Eiki EZtrol 200L User manual

EZtrol
200L
L
Manual

i
About US
LSE Controls builds products that address the practical problems of
simplified data projector operation. We do this based on our over 30
years of experience in the Audio-Video integration field. We develop
products to solve problems that we face. Because of this we are
committed to designing and building products that are not going to fail
in the field and that are adaptable to a technical environment that
changes at breakneck speed.
We also truly understand the frustration that comes from having a
ten-minute question take two weeks to get answered, that is why we
respond to technical support questions within 24 hours. Our products
are designed to provide affordable, reliable control devices that can
be used as a common look-and-feel system across an organization
for many years.

i
i
Table of Contents
EZtrol 200L Parts List 1
Items Provided by Installer 2
Preloaded Eiki Code 3
Preloaded Timer 4
EZtrol 200L Layout 5
EZtrol 200L Software Installations 6
Programming EZtrol 200L 7-17
Labeling Buttons 18-19
Installing EZtrol 200L 20-24
EZtrol 200L Software Troubleshooting 25
EZtrol 200L Operation Troubleshooting 25

-1-
EZtrol 200L Parts List
• EZtrol 200L
• AC/DC Power Supply
• EZlink Hub
• 2 Screws
• Label Sheet

-2-
Items Provided by Installer
• DB 9 serial cable to connect your computer to EZtrol 200L
• Slotted screw driver
• Hex driver
• 2 pieces of standard Cat 5 cables to run between the EZtrol 200L and EZlink
Hub
• The control cable that comes with the projector or that was purchased from the
projector company
• DB 9 serial cable if connecting the NPC-1

-3-
Preloaded Eiki Code
EZtrol 200L is Preloaded with the RS232 commands for the
Eiki LC-X1100/LC-X986 data projectors
To select the following Eiki data projectors RS232 commands you must
Press button 8 down for 30 seconds. Keep pressing the button down and the
button will blink once then pause for about 3 seconds, then it will blink twice then
pause for 3 seconds. Each set of blinks represents the following drivers for EIKI
model projectors:
LC – X1100 = One Blink
LC – X986 = One Blink
LC – XNB4M = Two Blinks
LC – XNB4 = Two Blinks
LC – NB4 = Two Blinks
LC – NB4S = Two Blinks
LC – NB3EU = Three Blinks
LC – XG200 = Four Blinks
LC – XG100 = Four Blinks
LC – XM4 = Five Blinks
LC – SM4 = Five Blinks
LC – X4A = Six Blinks
LC – X4LA = Six Blinks
LC – X5L = Six Blinks
LC – SX1U = Seven Blinks
LC – SX1UL = Seven Blinks
LC – XT3 = Eight Blinks
L

-4-
Preloaded Timers
EZtrol 200L is preloaded with different timers that can be selected by pressing
button 9 down for 30 seconds. Keep pressing the button down and the button will
blink once then pause for about 3 seconds, then it will blink twice then pause for
3 seconds. Each set of blinks represents a different hour timer.
One hour = One Blink
Two hours = Two Blinks
Three hours = Three Blinks
Four hours = Four Blinks
Five hours = Five Blinks
Six hours = Six Blinks
Seven hours = Seven Blinks
Eight hours = Eight Blinks
Nine hours = Nine Blinks
No timer = Ten Blinks

-5-

-6-
EZtrol 200L software Installation
1. Using your web browser connect to
http://www.eztrol.com/softwareprograms_eztrol200.shtml
2. Then select EZtrol 200 Software from the menu
3. Save the file to your PC
4. Then install the program from your computer’s desktop

-7-
Programming EZtrol 200L
(Best viewed in 1024 x 768 or higher)
1. Connect your EZtrol 200L to your EZlink Hub by taking 2 standard cat 5
cables and places them between EZlink 1 on the hub and EZ 1 on the
control and the second cable to EZlink 2 of the Hub and EZ 2 of the
controller
2. Then take a DB9 female to a DB9 female cable and plug one end into RS-
232-2 and the other into your computer
3. Set the dip switches on the EZlink Hub see page 25
4. Connect the power supply to the EZlink hub .
5. Then choose which level of programming you will need
In this section we will explain the different ways to program the EZtrol 200L
Programming using a Saved file
1. Select EZloader 200L under LSE Controls by clicking on the start menu,
then all programs, then LSE Controls and select EZtrol 200
2. Select File
3. Then Open
4. Select saved file

-8-
Reset Button
Reset Button
5. Select open Note: once file is opened it may be modified for current user specs
6. Select the Upload New Configuration to Control Button
Or
7. The software will prompt you to press the reset button. (reset button is
located on the back of the EZtrol 200L)
8. After the programming status disappears disconnect the cables from the
Computer and press the reset button on the back of the EZtrol 200L and
you are ready for the physical installation of the EZtrol 200L
Standard Programming
1. Select EZtrol 200 under LSE Controls by clicking on the start menu, then
all programs, then LSE Controls and select EZtrol 200
2. Select Projector (from the top of the EZtrol 200 software)
3. Select Model
4. Select Control Port 1

