Elan PVSE User manual

PVSE
INSTALLATION
MANUAL
ELECTRONIC VOLUME CONTROL
PRECISION PANEL
TRIGGERS
12 4356ALL
IR IN
IR OUT
12 4356ALL
12 4356ALL
HOME SYSTEMSTM


ELAN HOME SYSTEMS PVSE INSTALLATION MANUAL
© ELAN Home Systems 2005 • All rights reserved. Page 1
Table of Contents
Introduction ........................................................... 2-3
Features .................................................................3
PVSE Front/Rear Panels .......................................4
Installation ............................................................. 4-6
PF2 Precision Panel Frame .................................. 4
Mounting PVSE to PF2 ......................................... 5
Trim-Out .................................................................6
Connections-ELAN System ............................7-21
ELAN System Overview & Wire Runs .................. 7
Rear Panel Connections ................................... 8-18
RJ-45 Pin Out ........................................................8
Punch-Down Connectors ..................................... 8
VSE 1-6 Connections ............................................9
VSE IR OUTPUTS Connections/PS12 ..................10
VSE IR OUTPUTS Connections/S12 .................... 11
VSE IR OUTPUTS Connections/S6 ...................... 12
VSE IR OUTPUTS Connections/PZ6 ....................13
VSE IR OUTPUTS Connections/Z•630 ................ 14
OVERRIDE IN Connections/PZ600 ...................... 15
OVERRIDE OUT Connections/PZ600 ...................16
OVERRIDE IN Connections/PZ6 .......................... 17
OVERRIDE OUT Connections/PZ6 ...................... 17
IR ROUTING Dipswitch Settings .......................... 18
Front Panel Connections .................................. 19-21
TRIGGERS ............................................................. 19
IR IN ....................................................................... 20
IR OUT ................................................................... 21
Connections-Stand-Alone .............................. 22-27
Stand-Alone Overview & Wire Runs .................... 22
Rear Panel Connections ................................... 23-24
VSE 1-6 Connections ............................................23
IR ROUTING Dipswitch Settings .......................... 24
Front Panel Connections .................................. 25-28
TRIGGERS ............................................................. 25
IR IN ....................................................................... 26
IR OUT ................................................................... 27
Power Supply Connections ........................... 28
Warranty ......................................................Back Page

PVSE INSTALLATION MANUAL ELAN HOME SYSTEMS
Page 2 © ELAN Home Systems 2005 • All rights reserved.
HOME SYSTEMS
TM
2428 Palumbo Dr.
Lexington, KY USA 40509
Voice 859.269.7760
Tech Support 800-622-3526
Introduction
The PVSE Precision Panel makes it easy to connect up to six ELAN
Electronic Volume Controls (VSE, VSE100, and VEHP) to ELAN S
Series and Z•Series equipment, and is also the perfect trim-out
solution for Electronic Volume Controls in any stand-alone system.
The PVSE is one of ELAN’s 1/2 frame Precision Panels and is
designed to be mounted in a PF2 Precision Panel Frame (see
page 4). Two 1/2 frame Precision Panels can be mounted in one
standard-size Precision Panel Frame, giving the flexibility to mix and
match the Precision Panels needed to complete a neat, problem-free
trim-out.
The back of the PVSE features six clearly labeled 110 punchdown
blocks that provide independent connections for Override, IR, and
Sense; plus two additional connectors for easy routing of Electronic
Volume Control IR signals to the System12 Precision Panel (PS12).
Two RJ-45 jacks on the rear of the panel make it easy to route
Override signals from the PZ600 Communications Controller
Precision Panel and link multiple PVSE panels together. There is
also a bank of six dipswitches that allow you to turn the front panel
volume control-specific IR Out ports into ‘ALL’ ports. In stand-alone
applications, this allows all six Electronic Volume Controls to control
any or all sources.
The PVSE’s front panel was designed with stand-alone applications
in mind. Six Trigger Inputs, plus a Trigger ‘ALL’ port, allow you to
mute any or all Electronic Volume Controls whenever voltage is
not present. Six IR Inputs, plus an ‘ALL’ port, allow a VIA!®SR1 or
VIA!®2-SS1 to independently control Electronic Volume Controls
connected to the panel. Six IR Out ports, plus an ‘ALL’ IR Out port,
allow each or all VSEs to control source components in a stand-
alone system.
Electronic Volume Controls that are connected to the PVSE are
powered by the included PWR12 +12VDC/2A power supply.

