manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Ei Electronics
  6. •
  7. Smoke Alarm
  8. •
  9. Ei Electronics Ei 156TLR Optical User manual

Ei Electronics Ei 156TLR Optical User manual

Model Ei 156TLR Optical
•Remote control capability
•Tamper proof rechargeable lithium battery back up
•High performance optical chamber with integral
insect screen
•Test/Hush button
•Advanced suppression and calibration technology
•Interconnectable to other Ei mains powered alarms
•Built in auto self test feature
•Low power cell warning
•Kitemarked to BS5446-1:2000
•5 year guarantee
Product Description
The Ei156TLR is an Optical Smoke Alarm that runs on
230V AC mains power, and has built in tamper proof
rechargeable lithium cells that act as a battery back up in
the event of mains failure. These rechargeable lithium
cells are designed to have a ten year life and outlast the
life of the smoke alarm itself, whilst providing up to six
months of smoke alarm operation without mains power.
The Ei156TLR allows the detector to be controlled
remotely by either a “Test/Hush” Switch (Ei152), a
“Locate” Switch (Ei159) or a Manual Call Point
(MCP400). If the Ei156TLR is also interconnected to
other Ei mains powered alarms then the whole system
will be controllable remotely.
The Ei156TLR has other advanced features such as
integral insect screens to reduce the chances of false
alarms, as well as the ability to interconnect up to twelve
alarms.
The Ei156TLR has built in circuitry to aid suppression of
voltage transients and RF interference to further reduce
the chances of false alarms under such conditions.
Operation
•The green indicator will illuminate to show mains
power is present
•The red indicator will flash every 40 seconds to
show that the detector has performed an automatic
self test
•The red indicator will flash rapidly to show an alarm
condition for the smoke detector
•The “Test/Hush” button will either silence false
alarms or perform a unit self test
•In “Test” mode the alarm will perform a self test and
sound the horn
•In “Hush” mode the alarm enters a ten minute period
of reduced sensitivity to overcome false alarm
conditions, and will then automatically reset itself
•When interconnected to other Ei mains powered
alarms, an alarm on one detector will trigger all other
interconnected alarms within one second (only the
triggered alarm will flash a red indicator)
•The smoke detector will emit a beep and flash the
red light every 40 seconds to indicate that the
battery back up is depleted and needs recharging
•
MAINS POWERED 230V~
Rechargeable Battery Back-Up
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053
Email. [email protected]
www.eielectronics.com
Model Ei156TLR Optical
Installation & Placement
Wiring for Interconnected Alarms
Be very careful about correctly wiring the alarms as mixing Live and Neutral
will blow/damage interconnected alarms.
Alarms should be placed in accordance with the general guidelines shown in
the diagram above. These recommendations are based on the problem of
areas of “dead air” close to corners of rooms and apexes of ceilings, which
could result in the prevention of smoke reaching the smoke detector
Please consult instruction booklet for specific installation details
Important Precaution:
Do not install the actual smoke/heat
alarm itself in new or renovated
buildings until all work is completed
(including floor coverings) and the
building has been fully cleaned.
The wiring can be installed when
appropriate. (Excessive dust and
debris from building work can
contaminate the smoke chamber
and cause problems, and it will also
invalidate the guarantee). If it must
be installed, cover it completely,
particularly around the edges, with
a dust cover (eg. a plastic bag),
until all cleaning is finished..
Connect wires to the unit as in
wiring diagram. All wiring must
comply with local codes.
Technical Specification
Sensor Optical, uses light scatter from
smoke
Sensitivity: Complies with BS 5446 Part 1:
2000
Source: Contains no radioactive material
Airspeed: Essentially immune to the effect
of airspeed.
Button Test: Simulates the effect of smoke and
checks chamber, electronics and
horn.
Ambient Light: Chamber housing design and
compensation overcomes
problems with stray light.
Automatic Self-Test: Smoke Chamber is tested every 40
Sec. and unit beeps (without LED
flash) if it is degraded.
Insect Screen: Prevents insects or debris entering
chamber (1.00mm mesh size)
Supply Voltage: 230V AC
Battery back up: Rechargeable lithium cells
Power-On Indicator: Continuous green LED
Alarm: Electronic Piezoelectric horn
Alarm Sound Output: 85dB (minimum) at 3m
Alarm Status: Red LED flashes every second on
unit sensing fire
Temperature Range: 0° to 40°C
Humidity Range: 15% to 95% Relative Humidity
Remote Control: Ei152, Ei159 or MCP400
Interconnect: Up to 12 interconnected
Ei150/151TLR/154TL/155/156TLH/
156TLR smoke or heat alarms,
along with an EI158 relay base
Fixing: Screw fixings supplied
Plastic material: UL94VO flame retardant
Dimensions: 140mm x 120mm x 46mm
Weight: 230g
Warranty: 5 year (limited) warranty
Approvals: Kitemarked to BS5446-1:2000, CE
Approved
Specifications are subject to change
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053
Email. [email protected]
www.eielectronics.com