-9-
Reset Button
5. Select Manufacturer
6. Select Model this will provide default codes to the EZtrol 200L
7. Press the Select Button
8. Select the Upload New Configuration to Control Button
Or
9. The software will prompt you to press the reset button. (reset button is
located on the back of the EZtrol 200L)
10. After the programming status disappears, disconnect the cables from the
computer and press the reset button on the back of the EZtrol 200L and
you are ready for the physical installation of the EZtrol 200L

- 10 -
Reset Button
Standard Programming for 2 Devices
1. Same as steps 1 thru 7 in Standard Programming
2. Select Projector (from the top of the EZtrol 200 software)
3. Enable Second Projector
4. Select Projector
5. Select Model
6. Select Control Port 2
7. Select Manufacturer
8. Select Model

- 11 -
Reset Button
Reset Button
9. Press the Select Button
10.Select the Upload New Configuration to Control Button
Or
11.The software will prompt you to press the reset button. (reset button is
located on the back of the EZtrol 200L)
12.After the programming status disappears disconnect the cables from the
computer and press the reset button on the back of the EZtrol 200L and
you are ready for the physical installation of the EZtrol 200L
Standard Programming for a LSE device and a another Device
1. Same as steps 1 thru 7 in Standard Programming
2. Select Control Ports
3. Select Enable LSE Device (this will be on RS232- 2 so you must connect
your other device on RS232-1)
4. Select Upload New Configuration to Control
Or

- 12 -
Reset Button
Reset Button
5. The software will prompt you to press the reset button. (reset button is
located on the back of the EZtrol 200L)
6. After the programming status disappears disconnect the cables from the
Computer and press the reset button on the back of the EZtrol 200L and
you are ready for the Installation of the EZtrol 200L
Advanced Programming
(Changing buttons is not difficult. That said, please bear in mind that calling us for service
after you have modified the code could make you subject to additional charges)
1. Same as steps 1 thru 7 in Standard Programming
2. You now can select what you would like each button to do thru the EZloader
Data base by going to the button and clicking on the drop down arrow and
selecting the new feature for that button.
3. After you are done with each button Select Upload New Configuration to
Control
Or

- 13 -
Reset Button
Reset Button
4. The software will prompt you to press the reset button. (reset button is
located on the back of the EZtrol 200L)
5. After the programming status disappears disconnect the cables from the
computer and press the reset button on the back of the EZtrol 200L and you
are ready for the physical installation of the EZtrol 200L
6. Now you can save the configuration for other installations
Selecting Contact Closure
Use the contact closure feature on the EZtrol 200L by selecting switch relay, and
then pick which button will activate the relay and then select which relay 1 or 2
(you may have multiple buttons select the same relay).
Note: This will setup contacts to momentarily close when button is pushed. Contacts can
be setup to latch. See the custom programming section of this manual to learn more.

- 14 -
Custom Programming
1. Same as steps 1 thru 7 in Standard Programming
2. Type in the custom coding you need for each button by selecting the View
Button Detail/Reconfigure button under each button
3. Then select the configure button
4. Enter in the number of command including start and end commands

- 15 -
Reset Button
Reset Button
5. Enter the RS232 command then select OK
6. Select Upload New Configuration to Control
Or
7. The software will prompt you to press the reset button. (reset button is
located on the back of the EZtrol 200L)
8. After the programming status disappears disconnect the cables from the
computer and press the reset button on the back of the EZtrol 200L and
you are ready for the physical installation of the EZtrol 200L

- 16 -
Timer Programming
This Feature allows you to select a timer that will shut off the devices that are
contacted to the EZtrol for the time you select.
1. Select Timer
2. Select Setup
3. Type in how many hour(s) you need
4. Select OK
5. In this example using a four hour timer the devices that are connected to
the EZtrol 200L will shut down after four hours. The LEDs on the bottom of
the EZtrol 200L are indicators to let you know how much time you have
left before the devices shut down in this example the first LED will shut off
after 1 hour then there will be three remaining lit LEDs which indicate that
you have three hours left, after two hours only two LEDs will remain lit
after three hours only one will remain lit then leaving one hour left before
the devices will shut down. Any time during this process you may select
the ON button to reset the timer and all four LEDs will light up again.

- 17 -
Labeling Buttons
1. Using scissors cut out labels from clear sheet
(Refer to EZloader button layout for placement of label)
2. Remove button cap from EZtrol’s front panel with a thin blade
3. With a thin blade lift the top up of the lens from the diffuser
Diffuser Lens
4. Remove plastic plate that lays in between the lens and the diffuser
Plastic Plate Lens Diffuser
5. Place label between lens and plastic plate. When reassembling make
sure the flat end of the plastic plate faces the lens
Black
Screen
Lens Plastic Plate Diffuser
6. Place Diffuser back into lens and then back onto Controller, repeat until all
10 buttons are identified.
Table of contents
Popular Control Panel manuals by other brands

WAMGROUP
WAMGROUP SEPCOM SIP BED Easy Assembly and main instructions for use and maintenance

BFT
BFT LEO B CBB 3 230 L01 installation manual

Bosch
Bosch D9412GV2 user guide

Honeywell
Honeywell Vigilon 4 loop Generic Commissioning Instructions

MOOSE
MOOSE Z900 quick start guide

ArtiVisuals
ArtiVisuals Mix-iT.ATEM user guide