EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Electrolux
  6. •
  7. Ventilation Hood
  8. •
  9. Electrolux ICON E30DD75ESS User manual

Electrolux ICON E30DD75ESS User manual

Other manuals for ICON E30DD75ESS

5

Other Electrolux Ventilation Hood manuals

Electrolux EFV616K User manual

Electrolux

Electrolux EFV616K User manual

Electrolux EFC 9420 User manual

Electrolux

Electrolux EFC 9420 User manual

Electrolux EFA90245X User manual

Electrolux

Electrolux EFA90245X User manual

Electrolux EFP 662 Specification sheet

Electrolux

Electrolux EFP 662 Specification sheet

Electrolux EFC 6426 User manual

Electrolux

Electrolux EFC 6426 User manual

Electrolux EFT602208OX User manual

Electrolux

Electrolux EFT602208OX User manual

Electrolux MCH 660 User manual

Electrolux

Electrolux MCH 660 User manual

Electrolux E:Line ERCE90AS User manual

Electrolux

Electrolux E:Line ERCE90AS User manual

Electrolux ICON RH36WCT6GS Installation instructions

Electrolux

Electrolux ICON RH36WCT6GS Installation instructions

Electrolux DI 8610 User manual

Electrolux

Electrolux DI 8610 User manual

Electrolux LFG517X User manual

Electrolux

Electrolux LFG517X User manual

Electrolux EFP60566OX User manual

Electrolux

Electrolux EFP60566OX User manual

Electrolux EFC 640 User manual

Electrolux

Electrolux EFC 640 User manual

Electrolux EFC 1430 User manual

Electrolux

Electrolux EFC 1430 User manual

Electrolux EFB90581OX User manual

Electrolux

Electrolux EFB90581OX User manual

Electrolux LFP716W User manual

Electrolux

Electrolux LFP716W User manual

Electrolux 341 D User manual

Electrolux

Electrolux 341 D User manual

Electrolux ICON E30DD75ESS User manual

Electrolux

Electrolux ICON E30DD75ESS User manual

Electrolux LFD619Y User manual

Electrolux

Electrolux LFD619Y User manual

Electrolux LFP216S User manual

Electrolux

Electrolux LFP216S User manual

Electrolux EFC 9490 User manual

Electrolux

Electrolux EFC 9490 User manual

Electrolux EFP 60310 User manual

Electrolux

Electrolux EFP 60310 User manual

Electrolux ICON E30WV60EPS User manual

Electrolux

Electrolux ICON E30WV60EPS User manual

Electrolux EFP 6500 User manual

Electrolux

Electrolux EFP 6500 User manual

Popular Ventilation Hood manuals by other brands

Haier CXW-219-D67 null

Haier

Haier CXW-219-D67 null

emmeti RECUPA MED A-140 Installation and use manual

emmeti

emmeti RECUPA MED A-140 Installation and use manual

Nibe F135 user manual

Nibe

Nibe F135 user manual

Zephyr Spruce AK9834BS Use, care and installation guide

Zephyr

Zephyr Spruce AK9834BS Use, care and installation guide

Kuppersberg INTRO 60 Technical Passport

Kuppersberg

Kuppersberg INTRO 60 Technical Passport

Hisense MH6INBG manual

Hisense

Hisense MH6INBG manual

Miele DA 1255 Operating and installation instructions

Miele

Miele DA 1255 Operating and installation instructions

Broan 46000 Specification sheet

Broan

Broan 46000 Specification sheet

GE Profile PV977 Owner's Manual & Installation Instructions

GE

GE Profile PV977 Owner's Manual & Installation Instructions

FALMEC FFRIA24W5FS Instruction booklet

FALMEC

FALMEC FFRIA24W5FS Instruction booklet

Whirlpool RH2600XL-1 SERIES installation instructions

Whirlpool

Whirlpool RH2600XL-1 SERIES installation instructions

ETNA AV360RVS Instructions for use

ETNA

ETNA AV360RVS Instructions for use

JUNO JDF603E6 installation manual

JUNO

JUNO JDF603E6 installation manual

Miele DA 6708 D Operating and installation instructions

Miele

Miele DA 6708 D Operating and installation instructions

Tricity Bendix LE 150 Installation & operating instructions

Tricity Bendix

Tricity Bendix LE 150 Installation & operating instructions

AEG X68163BV1 user manual

AEG

AEG X68163BV1 user manual

AEG 125 D operating instructions

AEG

AEG 125 D operating instructions

Smeg KSEV97X instruction manual

Smeg

Smeg KSEV97X instruction manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