ELAN HOME SYSTEMS PVSE INSTALLATION MANUAL
© ELAN Home Systems 2005 • All rights reserved. Page 3
Introduction (continued)
Features
• 1/2 Frame Precision Panel for Six ELAN Electronic
Volume Controls (VSE, VSE100, and VEHP)
• 110 Punchdown Connectors w/ Clearly Labeled
Silkscreen for Error-Free Terminations
• Easy to Interface with PS12 and PZ600 Precision Panels
• Multiple PVSEs Can Be Linked Together
• Front Panel Trigger and IR In/Out Jacks
for Stand-Alone Applications
• 12VDC, 2A Power Supply Included
• Fits in PF2 Precision Panel Frame (required for installation)
• Punchdown Tool & Caps Included
PVSE Front/Rear Panels
• TRIGGERS (Inputs)
Connects to Triggering Device
• IR IN
Connects to IR Source
• 12VDC/2A
Connects to PWR12 Power Supply
• IR OUT
Connects to Source to be Controlled
• VSE 1-6
Connects to ELAN Electronic Volume
Controls (VSE, VSE100, VEHP)
• IR ROUTING Dipswitches
Controls IR OUT IR Routing
• VSE IR OUTPUTS
Connects to ELAN Multi-Zone
Controllers
• OVERRIDE OUT
Connects to additional PVSE
• OVERRIDE IN
Connects from a PZ600, Z•600,
or additional PVSE
TRIGGERS
12 4356ALL
IR IN
IR OUT
12 4356ALL
12 4356ALL
SENSEGV+NC NCIROVCO IRI
SENSENC V+ GIROVCO IRI NC
VSE 2 VSE
3
VSE 5 VSE 4
VSE 6
SENSEGV+NCNC
IRI
IROVCOSENSEIROVCO NC
IRI NC V+ VCO NC
IRI
IRO V+NC SENSE
GG IR G
IR
G
IR GGGG
VSE IR
OUTPUTS
OVERRIDE
OUT
OVERRIDE
IN
123
45
GG
IR
6
IR
ALL
123456
IR ROUTING
IR
SENSENC V+ GIROVCO IRI NC
VSE 1
GG
Front
Rear

PVSE INSTALLATION MANUAL ELAN HOME SYSTEMS
Page 4 © ELAN Home Systems 2005 • All rights reserved.
Installation
PF2 Precision Panel Frame
The PF2 accommodates any two 1/2 frame Precision Panels.
The kit includes a full-size Precision Panel frame, an insert with pre-
drilled holes for the mounting of two 1/2 frame Precision Panels,
mounting screws, and a blank 1/2 frame plate to cover an unused
half of the frame. PBKT6P new-construction brackets are available,
or the PF2 can easily be retro-fitted using the four clamping legs
attached to the frame, which clamp the panel securely to drywall.
Note: The PF2 is required for the installation of all 1/2 frame
Precision Panels.

ELAN HOME SYSTEMS PVSE INSTALLATION MANUAL
© ELAN Home Systems 2005 • All rights reserved. Page 5
Installation (continued)
Mounting the PVSE to the PF2
Each 1/2 frame Precision Panel mounts from the back of the PF2.
Use four included screws inserted from the front of the PF2 as
shown below.
Screw
Screw
Screw
Screw
PF2 Front
Front
TRIGGERS
12 4356ALL
IR IN
IR OUT
12 4356ALL
12 4356ALL

