The ELC dmXLAN node3 has 3 bi-directional DMX ports to convert from or to sACN,
Art-Net or Shownet. An internal switch provides a second Ethernet port for a local
lighting desk or additional Ethernet switches or nodes. The node3 can be outfitted
with fully isolated DMX ports and Power over Ethernet.
The ELC dmXLAN node3 is available in the following variations:
DLN3T truss mount
DLN3T _FI truss mount – fully isolated
DLN3T POE truss mount Power over Ethernet
DLN3T POE_FI truss mount Power over Ethernet – fully isolated
DLN3S surface mount
DLN3S_FI surface mount – fully isolated
DLN3W recessed wall mount
DLN3W_FI recessed wall mount – fully isolated
DLN3DIN DIN version
DLN3DIN_FI DIN version – fully isolated
• 3 Bi-directional DMX ports on the rear panel, XLR, RDM compatible
• Supports sACN, Art-Net & Shownet
• 2 Ethernet ports (Neutrik Ethercon) 10/100MBit with integral Ethernet switch
• Remote programming and monitoring, with remote fixture parameter override
• DMX Input normal or backup
• DMX Output normal, HTP, priority merging, softpatch (channel by channel),
programmable merging with DMX channel control
• Local control via backlit display, rotary encoder/selector pushbutton
• Support for WYSIWYG, ESP, Capture
Features

__________________________________________________________________________________
ELC dmXLAN node3 User Manual
Truss Mount (DLN3T / DLN3T_FI)
The Truss Mount version of the node3 has a built-in power supply and is equipped
with 3 DMX ports and 2 Ethernet ports (both with Neutrik Ethercon) located on the
back of the device. The DMX ports are bi-directional so they can function as input or
output. The unit has an M10 nut on the bottom and a safety eye. The DLN3T is also
available in a fully isolated version (DLN3T_FI). All node3 Truss Mount versions can be
mounted in a 19” rack using the ELC Rack Mount Kit (ELC-RMKIT).
Truss Mount Power over Ethernet (DLN3TPOE / DLN3TPOE_FI)
The Truss Mount Power over Ethernet version of the node3 has specifications
identical to the regular node3 Truss Mount, except for the power supply. This version
is powered by PoE instead of a built-in power supply. The PoE version of the node3
Truss Mount is also available in a fully isolated version (DLN3TPOE_FI).
Surface Mount (DLN3S / DLN3S_FI)
The Surface Mount version of the node3 can be mounted onto a wall.
The Surface Mount unit has 3 bi-directional DMX ports located on the front of the
device. The DMX ports can be ordered in male or female version (any combination is
possible), as well as a version with fully isolated DMX ports (DLN3T_FI). There is also
one Ethernet connection (Neutrik Ethercon) on the front of the node3 SM. Another –
internal – Ethernet connection (RJ45) is located on the back of the device. This is the
main Ethernet input and requires a PoE switch as its power supply. To gain access to
the internal Ethernet connection, a technician must open the housing of the node3
by removing the four screws located along the sides of the front panel.
Wall Mount (DLN3W / DLN3W_FI)
The Wall Mount version features the same hardware and specifications as the
Surface Mount version, but the housing is designed for recessed wall mounting.
DIN Version (DLN3DIN / DLN3DIN_FI)
This DIN-rail mounted Power over Ethernet version connects 3 bi-directional DMX
ports to an Ethernet network, and an internal switch provides a second Ethernet port
for a local lighting desk or a PC running ELC dmXLAN control/management freeware
or additional Ethernet switches or nodes.
The DIN version of the node3 is also available in a fully isolated version (DLN3DIN_FI).
Versions

__________________________________________________________________________________
ELC dmXLAN node3 User Manual
Network 10/100 Mbit Ethernet (on Neutrik Ethercon or RJ-45)
The network connection uses a standard UTP network connection.
DMX port pin out
Pin
Description
1
Ground/screen
2
Data –
3
Data +
4
–
5
–
All DMX ports are bi-directional (can act as input or output) with RDM preparation
and can optionally be supplied in a fully isolated (FI) version.
The ports also have internal 120 Ohm terminator resistors and line biasing for RDM.
This product may only be used for
controlling dimmers and moving lights.
Using the product outside of these specifications
will remove all responsibility from the supplier.
Connections

__________________________________________________________________________________
ELC dmXLAN node3 User Manual
The dmXLAN node3 can be operated in 2 ways; either through the front panel or the
dmXLAN control software. The software can be downloaded from the ELC website at
www.elclighting.com. The front panel control options will be explained below.
Main display
Encoder +/- Change the view on the display to see the device ID, IP address,
status, software version, etc.
Press Encoder Enter the setup menu
Setup menu
Encoder +/- Select one of the setup items:
• Exit Setup
• DMX port 1
• DMX port 2
• DMX port 3
• Set ID
• Network Options
Press Encoder Activate the selected option
DMX port menu
Select mode Edit mode
Operation