30" DOWNDRAFT VENT
FEATURES
Installation Type
Vent Motor Location
Air Discharge
Air Delivery (CFM)
Intake Area
Controls
Infinite-Speed Blower*
Dishwasher Safe Stainless Steel Filters
Exhaust Duct
Duct Required
SPECIFICATIONS
Overall Dimensions –
Height (Including 10" Rise)
Width
Depth
Voltage Rating
Connected Load (kW Rating) @120 Volts‡
Motor Power Cord Location
Shipping Weight (Approx.)
‡For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate
ground wire. Appliance must be grounded for safe operation.
*The blower assembly part number is 5304444802 — shipped in separate box.
NOTE: Always consult local and national electric codes. Refer to Product Installation Guide
for detailed installation instructions on the web at electroluxicon.com.
Specifications subject to change.
Countertop Mount
External
Down
1600
10"
Dial
Yes
Yes
External
3-1/4" x 10"
40"
30"
3-27/32"
120V/60Hz/15A
1.0
Bottom Right
48 Lbs.
electroluxicon.com
Infinite-Speed Control
The ultraquiet blower allows you to dial in the
precise airflow needed.
Removable, Easy-Clean Filters
Filters are easy to remove and clean in your
dishwasher to restore to like-new condition.
10"-High Intake
When activated, the downdraft vent rises 10" to
capture even the most stubborn cooking odors.
Slim Style
Designed to work in perfect harmony with your
approved gas or electric cooktop.
Downdraft Vent
E30DD75ESS
30" Downdraft Vent Specifications
•
Voltage Rating –120V/ 60Hz/15 Amps
•
Connected Load (kW Rating) @120 Volts = 1.0kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•
Amps @120 Volts = 8.0 Amps
•
Do not use same circuit as cooktop.
•
Always consult local and national electric codes. Check local
building codes for installation requirements, as they may vary per locale.
•
1,600 CFM remote exhaust blower (PN# 5304444802) included
with vent – shipped in separate box.
•
Vent must be installed in vertical orientation only.
•
Vent unit outside of building only.
•
Exhaust Duct Required – 3-1/4"x10" (3-1/4"x10" to round transition
duct will be needed)
•
Do not use flexible duct. Round duct instead of rectangular duct
recommended, especially when elbows are required.
•
When multiple elbows are necessary, ensure a minimum of 24" of
straight duct between any two elbows.
•
Thermal breaks such as short section of nonmetallic duct, should
be used in areas of extreme cold.
•
For most efficient airflow exhaust, use a straight run or as few elbows
as possible.
•
Cold weather installations should have additional backdraft
damper installed.
•
Installing a Downdraft Vent in combination with any gas cooking surface
will affect optimum burner efficiency.
•
Downdraft Vents can NOT be used in combination with any cooktop
backsplash.
•
Downdraft Vent model E30DD75ESS is approved to be used in
combination with Electrolux ICON®Drop-In Cooktop models
E30EC65ESS, E30EC70FSS, E30IC75FSS, E30IC80ISS, E30GC64ESS,
E30GC70FSS;
and Electrolux ICON®Slide-In Cooktop model E30GC74GPS.
(For detailed countertop preparation, refer to Drop-In and Slide-In
Cooktop/Downdraft Vent Countertop Preparation pages on web.)
•
Proper combination installation of Electrolux ICON®Downdraft Vent model
E30DD75ESS and approved 30" Gas Slide-In Cooktop will require
cooktop power cord to be relocated to underside of unit. (For details,
refer to 30" & 36" Gas Slide-In Cooktop Power Cord Relocation
Instructions on web.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Downdraft Vent
