Installation
Connect the cable provided to the Battery Charger Remote Control Socket and to
the Remote Control Display Panel Socket
. When connected, the remote control
panel will display the voltage of the selected battery and the battery charger status.
Switches
Output ON/OFF Switch
When in battery charging mode the output of the battery charger can be controlled
via the Output ON/OFF Switch. The switch does not switch off the battery charger
but switches off the charging current on both output terminals and enables the
voltage of the connected batteries to be displayed.
Battery Select Switch
Battery 1 will display the voltage of battery 1.
Battery 2 will display the voltage of battery 2.
LCD Light On
Press this button to illuminate the LCD Display.
Fault LED
Fault LED will light up whenever the Battery Charger has detected Short Circuit in
the Output, Severe Overloading, Over Temperature and Reverse Polarity
Connection.
REV.1 08/2009 7673-4120-2521
114.0
138.0
84.0
70.0±0.3
122.0±0.3
ø2.6±0.1
CUTOUT AREA
114x70mm
PANEL CUTOUT TEMPLATE
Actual Size