECTED TO POWER SUPPLY BY A QUALIFIED ELECTRICIAN.
THE RATED ELECTRICAL PARAMETERS OF THE UNIT ARE GIVEN ON THE
MANUFACTURER’S LABEL.
ANY TAMPERING WITH THE INTERNAL CONNECTIONS IS PROHIBITED
AND WILL VOID THE WARRANTY.
The unit is rated for connection to single-phase AC 1~110-220 V 50/60 Hz power mains.
The connection must be made using durable, insulated and heat-resistant conductors (cables, wires).
The unit connections shall be made on the terminal block mounted inside the terminal box in strict accordance with the wiring diagram
and terminal designations.
PE N LF L
Х1
Х2
WIRING DIAGRAM FB-K2 ... ES

9
www.blaubergventilatoren.de
Clean Box(-I)
STORAGE AND TRANSPORTATION REGULATIONS
• Store the unit in the manufacturer’s original packaging box in a dry closed ventilated premise with temperature range
from +5 °C to + 40 °C and relative humidity up to 70 %.
• Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion, insulation, and sealing
deformation.
• Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit.
• Follow the handling requirements applicable for the particular type of cargo.
• The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and
mechanical damage. The unit must be transported only in the working position.
• Avoid sharp blows, scratches, or rough handling during loading and unloading.
• Prior to the initial power-up after transportation at low temperatures, allow the unit to warm up at operating temperature for at least
3-4 hours.
DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE
ANY MAINTENANCE OPERATIONS!
TECHNICAL MAINTENANCE
Maintenance operations of the unit are required 3-4 times per year. Technical maintenance includes regular cleaning of the unit and
periodic cleaning of filters. Dirty filters increase air resistance. The filters require cleaning not less than 3-4 times per year. Vacuum
cleaning is allowed. After two consecutive cleanings filters must be replaced.
For new filters contact the Seller.
Filter replacement sequence:
1. Unscrew the two screws with the plastic head holding the service panel.
2. Open the service panel.
3. Pull the filters to remove.
4. Re-assemble the unit in the reverse order.
The technical maintenance of the electrostatic filter includes periodic cleaning of the surfaces from accumulated dust and dirt.
Clean the electrostatic filter with a soft brush or a vacuum cleaner.
Clean the filter with care. Avoid water ingress to electrical components.

10
www.blaubergventilatoren.de Clean Box(-I)
MANUFACTURER’S WARRANTY
The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby
declare that the product complies with the provisions of Electromagnetic Council Directive 2014/30/EU, Low Voltage Directive 2014/35/
EU and CE-marking Directive 93/68/EEC. This certificate is issued following test carried out on samples of the product referred to above.
The manufacturer hereby warrants normal operation of the unit for 24 months after the retail sale date provided the user's observance
of the transportation, storage, installation, and operation regulations. Should any malfunctions occur in the course of the unit operation
through the Manufacturer's fault during the guaranteed period of operation, the user is entitled to get all the faults eliminated by the
manufacturer by means of warranty repair at the factory free of charge. The warranty repair includes work specific to elimination of faults
in the unit operation to ensure its intended use by the user within the guaranteed period of operation. The faults are eliminated by means
of replacement or repair of the unit components or a specific part of such unit component.
The warranty repair does not include:
• routine technical maintenance
• unit installation/dismantling
• unit setup
To benefit from warranty repair, the user must provide the unit, the user's manual with the purchase date stamp, and the payment
paperwork certifying the purchase. The unit model must comply with the one stated in the user’s manual. Contact the Seller for warranty
service.
The manufacturer’s warranty does not apply to the following cases:
• User’s failure to submit the unit with the entire delivery package as stated in the user’s manual including submission with missing
component parts previously dismounted by the user.
• Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user's manual.
• User’s failure to ensure timely technical maintenance of the unit.
• External damage to the unit casing (excluding external modifications as required for installation) and internal components caused by
the user.
• Redesign or engineering changes to the unit.
• Replacement and use of any assemblies, parts and components not approved by the manufacturer.
• Unit misuse.
• Violation of the unit installation regulations by the user.
• Violation of the unit control regulations by the user.
• Unit connection to power mains with a voltage different from the one stated in the user's manual.
• Unit breakdown due to voltage surges in power mains.
• Discretionary repair of the unit by the user.
• Unit repair by any persons without the manufacturer’s authorization.
• Expiration of the unit warranty period.
• Violation of the unit transportation regulations by the user.
• Violation of the unit storage regulations by the user.
• Wrongful actions against the unit committed by third parties.
• Unit breakdown due to circumstances of insuperable force (fire, flood, earthquake, war, hostilities of any kind, blockades).
• Missing seals if provided by the user’s manual.
• Failure to submit the user’s manual with the unit purchase date stamp.
• Missing payment paperwork certifying the unit purchase.
FOLLOWING THE REGULATIONS STIPULATED HEREIN WILL ENSURE A LONG AND
TROUBLEFREE OPERATION OF THE UNIT.
USER’S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON PRESENTATION
OF THE UNIT, THE PAYMENT DOCUMENT AND THE USER’S MANUAL WITH THE
PURCHASE DATE STAMP.

11
www.blaubergventilatoren.de
Clean Box(-I)
Unit Type Filter box with panel filters for round air ducts
Seller’s Stamp
Model Clean Box _______
Serial Number
Manufacture Date
Purchase Date
Warranty Period
Seller
Unit Type Filter box with panel filters for round air ducts
Model Clean Box _______
Serial Number
Manufacture Date
Quality Inspector’s
Stamp
Seller
Seller’s Stamp
Address
Phone Number
E-mail
Purchase Date
This is to certify acceptance of the complete unit delivery with the user’s manual. The warranty terms are
acknowledged and accepted.
Customer’s Signature
The Clean Box _______ unit is installed pursuant to the requirements stated in the present user's
manual.
Installation Stamp
Company name
Address
Phone Number
Installation
Technician’s Full Name
Installation Date: Signature:
The unit has been installed in accordance with the provisions of all the applicable local and national construction,
electrical and technical codes and standards. The unit operates normally as intended by the manufacturer.
Signature:
CERTIFICATE OF ACCEPTANCE
SELLER INFORMATION
INSTALLATION CERTIFICATE
WARRANTY CARD

www.blaubergventilatoren.de
B185EN-06
This manual suits for next models
7
Table of contents
Other Vents Water Filtration System manuals
Popular Water Filtration System manuals by other brands

Abestorm
Abestorm Filteair HEPA V1 user manual

W&H
W&H Osmo Instructions for use

T.I.P.
T.I.P. TFP 5000 UV 9 Translation of original operating instructions

Grunbeck
Grunbeck desaliQ:BA Series Operation manual

Clean Water Systems
Clean Water Systems Pro-OX 5700-E Installation & start?up guide

BIO UV
BIO UV BIOSUN 340 Installation and maintenance manual