E30DD75ESS
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
•250 Bobby Jones Expressway •Augusta, GA 30907 •1-877-4electrolux (1-877-435-3287) •
electroluxicon.com
CANADA
•5855 Terry Fox Way •Mississauga, ON L5V 3E4 •1-800-265-8352 •
electroluxicon.ca
E30DD75ESS 09/09 © 2009 Electrolux Home Products, Inc. Printed in the U.S.A.
For Use With Duct Size
30" Cooktops 31/4" x10"
Specifications
Against-Wall
Downdraft
Installations
213/16"
115/16"
3"
Wallboard
Studwall
21/8"
9/32"
Cooktop/
Range
1/4" min.
3/4" max.
backsplash
thickness
Roof Exhaust
Blower
Stud wall
Backsplash
31/4"x10"
to round
transition
Wallboard
31/4"x10"duct
31/4"x10"
90°elbow
Anchoring leg Finished floor
Roof
Cooktop
Vent unit
Motor cover
Exterior Wall Exhaust
Wallboard
Cooktop
Outside wall
Blower
Stud wall
Backsplash
31/4"x10"duct
31/4"x10"
90°elbow
Anchoring leg Finished floor
Vent unit
Motor cover
Cap Profile
13/16"
21/2"
Front
Anchoring legs
15/8"x16" exhaust duct Electrical access panel
81/2"
31/4"x10"
rear exhaust
duct
30"
257/8"
6"
Motor cover
10"
30"
15/8"x16"
exhaust ducts
27 3/4"Countertop
Finished
Floor
48", 3-prong,
grounded
power cord
Side
Stiffener
15/8"x16"
exhaust duct
31/4"x10"
exhaust duct 3/4"33/4"
1813/16"
97/16"
3/8"
Finished Floor
Drop-In Cooktop/Downdraft Vent
Countertop Preparation Specifications
•
For detailed Drop-In Cooktop installation, refer to model-specific product
page and installation guide on web. Plan installation so that all required
minimum clearances between cooktop, overhead cabinets and adjacent
vertical walls are provided.
•
Position cooktop/vent cutout so all required minimum clearances are met.
•
Minimum flat countertop area must meet or exceed combined overall
width and depth as shown. Standard 25" countertop depth may NOT be
adequate for some cooktop/vent installations, especially with backsplash.
•
Separate circuits required for cooktop and vent. (Refer to product-specific
electrical specifications.)
•
Always consult local and national electric and gas codes. Check local
building codes for installation requirements, as they may vary per locale.
Downdraft Vent Specifications
•
For detailed Downdraft Vent installations, refer to model-specific
product page and installation guide on web.
•
Voltage Rating –120V/ 60Hz/15 Amps
•
Connected Load (kW Rating) @120 Volts = 1.0kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•
Amps @120 Volts = 8.0 Amps
•
Vent unit outside of building only.
•
Vent must be installed in vertical orientation only.
•
1,600 CFM remote exhaust blower (PN# 5304444802)
included with vent – shipped in separate box.
•
Do not use flexible duct. Round duct instead of rectangular duct
recommended, especially when elbows are required.
•
When multiple elbows are necessary, ensure a minimum of 24" of
straight duct between any two elbows.
•
Thermal breaks such as short section of nonmetallic duct, should
be used in areas of extreme cold.
•
For most efficient airflow exhaust, use a straight run or as few elbows
as possible.
•
Cold weather installations should have additional backdraft damper
installed.
•
Installing a Downdraft Vent in combination with any gas cooking
surface will affect optimum burner efficiency.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Drop-In Cooktop/Downdraft Vent
Countertop Preparation
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
•250 Bobby Jones Expressway •Augusta, GA 30907 •1-877-4electrolux (1-877-435-3287) •