__________________________________________________________________________________
ELC dmXLAN node3 User Manual
In select mode:
Encoder +/- Select different item
Press Encoder Go to Edit mode
In Edit mode:
Encoder +/- Change the value of the item
Press Encoder Go to Select mode
DMX port as output
When a port is set up as a DMX output it can operate in the following modes;
• Disabled à the DMX output is disabled
• Outzero à the DMX sends out a DMX test signal with all channels at 0%
• Single à the output sends out the DMX values of the selected (primary)
Art-Net, sACN or Shownet universe. The DMX output is enabled the first time
it detects the DMX universe on the network (or internal DMX inputs). If the
universe on the network fails, the DMX output will go into DMX hold.
• HTP à like single, but merges up to three DMX universes (primary,
secondary and tertiary) in highest takes precedence.
• Priority à Will output the Universe assigned to the primary if primary is
not present or available the universe assigned to secondary will be output
• FlexPatch à Can output a complex merge of three universes with a
different merge or patch per channel. This can be set up in the dmXLAN
software
DMX port as input
When a port is set up as a DMX input it can operate in the following modes;
• Disabled à the DMX input does nothing
• Normal à any valid DMX is sent onto the network (and internal use)
using the selected universe (Art-Net)
• Backup à the DMX input will not send data if the selected universe is
present on the network. If the selected universe is not present on the network
for several seconds and the input has valid DMX, then it will send DMX data.
If another sender starts sending the same universe, the input will go back into
backup mode.

__________________________________________________________________________________
ELC dmXLAN node3 User Manual
Set ID
If the node3 is being controlled by the dmXLAN software, an ID can be assigned to the
unit. The ID can be useful for preprogramming of the network.
Use the encoder in “Select” and “Edit” mode to change the 3 digits of the ID. The
digits are in hexadecimal format (16 possibilities 0-9, A-F). This means you can have
up to 4095 different ID’s in the system (ID 000 means that the ID is not used ---).
Network options
Use the “Select” and “Edit” modes to change the values of the IP address and the
netmask. For normal Art-Net operation, the netmask should be set to 255.0.0.0 and
the IP address should be between 2.0.0.1 and 2.254.254.254.
node3 Truss Mount
Power: 100-240 VAC 47-440 Hz 10VA max
Dimensions: 200 x 160 x 45 mm
Weight: 1.2 kg
node3 Surface Mount
Power: Power over Ethernet required on the internal connection
Dimensions: 140 x 85 x 50 mm
Weight: 0.6 kg
node3 Wall Mount
Power: Power over Ethernet required on the internal connection
Dimensions: 165 x 115 x 40 mm
Weight: 0.3 kg
node3 DIN
Dimensions: 105 x 90 x 60 mm
Weight: 0.2 kg
Technical specifications

__________________________________________________________________________________
ELC dmXLAN node3 User Manual
Read all instructions - especially the safety requirements - in the user manual before use.
Save these instructions - the safety and operating instructions should be retained for future
reference. Carefully follow all instructions.
Cleaning
Disconnect all connected supply and signal cables before cleaning the unit. Clean with a dry
cloth. Do not use any liquids or aerosols on the unit.
Usage
Do not use the unit near water or moisture. - Do not block any ventilation openings, they are
necessary for the essential airflow within the unit and protect it against overheating. - Install
in accordance with the manufacturer’s instructions. - Do not insert any objects through the
ventilation slots of the unit, as these could come in contact with live parts or could cause
short circuits. This could cause electric shock and/or fire. - Do not install near any heat
sources such as radiators, stoves or other apparatus (including amplifiers) that produce heat.
- Unplug this apparatus during lightning storms or when unused for long periods of time. Do
not place the unit on unstable surfaces. – Do not place any objects on the power cord.
Protect it from being walked on or pinched particularly at the plugs and the point where
they exit from the device. If the power cord or the mains plug is damaged, let a qualified
technician replace it immediately. - Do not defeat the safety purpose of the grounding plug.
A grounding plug has two blades and a third grounding connection. The third grounding
connection is provided for your safety. If the provided plug does not fit in your outlet,
consult an electrician for replacement of the obsolete outlet.
Servicing
Refer all servicing to qualified service personnel. Servicing is required when the apparatus
has been damaged in any way such as; damage to the power supply cord or plug, spillage of
liquids, objects falling into the apparatus, exposure to rain or moisture, abnormal operation
or falling damage. In all of the previous conditions, disconnect the main plug immediately
and call your distributor or technical support!
General safety instructions
General safety instructions

__________________________________________________________________________________
ELC dmXLAN node3 User Manual
Maintenance and service of the device may only be carried out by qualified service
personnel, as when opening and /or removing coverings of the device live parts may be
exposed causing the risk of an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the
presence of important operating and maintenance (servicing) instructions in the literature
accompanying the product.
The lightning flash with arrowhead symbol within an equilateral triangle is intended to
alert the user to the presence of uninsulated dangerous voltage within the product’s
enclosure that may be of sufficient magnitude to constitute a risk of electric shock to
persons.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE
Cautionary instructions

__________________________________________________________________________________
ELC dmXLAN node3 User Manual
We,
Manufacturers name: ELC lighting b.v.
Manufacturers address: Weerijs 8
5422 WV Gemert
the Netherlands
Herewith take the full responsibility to confirm that the product
Product Category: Lighting control equipment
Name of product: ELC-DLN3T / ELC-DLN3T_FI
Which refer to this declaration are manufactured in the Netherlands and complies with the
following product specifications and harmonized standards:
Safety: LVD (Low Voltage Directive) 2014/35/EU, EN62368-1
EMC: 2014/30/EG, EN55032
ROHS (II): 2011/65/EU
With the presumption that the equipment is used and connected according to the manual,
supplied with the equipment. All signal input- and output connections must be shielded and
the shielding must be connected to the ground of the corresponding plug.