PVSE INSTALLATION MANUAL ELAN HOME SYSTEMS
Page 6 © ELAN Home Systems 2005 • All rights reserved.
Installation (continued)
Trim-Out
All system wire runs are pulled through the PF2 frame. Lay the PVSE
front panel (attached to the PF2) on the floor in front of the frame
and make all connections. Dress the wires in neat bundles, being
careful not to pull off any punchdown connections, and then carefully
place the PVSE/PF2 back into the frame and secure using the four
screws.
Wire Runs

ELAN HOME SYSTEMS PVSE INSTALLATION MANUAL
© ELAN Home Systems 2005 • All rights reserved. Page 7
Connections-ELAN System
PVSE ELAN System Overview and Wire Runs
XM FM
123456
+
--
1
ZONE
1
LOCAL
22
ZONE LOCAL
33
ZONE LOCAL
4
ZONE
4
LOCAL
55
ZONE LOCAL
6
ZONE
6
LOCAL
8
LOCAL
8
ZONE
7
LOCAL
7
ZONE VIA!POWER
16VDC / 10A
16VDC / 4A
VIA!NET
TO SENSE INPUTS
USE STEREO 3.5mm PLUGS ONLY
EXTIR ANTENNA
+12VDC
Power
Supply
PS12
PZ600
V
SE/VEHP
PWR12
(included)
TRIGGERS
12 4356ALL
IR IN
IR OUT
12 4356ALL
12 4356ALL
VSE/VEHP VSE/VEHP VSE/VEHP VSE/VEHP VSE/VEHP
To Z•600
To S12
1
1
1
2
1Cat-5
2ELAN C4545 RJ-45 Interconnect Cable

PVSE INSTALLATION MANUAL ELAN HOME SYSTEMS
Page 8 © ELAN Home Systems 2005 • All rights reserved.
ELAN System Connections (continued)
Rear Panel Connections
RJ-45 Pin Out
ELAN recommends using ELAN C4545 and/or C45P RJ-45 intercon-
nect cables for all Cat-5 connections to the PVSE. Should you prefer
to terminate your own RJ45 cables, refer to the diagram below for
the correct pin-out.
PVSE Punch-Down Connectors
The back of the PVSE uses standard 110 punchdown connectors for
all wire runs. Wires do not need to be stripped prior to punchdown
as the insulation will automatically be displaced. Each punchdown
row will accept two 24 or 22 AWG solid conductor wires. Use the
included 110 punchdown tool to properly make connections and
avoid damaging the PVSE.
110 Punch-Down Connecto
r
NOTE:
The PVSE comes with punch-
down caps to ensure that
connections won’t come loose.

ELAN HOME SYSTEMS PVSE INSTALLATION MANUAL
© ELAN Home Systems 2005 • All rights reserved. Page 9
ELAN System Connections-Rear (continued)
VSE 1-6 Connections
Punch-down each wire according to ELAN standard pin-out
(previous page). Be sure to note which Electronic Volume Control
is punched-down to each connector. The diagram below shows
VSE’s #1 through #3 properly connected.
SENSEGV+NC NCIROVCO IRI
SENSENC V+ GIROVCO IRI NC
VSE 2 VSE
3
VSE 5 VSE 4
VSE 6
SENSEGV+NCNC
IRI
IROVCOSENSEIROVCO NC
IRI NC V+ VCO NC
IRI
IRO V+NC SENSE
GG IR G
IR
G
IR GGGG
VSE IR
OUTPUTS
OVERRIDE
OUT
OVERRIDE
IN
123
45
GG
IR
6
IR
ALL
123456
IR ROUTING
IR
SENSENC V+ GIROVCO IRI NC
VSE 1
GG
VSE/VEHP #3
Blue
Wh/Blue
Orange
Wh/Orange
Green
Wh/Green
Brown
Wh/Brown
VSE/VEHP #2
Blue
Wh/Blue
Orange
Wh/Orange
Green
Wh/Green
Brown
Wh/Brown
VSE/VEHP #1
Blue
Wh/Blue
Orange
Wh/Orange
Green
Wh/Green
Brown
Wh/Brown