electroluxicon.com
CANADA
•5855 Terry Fox Way •Mississauga, ON L5V 3E4 •1-800-265-8352 •
electroluxicon.ca
DIC_DDV_PREP 09/09 © 2009 Electrolux Home Products, Inc. Printed in the U.S.A.
Countertop Preparation for 30" & 36" Drop-In Cooktop/Downdraft Vent Installation
29/16"
1/4"min.
flat ledge
Backsplash
3/4"max.
* Overall flat ledge behind
backside of cabinet front
** Minimum flat surface required
to fit top surface of cooktop
and downdraft vent cap
A
Vertical noncombustible surface - rear wall
25"
B
Top
231/4"
min. Flush with
back side of
cabinet front
D*
E**
C
Stiffener
Back side of
cabinet front
Vent unit
21/8"Countertop
raised lip
Countertop
backsplash
Downdraft
chimney top
Cooktop
25"
(standard countertop)
*
231/4"min.
213/16"
3"
Vertical noncombustible surface - rear wall
Studwall
3/4" max. backsplash thickness
1/4"min. flat ledge
115/16"
9/32"
213/16"
Cooktop Installation Note:
To ensure proper installation, refer to model-specific installation
guide on web for cooktop dimensions, cutout dimensions and
cabinet requirements. Due to varying cooktop depths, tight fit
is possible between cooktop and vent.
Countertop Preparation Note:
Be aware of areas of potential interference called out in
illustration. Countertop with raised lip and/or backsplash may
not allow enough flat area for proper installation, 2-13/16"
of flat countertop required behind cooktop. No gap required
between back of cooktop and front of downdraft trim piece.
*Standard 25" countertop depth may NOT be adequate for
some cooktop/vent installations, especially with backsplash.
E30DD75ESS/30" Cooktop Cutout Dimensions
30" Cooktops A B C D E
E30EC65ESS 30" 273/4" 20 3/8" 23 3/16" 24 3/16"
E30EC70FSS 30" 273/4" 20 1/4" 231/16" 241/16"
E30GC64ESS 271/2" 273/4" 19 7/8" 2211/16" 2311/16"
E30GC70FSS 281/2" 273/4" 19 3/4" 22 9/16" 23 9/16"
E30IC80ISS 293/4" 273/4" 201/2" 23 5/16" 24 5/16"
E36DD75ESS/36" Cooktop Cutout Dimensions
36" Cooktops A B C D E
E36EC65ESS 36" 33 3/4" 20 3/8" 23 3/16" 24 3/16"
E36EC70FSS 36" 33 3/4" 201/2" 235/16" 245/16"
E36GC65ESS 33 3/4" 33 3/4" 19 7/8" 2211/16" 2311/16"
E36GC70FSS 341/2" 33 3/4" 19 3/4" 22 9/16" 23 9/16"
E36IC80ISS 36" 33 3/4" 201/2" 23 5/16" 24 5/16"
For detailed cooktop and
downdraft vent installation
specifications, refer to
model-specific product
page and installation
guide on web
Slide-In Cooktop/Downdraft Vent
Countertop Preparation Specifications
•
For detailed Slide-In Cooktop installation, refer to model-specific product
page and installation guide on web. Plan installation so that all required
minimum clearances between cooktop, overhead cabinets and adjacent
vertical walls are provided.
•
Position cooktop/vent cutout so all required minimum clearances are met.
•
Minimum flat countertop area must meet or exceed combined overall
width and depth as shown. Standard 25" countertop depth is NOT
adequate for slide-in cooktop/vent installations.
•
Separate circuits required for cooktop and vent. (Refer to product-specific
electrical specifications.)
•
Always consult local and national electric and gas codes. Check local
building codes for installation requirements, as they may vary per locale.
•
Proper combination installation will require 30" & 36" Gas Slide-In
Cooktop power cord to be relocated to underside of unit. (For details,
refer to 30" & 36" Gas Slide-In Cooktop Power Cord Relocation
Instructions on web.)
