Contents Page
PRAFACE............................................................................................................ 4
Contents............................................................................................................. 5
Before Use ......................................................................................................... 6
1. GENERAL DESCRIPTION .................................................................................. 8
1.1 ThruScan s3 Walk Through Metal Detector............................................ 9
1.2 ThruScan s9 Walk Thru Metal Detector…………………………………………10
1.3 ThruScan sX Walk Through Metal Detector..........................................11
1.4 ThruScan sX-i Walk Through Metal Detector........................................12
1.5 ThruScan sX-WP Walk Through Metal Detector...................................13
2. INSTALLATION INSTRUCTIONS ......................................................................14
2.1 Site Selection ............................................................................................14
2.2 Assembling & Mounting ..........................................................................14
2.2.1 Assembling.............................................................................................14
2.2.2 Assembling.............................................................................................12
2.2.3.4. Assembling ........................................................................................14
2.2.- 5.6.7.8.9.10.11.12.13.14 Assembling ...............................................15
3. CONTROL DISPLAY PANEL & INDICATION INFORMATION ........................16
3.1 Control Panel.............................................................................................16
3.1.1 LCD Display ............................................................................................16
3.1.2 Alarm Locater Display ..........................................................................16
3.1.3 LED VU Display.......................................................................................16
3.1.4 Battery Indicator....................................................................................17
3.1.5 Pacing Light Indicator-(Traffic Lights) ................................................17
3.2 Touch Pads ...............................................................................................17
3.2.1 ON- OFF Button ......................................................................................17
3.2.2 RUN(X) Button........................................................................................17
3.2.3 SEL(√) Button .........................................................................................17
3.2.4 Up-Down Buttons...................................................................................17
3.3 Traffic Lights..............................................................................................18
3.4 Zone (Indicator) Light’s ............................................................................18
3.5 Various Alarms..........................................................................................18
3.6 Relay-Contact Outputs .............................................................................19
3.7 Synchronization and Remote Control Outputs.....................................19
4. PROGRAMMING & SET UP .............................................................................20
4.1 Program MENU..........................................................................................20
4.1.1 Security Level & Sensitivity Level Adjustments................................20
4.1.2 Zone Security Level & Sensitivity Level Adjustment (sX)................23
4.1.3 Auto Detection & Auto Sensitivity Assign (sX)..................................24
1

Contents Page
4.1.4 Alarm & Tone Volume Adjustment.....................................................25
4.1.5 Alarm Counter........................................................................................25
4.1.6 In-Coming / Out-Going Counter (Traffic Counts)...............................25
4.1.6.1 For ThruScan s3 .................................................................................25
4.1.6.2 For ThruScan s9/sX/sX-i/sX-WP .....................................................26
4.1.7 Factory Settings.....................................................................................26
4.1.8 Language Selection ..............................................................................27
4.1.9 Counter Visibility....................................................................................27
4.1.10 New Password.....................................................................................27
4.1.11 Environment Noise Level ...................................................................28
4.1.12 Pass Sensor .........................................................................................28
4.1.13 Alarm Tone Duration Select ..............................................................28
5. SYSTEM OPERATION .......................................................................................29
5.1 Normal Operating Mode ..........................................................................29
5.2 Routine Tests.............................................................................................29
5.3 Alarm State................................................................................................30
6. TECHNICAL SPECIFICATIONS ........................................................................30
6.1 Electronics..................................................................................................30
6.2 Detection Field ..........................................................................................30
6.3 Language ...................................................................................................31
6.4 Self Test......................................................................................................31
6.5 Sensitivity...................................................................................................31
6.6 Memory ......................................................................................................32
6.7 Traffic Counter...........................................................................................32
6.8 Tamper Proof.............................................................................................32
6.9 Regulatory Information............................................................................32
6.10 Infrared Sensor .......................................................................................32
6.11 Electromagnetic Noise & Interference Rejection..............................33
6.12 Masking ...................................................................................................33
6.13 Synchronisation ......................................................................................33
6.14 Electrical Requirements........................................................................33
6.15 Operating Temperatures .......................................................................34
6.16 Humidity ..................................................................................................34
6.17 Throughput Rate.....................................................................................34
6.18 Weight......................................................................................................34
6.19 Warranty Period......................................................................................34
6.20 Dimensions .............................................................................................34
7. OPTIONS............................................................................................................35
7.1 Remote Control Package ........................................................................35
2