PVSE INSTALLATION MANUAL ELAN HOME SYSTEMS
Page 10 © ELAN Home Systems 2005 • All rights reserved.
ELAN System Connections-Rear (continued)
VSE IR OUTPUTS Connections to PS12
The VSE IR OUTPUTS are designed to route IR from a specific
Electronic Volume Control to a specific zone of an S6, S12,
or Z•system. When installing an S12 system, ELAN strongly
recommends the use of the PS12 Precision Panel! To route IR to
a specific S12 zone, use a run of Cat-5 to connect IR and Ground
from VSE IR OUTPUTS on the PVSE to ADDITIONAL IR INPUTS
on the PS12. Make sure to connect the correct VSE IR OUTPUT on
the PVSE to the correct ADDITIONAL IR INPUT on the PS12. The
diagram below shows VSE #1 connected to S12 Zone 1.
SENSEGV+NC NCIROVCO IRI
SENSENC V+ GIROVCO IRI NC
VSE 2 VSE3
VSE 5 VSE
6
VSE 4
SENSEGV+NCNC
IRI
IROVCOSENSEIROVCO NC
IRI NC V+ VCO NC
IRI
IRO V+NC SENSE
GG IR G
IR
G
IR GGGG
VSE IR
OUTPUTS
OVERRIDE
OUT
OVERRIDE
IN
123
45
GG
IR
6
IR
ALL
123456
IR ROUTING
IR
PVSE
ADDITIONAL IR INPUTS
IRIR G
1
IR
G
2
G
3
IR G
4
PS12
GG
SENSENC V+ GIROVCO IRI NC
VSE 1

ELAN HOME SYSTEMS PVSE INSTALLATION MANUAL
© ELAN Home Systems 2005 • All rights reserved. Page 11
ELAN System Connections-Rear (continued)
VSE IR OUTPUTS Connections to S12 (no PS12)
If not using a PS12 to install an S12 system, it is necessary to
connect two conductors of a Cat-5 wire from the PVSE’s VSE IR
OUTPUTS to the ZONE KEYPAD INPUTS of the S12. Connect
IR from the PVSE to the Wh/Blue IR Input wire (PIN 2) of the S12.
Connect Gfrom the PVSE to Brown (Pin 7) of the S12. Make these
connections in parallel with any keypads or touch panels that are in
the same zone as the Electronic Volume Control. Make sure to con-
nect the correct VSE IR OUTPUT of the PVSE to the correct ZONE
KEYPAD INPUT of the S12. The diagram below shows VSE #1 to
S12 Zone 1 connections. Only the keypad’s IR and Ground are
shown for clarity.
SENSEGV+NC NCIROVCO IRI
SENSENC V+ GIROVCO IRI NC
VSE 2 VSE3
VSE 5 VSE
6
VSE 4
SENSEGV+NCNC
IRI
IROVCOSENSEIROVCO NC
IRI NC V+ VCO NC
IRI
IRO V+NC SENSE
GG IR G
IR
G
IR GGGG
VSE IR
OUTPUTS
OVERRIDE
OUT
OVERRIDE
IN
123
45
GG
IR
6
IR
ALL
123456
IR ROUTING
IR
PVSE
GG
SENSENC V+ GIROVCO IRI NC
VSE 1
S12
ELAN C45P RJ-45
interconnect cable
White/Blue (IR)
Brown (GND)
Keypad
Brown (GND)
White/Blue (IR)