Downdraft Vent Specifications
•
For detailed Downdraft Vent installations, refer to model-specific
product page and installation guide on web.
•
Voltage Rating –120V/ 60Hz/15 Amps
•
Connected Load (kW Rating) @120 Volts = 1.0kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for
safe operation.)
•
Amps @120 Volts = 8.0 Amps
•
Vent unit outside of building only.
•
Vent must be installed in vertical orientation only.
•
1,600 CFM remote exhaust blower (PN# 5304444802) included with
vent – shipped in separate box.
•
Do not use flexible duct. Round duct instead of rectangular duct
recommended, especially when elbows are required.
•
When multiple elbows are necessary, ensure a minimum of 24" of straight
duct between any two elbows.
•
Thermal breaks such as short section of nonmetallic duct, should be
used in areas of extreme cold.
•
For most efficient airflow exhaust, use a straight run or as few elbows
as possible.
•
Cold weather installations should have additional backdraft damper
installed.
•
Installing a Downdraft Vent in combination with any gas cooking surface
will affect optimum burner efficiency.
•
Downdraft Vents can NOT be used in combination with any cooktop
backsplash.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
•250 Bobby Jones Expressway •Augusta, GA 30907 •1-877-4electrolux (1-877-435-3287) •
electroluxicon.com
CANADA
•5855 Terry Fox Way •Mississauga, ON L5V 3E4 •1-800-265-8352 •
electroluxicon.ca
SIC_DDV_PREP 09/09 © 2009 Electrolux Home Products, Inc. Printed in the U.S.A.
Countertop Preparation for 30" & 36" Slide-In Cooktop/Downdraft Vent Installation
Cooktop Installation Note:
To ensure proper installation, refer to model-specific installation
guide on web for cooktop dimensions, cutout dimensions and
cabinet requirements.
Countertop Preparation Note:
Countertop with backsplash may not allow enough flat area for
proper installation, 2-13/16" of flat countertop required behind
cooktop. No gap required between back of cooktop and front
of downdraft trim piece.
*Standard 25" countertop depth is NOT adequate for slide-in
cooktop/vent installations.
Stiffener Back side of
cabinet front
Vent unit
Downdraft
chimney top
Slide-In Cooktop
2513/16"
End of cooktop
support platform
Countertop*
213/16"
3"
Vertical noncombustible surface - rear wall
Studwall
1/4"min. flat ledge
115/16"
9/32"
E36DD75ESS/36" Cooktop Cutout Dimensions
36" Cooktops A B C D E
E36EC75DSS 3515/16" 35 3/16" 22" 2513/16" 33 3/4"
E36EC75ESS 3515/16" 35 3/16" 22" 2513/16" 33 3/4"
E36EC75HSS 3515/16" 35 3/16" 22" 2513/16" 33 3/4"
E36GC75DSS* 3515/16" 35 3/16" 22" 2513/16" 33 3/4"
E36GC75ESS* 3515/16" 35 3/16" 22" 2513/16" 33 3/4"
E36GC75GSS* 3515/16" 35 3/16" 22" 2513/16" 33 3/4"
E36GC76EPS* 3515/16" 35 3/16" 22" 2513/16" 33 3/4"
E36GC76GPS* 3515/16" 35 3/16" 22" 2513/16" 33 3/4"
E30DD75ESS/30" Cooktop Cutout Dimensions
30" Cooktop A B C D E
E30GC74GPS* 2915/16"293/16"22" 2513/16" 273/4"
*Proper combination installation will require cooktop power cord
to be relocated to underside of unit.
(For details, refer to 30" & 36"
Gas Slide-In Cooktop Power Cord Relocation Instructions page.)
For detailed cooktop and
downdraft vent installation
specifications, refer to
model-specific product
page and installation
guide on web
71/4"
1/4"min.
flat ledge
Downdraft vent cutout opening
in cooktop support platform
BA
1"countertop
overhang
C
29/16"71/2"
E
D
Slide-In Cooktop/Downdraft Vent
Countertop Preparation