Replacing the lamp
DANGER TO LIFE! Only install the lamp with the device switched off! Unplug from mains before!
CAUTION! The lamp has to be replaced when it is damaged or thermally deformed due to the heat!
The lens must be replaced if it is visibly damaged and therefore operating with reduced efficiency.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp
manufacturer’s notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the
device was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need one GY9.5 halogen lamp with up to max. 500W
Procedure:
Step 1:Unscrew the handle screw on the rear of the device.
Step 2: Push out the cover to the back.
Step 3: Remove the old lamp.
Step 4: Insert the same type lamp into the lamp-socket.
Step 5: Replace the cover and screw the handle screw.
Installing
The installation of the device has to be built and constructed
in a way that it can hold 10 times the weight for 1 hour
without any harming deformation.
The installation must always be secured with a secondary
safety attachment, e.g. an appropriate catch net. This
secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the fixture staying in the area below the installation place, on
bridges, under high working places and other endangered areas is forbidden.
The device should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE
EXPERIENCE, including (but not limited to) calculation working
load limits, installation material being used, and periodic safety
inspection of all installation material and the device.
The device has to be installed out of the reach of people.
If the device shall be lowered from the ceiling or high joists,
professional trussing systems have to be used. The device must
never be fixed swinging freely in the room.
Caution: Devices may cause severe injuries when crashing down!
If you have doubts concerning the safety of a possible installation,
do NOT install the device!
DANGER OF FIRE! When installing the device, make sure there is
no highly-inflammable material (decoration articles, etc.) within a
distance of min. 0.5 M.
Mount the device with the mounting-bracket to your trussing system
using an appropriate clamp. The hole in the mounting bracket has a
diameter of 13 mm.
For overhead use, always install a safety-rope that can hold at least
10 times the weight of the fixture. You must only use safety-ropes
with screw-on carabines. Pull the safety-rope through the hole in
the mounting-bracket and over the trussing system etc. Insert the
end in the carabine and tighten the safety screw.
Adjust the desired inclination-angle via the mounting-bracket and fix the fixation screws.
DANGER TO LIFE! Before taking into operation for the first time, the installation has to be approved
by an expert or by qualified ENGINEERS/TECHNICIANS only!
Connection with the mains
DANGER TO LIFE! The electric connection must only be carried out by a qualified electrician!
In order to connect the device to the mains, you have to install a power-plug.
The occupation of the connection-cables is as follows:
Cable Pin International
Brown Live L
Blue Neutral N
Yellow/Green Earth
The earth has to be connected!
Connect the device to the mains with the power-plug.
If the device will be directly connected with the local power supply network, a disconnection switch with
a minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
In general, lighting effects should not be connected to dimming-packs.
DANGER TO LIFE! Before taking into operation for the first time, the installation has to be approved
by an expert!
OPERATION:
After you connected the fixture to the mains, the lamp will be on. You can adjust the beam angle by
pulling and pushing the handle screw through the track beneath the device.
CLEANING AND MAINTENANCE
The following points have to be considered during the inspection:
1)All screws used for installing the devices or parts of the device have to be tightly connected and
must not be corroded.
2)There must not be any deformations on housings, fixations and installation spots(ceiling,
suspension. trussing).
3)The electric power supply cables must not show any damages, material fatigue (e.g. porous cables)
or sediments. Further instructions depending on the installation spot and usage have to be adhered
by a skilled installer and any safety problems have to be removed.
DANGER TO LIFE! Disconnect from mains before starting maintenance operation!
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use
alcohol or solvents!
The interior of the device should be cleaned at least annually using a vacuum-cleaner or an air-jet.
There are no serviceable parts inside the device except for the lamp. Maintenance and service
operations are only to be carried out by authorized dealers.
Please refer to the instructions under “Replacing the lamp”.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers
only in order to avoid hazards.
Should you have further questions, please contact your dealer.
HANDLE
SCREW
COVER
1.TRUSSING
2.SAFETY-ROPE
3.SCREW-ON
CARABINE
4.SAFETY-SCREW
5.HOOK