PVSE INSTALLATION MANUAL ELAN HOME SYSTEMS
Page 12 © ELAN Home Systems 2005 • All rights reserved.
ELAN System Connections-Rear (continued)
VSE IR OUTPUTS Connections to S6
When installing a PVSE into an ELAN S6 system, connect two
conductors of a Cat-5 wire from the VSE IR OUTPUTS to the
ZONE KEYPAD INPUTS of the S6. Connect IR from the PVSE to
the Wh/Blue IR Input wire (PIN 2) of the S6. Connect Gfrom the
PVSE to Brown (Pin 7) of the S6. Make these connections in parallel
with any keypads or touch panels that are in the same zone as the
Electronic Volume Control. Make sure to connect the correct VSE IR
OUTPUT of the PVSE to the correct ZONE KEYPAD INPUT of the
S6. The diagram below shows VSE #1 to S6 Zone 1 connections.
Only the keypad’s IR and Ground are shown for clarity.
SENSEGV+NC NCIROVCO IRI
SENSENC V+ GIROVCO IRI NC
VSE 2 VSE3
VSE 5 VSE
6
VSE 4
SENSEGV+NCNC
IRI
IROVCOSENSEIROVCO NC
IRI NC V+ VCO NC
IRI
IRO V+NC SENSE
GG IR G
IR
G
IR GGGG
VSE IR
OUTPUTS
OVERRIDE
OUT
OVERRIDE
IN
123
45
GG
IR
6
IR
ALL
123456
IR ROUTING
IR
PVSE
GG
SENSENC V+ GIROVCO IRI NC
VSE 1
ELAN C45P RJ-45
interconnect cable
White/Blue (IR)
Brown (GND)
S6
Keypad
Brown (GND)
White/Blue (IR)

ELAN HOME SYSTEMS PVSE INSTALLATION MANUAL
© ELAN Home Systems 2005 • All rights reserved. Page 13
ELAN System Connections-Rear (continued)
VSE IR OUTPUTS Connections to PZ6
When installing an ELAN Z system, the PVSE will route IR from a
specific Electronic Volume Control to a specific Z•system zone.
Panel! To route IR to a specific Z•630 zone, use a run of Cat-5 to
connect IR and Ground from VSE IR OUTPUTS on the PVSE to
ZONE punch-down locations on a PZ6 Precision Panel. Make sure
to connect the correct VSE IR OUTPUT on the PVSE to the correct
ZONE punchdown location on the PZ6. The diagram below shows
VSE #1 to ZONE 1 connections.
SENSEGV+NC NCIROVCO IRI
SENSENC V+ GIROVCO IRI NC
VSE 2 VSE3
VSE 5 VSE
6
VSE 4
SENSEGV+NCNC
IRI
IROVCOSENSEIROVCO NC
IRI NC V+ VCO NC
IRI
IRO V+NC SENSE
GG IR G
IR
G
IR GGGG
VSE IR
OUTPUTS
OVERRIDE
OUT
OVERRIDE
IN
123
45
GG
IR
6
IR
ALL
123456
IR ROUTING
IR
PVSE
GG
SENSENC V+ GIROVCO IRI NC
VSE 1
Br
Wh/G
r
Gr
Wh/O
r
Wh/Bl
nc
Or
Wh/B
r
PZ6

PVSE INSTALLATION MANUAL ELAN HOME SYSTEMS
Page 14 © ELAN Home Systems 2005 • All rights reserved.
ELAN System Connections-Rear (continued)
VSE IR OUTPUTS Connections to Z•630 (no PZ6)
If not using a PZ6 to install a Z• system, it is necessary to connect
two conductors of a Cat-5 wire from the PVSE’s VSE IR OUTPUTS
to the IR INPUTS of the Z•630. Connect IR from the PVSE to the
IR INPUTS wire of the specific zone of the Z•630 that the Electronic
Volume Control will be assigned to . Connect Gfrom the PVSE to
Brown (Pin 7) of the Z•630. Make these connections in parallel with
any keypads or touch panels that are in the same zone as the
Electronic Volume Control. The diagram below shows VSE #1 con-
nected to Zone #2 of a Z•630. Only the keypad’s IR and Ground
connections are shown for clarity. See the Z•630 Installation
Manual for complete details about IR INPUT wiring of a Z• system.
IR
INPUTS
Z•630
SENSEGV+NC NCIROVCO IRI
SENSENC V+ GIROVCO IRI NC
VSE 2 VSE3
VSE 5 VSE
6
VSE 4
SENSEGV+NCNC
IRI
IROVCOSENSEIROVCO NC
IRI NC V+ VCO NC
IRI
IRO V+NC SENSE
GG IR G
IR
G
IR GGGG
VSE IR
OUTPUTS
OVERRIDE
OUT
OVERRIDE
IN
123
45
GG
IR
6
IR
ALL
123456
IR ROUTING
IR
PVSE
GG
SENSENC V+ GIROVCO IRI NC
VSE 1
ELAN C45P RJ-45
interconnect cable
White/Blue (IR)
Brown (GND)
Keypad
Brown (GND)
White/Blue (IR)
Zone 2 Shown