Other Ei Electronics Smoke Alarm manuals

Ei Electronics Ei 105C Optical Manual

Ei Electronics

Ei Electronics Ei 105C Optical Manual

Ei Electronics Easichange Series User manual

Ei Electronics

Ei Electronics Easichange Series User manual

Ei Electronics EiA605MRF User manual

Ei Electronics

Ei Electronics EiA605MRF User manual

Ei Electronics Ei161RC Ionisation User manual

Ei Electronics

Ei Electronics Ei161RC Ionisation User manual

Ei Electronics Ei141 Ionisation User manual

Ei Electronics

Ei Electronics Ei141 Ionisation User manual

Ei Electronics Ei156TLH Optical User manual

Ei Electronics

Ei Electronics Ei156TLH Optical User manual

Ei Electronics Heat Alarm Ei 103R User manual

Ei Electronics

Ei Electronics Heat Alarm Ei 103R User manual

Ei Electronics Ei166R User manual

Ei Electronics

Ei Electronics Ei166R User manual

Ei Electronics Ei140RC Series User manual

Ei Electronics

Ei Electronics Ei140RC Series User manual

Ei Electronics MCP401RC User manual

Ei Electronics

Ei Electronics MCP401RC User manual

Ei Electronics Ei146 Optical User manual

Ei Electronics

Ei Electronics Ei146 Optical User manual

Ei Electronics RadioLINK Ei170RF User manual

Ei Electronics

Ei Electronics RadioLINK Ei170RF User manual

Ei Electronics Ei141EK User manual

Ei Electronics

Ei Electronics Ei141EK User manual

Ei Electronics Ei3100RF? Ei3500RF Manual

Ei Electronics

Ei Electronics Ei3100RF? Ei3500RF Manual

Ei Electronics Ei175 Ionisation User manual

Ei Electronics

Ei Electronics Ei175 Ionisation User manual

Ei Electronics B16009-R0-160RC Series User manual

Ei Electronics

Ei Electronics B16009-R0-160RC Series User manual

Ei Electronics Ei650 Series User manual

Ei Electronics

Ei Electronics Ei650 Series User manual

Ei Electronics Ei146 Optical User manual

Ei Electronics

Ei Electronics Ei146 Optical User manual

Ei Electronics Ei 405C Manual

Ei Electronics

Ei Electronics Ei 405C Manual

Ei Electronics Ei605MTYRF User manual

Ei Electronics

Ei Electronics Ei605MTYRF User manual

Ei Electronics Ei3105RF Optical Manual

Ei Electronics

Ei Electronics Ei3105RF Optical Manual

Ei Electronics Ei 3105TYCH Optical User manual

Ei Electronics

Ei Electronics Ei 3105TYCH Optical User manual

Ei Electronics Ei160 Manual

Ei Electronics

Ei Electronics Ei160 Manual

Ei Electronics Ei161RC Ionisation User manual

Ei Electronics

Ei Electronics Ei161RC Ionisation User manual

Popular Smoke Alarm manuals by other brands

Hochiki SLV Series installation instructions

Hochiki

Hochiki SLV Series installation instructions

First Alert PR710A-6 user manual

First Alert

First Alert PR710A-6 user manual

Kidde PI9010 user manual

Kidde

Kidde PI9010 user manual

EKHO EK-WL8-OV/AU quick start guide

EKHO

EKHO EK-WL8-OV/AU quick start guide

Secutron MR-2320 Series Installation & operation manual

Secutron

Secutron MR-2320 Series Installation & operation manual

Yale EF-SD instruction manual

Yale

Yale EF-SD instruction manual

Vanderbilt WSMK quick start guide

Vanderbilt

Vanderbilt WSMK quick start guide

Weller WFE Series operating instructions

Weller

Weller WFE Series operating instructions

Visonic SMD-426 installation instructions

Visonic

Visonic SMD-426 installation instructions

Notifier AFP-3030 installation manual

Notifier

Notifier AFP-3030 installation manual

Emerald Planet EP-RF-R1 user manual

Emerald Planet

Emerald Planet EP-RF-R1 user manual

Fire Fighting Enterprises Fireray 50 user manual

Fire Fighting Enterprises

Fire Fighting Enterprises Fireray 50 user manual

Kidde 0915CA user manual

Kidde

Kidde 0915CA user manual

Xtralis ICAM IAS-2 Product guide

Xtralis

Xtralis ICAM IAS-2 Product guide

FCI System Sensor 2151 user manual

FCI

FCI System Sensor 2151 user manual

Gentex 7109CS installation instructions

Gentex

Gentex 7109CS installation instructions

Firex FADCP user manual

Firex

Firex FADCP user manual

ETT RM-210RF Reference manual

ETT

ETT RM-210RF Reference manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.