ELAN HOME SYSTEMS PVSE INSTALLATION MANUAL
© ELAN Home Systems 2005 • All rights reserved. Page 15
ELAN System Connections-Rear (continued)
OVERRIDE IN Connections w/ PZ600
The OVERRIDE IN RJ-45 jack is designed to take the Volume
Control Override signal from a Z•600 Communications Controller
and automatically route it to the VC+ and VC- connections on
Electronic Volume Controls connected to the PVSE. Use of a PZ600
Precision Panel is highly recommended when installing a PVSE in an
ELAN S6 or S12 system that includes a Z•600. Connect an ELAN
C4545 RJ-45 patch cable from the Z•600’s CONTROL OUTPUTS
jack to the OVERRIDE IN RJ-45 jack on the PZ600, then connect an
additional C4545 from the PZ600’s OVERRIDE OUT jack to
OVERRIDE IN of the PVSE as shown below.
VCO
COM
N.O.
COM
N.O.
COM
N.O.
COM
N.O.
W/Bl
Br
W/Br
W/Or
W/Gr
Gr
Or
Bl
RELAY DS1
M-
DS+
DS-
L+
L-
DB-
DB+
M+
L+
DS-
DS+
L-
DB-
M-
DB+
M+
DS2
W/Or
W/Br
Br
W/Gr
Gr
W/Bl
Or
Bl
TELCO
RNG
nc
nc
nc
nc
TIP
TIP
RNG
VCO
4321
PHONE
TELCO
OVERRIDE
OUT
VC+
VC-
VC-
VC+
VC+
VC-
VC-
VC+
VC-
VC-
VC+
VC+
VC+
VC-
VC+
VC-
OVERRIDE
IN
PZ600 Rear
ELAN C4545 RJ-45
interconnect cable
SENSEGV+NC NCIROVCO IRI
SENSENC V+ GIROVCO IRI NC
VSE 2
VSE 3
VSE 5
VSE 6 VSE 4
SENSEGV+NCNC
IRI
IROVCOSENSEIROVCO NC
IRI NC V+ VCO NC
IRI
IRO V+NC SENSE
GG IR G
IR
G
IR GGGG
VSE IR
OUTPUTS
OVERRIDE
OUT
OVERRIDE
IN
123
45
GG
IR
6
IR
ALL
123456
IR ROUTING
IR
SENSENC V+ GIROVCO IRI NC
VSE 1
ELAN C4545 RJ-45
interconnect cable
PVSE Rear
G
G

PVSE INSTALLATION MANUAL ELAN HOME SYSTEMS
Page 16 © ELAN Home Systems 2005 • All rights reserved.
ELAN System Connections-Rear (continued)
OVERRIDE OUT Connections w/ PZ600
The OVERRIDE OUT RJ-45 jack is designed for system expansion.
When connecting multiple PVSE’s, connect the OVERRIDE OUT
RJ-45 jack from PVSE #1 to the OVERRIDE IN RJ-45 jack on PVSE
#2. Continue the process for all PVSEs in the system. The diagram
below shows a Z•600 connected to a PZ600, then to two PVSEs.
VCO
COM
N.O.
COM
N.O.
COM
N.O.
COM
N.O.
W/Bl
Br
W/Br
W/Or
W/Gr
Gr
Or
Bl
RELAY DS1
M-
DS+
DS-
L+
L-
DB-
DB+
M+
L+
DS-
DS+
L-
DB-
M-
DB+
M+
DS2
W/Or
W/Br
Br
W/Gr
Gr
W/Bl
Or
Bl
TELCO
RNG
nc
nc
nc
nc
TIP
TIP
RNG
VCO
4321
PHONE
TELCO
OVERRIDE
OUT
VC+
VC-
VC-
VC+
VC+
VC-
VC-
VC+
VC-
VC-
VC+
VC+
VC+
VC-
VC+
VC-
OVERRIDE
IN
PZ600 Rear
ELAN C4545 RJ-45
interconnect cable
SENSEGV+NC NCIROVCO IRI
SENSENC V+ GIROVCO IRI NC
VSE 2
VSE 3
VSE 5
VSE 6 VSE 4
SENSEGV+NCNC
IRI
IROVCOSENSEIROVCO NC
IRI NC V+ VCO NC
IRI
IRO V+NC SENSE
GG IR G
IR
G
IR GGGG
VSE IR
OUTPUTS
OVERRIDE
OUT
OVERRIDE
IN
123
45
GG
IR
6
IR
ALL
123456
IR ROUTING
IR
SENSENC V+ GIROVCO IRI NC
VSE 1
PVSE #1 Rear
G
G
SENSEGV+NC NCIROVCO IRI
SENSENC V+ GIROVCO IRI NC
VSE 2VSE 3
VSE 5
VSE 6 VSE 4
SENSEGV+NCNC
IRI
IROVCOSENSEIROVCO NC
IRI NC V+ VCO NC
IRI
IRO V+NC SENSE
GG IR G
IR
G
IR GGGG
VSE IR
OUTPUTS
OVERRIDE
OUT
OVERRIDE
IN
123
45
GG
IR
6
IR
ALL
123456
IR ROUTING
IR
SENSENC V+ GIROVCO IRI NC
VSE 1
PVSE #2 Rear
G
G
ELAN C4545 RJ-45
interconnect cable
To additional PVSEs

ELAN HOME SYSTEMS PVSE INSTALLATION MANUAL
© ELAN Home Systems 2005 • All rights reserved. Page 17
ELAN System Connections-Rear (continued)
OVERRIDE IN Connections w/ PZ6
If using the PVSE witha PZ6 Precision Panel for Z• Systems, it is
necessary to use an ELAN C45P RJ-45 to pigtail cable to connect
VC+ and VC- from the back of the PZ6 to theOVERRIDE IN RJ-45
jack on the back of the PVSE as shown below. Pin 1 (Blue) of the
RJ-45 cable is VC+, Pin 2 (Wh/Blue) is VC-.
OVERRIDE OUT Connections w/ PZ6
OVERRIDE OUT connections will go to additional PVSEs exactly as
shown on p. 16.
ELAN C45P
RJ-45 to
pigtail cable
OVERRIDE
IN
Blue
Wh/Blue
OVERRIDE
OUT
PZ6
PVSE

PVSE INSTALLATION MANUAL ELAN HOME SYSTEMS
Page 18 © ELAN Home Systems 2005 • All rights reserved.
ELAN System Connections-Rear (continued)
IR ROUTING Dipswitch Settings
IR from Electronic Volume Controls connected to the PVSE can be
routed to the front IR Output jacks in two different ways. By default,
the dipswitches are all down, meaning that each Electronic Volume
Control sends IR to its’ specific IR port on the front of the panel, and
the ALL port. For example, the Electronic Volume Control connected
to the VSE 1 location will only send IR out of IR OUT 1 and ALL.
By moving a dipswitch to the upper ALL position, the corresponding
IR OUT port becomes an ALL port; passing IR signals from every
Electronic Volume Control that is connected to the PVSE.
The original ALL port remains active and functions identically
regardless of dipswitch settings.
In the example below, Dipswitch #1 is in the Up position. IR OUT
#1 will pass IR sent from any Electronic Volume Control that is con-
nected to the PVSE. Dipswitch #2 is in the Down position. IR OUT
#2 will only pass IR from the Electronic Volume Control connected to
the VSE 2 location. The ALL port will pass IR from both volume
controls.
ALL
123456
IR ROUTING
TRIGGERS
12 4356ALL
IR IN
IR OUT
12 4356ALL
12 4356ALL
Emits IR from any
Volume Control
Emits IR from
Volume Control #2
Emits IR from any
Volume Control
Table of contents