Contents Page
7.1.1 SCADA Remote Control Software-SRC ..............................................35
7.1.2 Specific MODEM for Remote Control Program ................................36
7.1.3 Special CABLE for Remote Control Program ....................................36
7.2 Outdoor Package ......................................................................................36
7.2.1 Rain Protect Shelter.............................................................................36
7.2.2 Side Panel Protection ...........................................................................37
7.3 Battery Group ............................................................................................37
7.4 WTMD Wheeler .........................................................................................37
7.5 Carriage Bag..............................................................................................37
7.6 IRDA Remote Control...............................................................................37
8. MAINTENANCE & REPAIR...............................................................................37
8.1 Periodic Maintenance ..............................................................................37
8.2 Repair .........................................................................................................34
8.3 Module Replacement...............................................................................38
8.4 Warranty Provisions .................................................................................38
9. TROUBLE SHOOTING .......................................................................................39
9.1 Frequently Asked Questions ...................................................................39
9.2 Mounting Questions .................................................................................40
9.3 Operational Questions .............................................................................42
10. APPENDIX.......................................................................................................44
10.1 Certificate of Expertise .........................................................................44
10.2 SRC SCADA Remote Control ................................................................44
10.2.1 ThruScan s9-SRC SCADA Program Manual ....................................45
10.2.2 ThruScan sX-SRC SCADA Program Manual ....................................46
10.3 IRDA Remote Control Unit Manuel......................................................47
10.4 Users Manuel For Wheeled Transportation …………………................ 48
10.5 Certificate of Warranty ..........................................................................49
© 2005 Elektral A.Ş. – ThruScan Metal Detectors
All rights reserved. Protected by Law Number 4110 and Ideas and Works of Art Law 5846, unless a written consent by its copyright owner, Elektral A.Ş. according to the 52. Article is provided, this manual, under no
circumstances may be processed, copied, its duplicated copies published, represented, presented, in any form or by any means by mechanical and/or electronic ways be transmitted or used.
3

PREFACE
Dear User;
You have taken some serious measures for the security of the Entrance-Control of
necessary environments with the Magnetic Walk Through Metal Detector-(WTMD)
you have purchased. Thank you for selecting of ELEKTRAL warranty.
With Elektral-
ThruScan
(s3/s9/sX/sX-i/sX-WP) Multizone Walk Through Metal
Detectors, your estates will be more secured.
ThruScan
; are our metal detectors which include norms and regulations written in
this field, approved by international markets with incredible references.
ThruScan
will receive your approval as well with their quality, service guarantee
and economy.
Thank you for selecting a product manufactured by Elektral A.S. at an international
alliance. We hope to meet at many professional Elektral products.
Please make sure to read this manual carefully before start up this versatile
electronic equipment.
Elektral Products,
Are produced in environment friendly modern facilities
Without no harm to the nature and to living creatures.
MADE IN TURKEY
ALTERATIONS RESERVED.
NO CLAIMS CAN BE ACCEPTED BY OUR FIRM REGARDING THE APPLICATIONS OF
THIS INSTRUMENT FROM THE SECOND OR THIRD PARTIES.
ALL THE RIGHTS RESERVED.
PLEASE FIND OUR “Conditions of Sales, Delivery & Warranty” at our Web.
4

C O N T E N T S
Procedures and Safety Warnings before using
ThruScan
Technical specifications of
ThruScan
Preparations Mounting
ThruScan
Programming and further procedures
The arrow-end lightning symbol inside
the equilateral triangle informs the user
that in the context of the product, there
is enough amount of ‘uninsulated’
dangerous voltage to cause an electric
shock.
DO NOT OPEN ThruScan
ELECTRONIC CASE
RISK OF ELECTRIC SHOCK
The exclamation mark inside the eqilateral triangle informs
the user that there are important instructions of useage and
information inside the booklets given with the equipment.
5

Necessary Procedures and Safety Warnings
Prior to Using
ThruScan
Avoid direct light from entering to the infrared sensors apertures
(see Sec. 6.10) of your
ThruScan
.
Leave minimum 1m between your
ThruScan
and any objects such
as metal doors, X-Rays, turnstiles, as such.
Do not place any covers, plating or loads that would induce weight
over your
ThruScan
unless being recommended by the factory.
Do not drill any holes on the panels of your
ThruScan
under any
circumstances.
Your
ThruScan
is secured both by a mechanical lock and an
electronic PIN CODE as a precaution towards unauthorized people.
Do not share your password. Contact factory when it is fogotten.
Assemble your
ThruScan
on a horizontal and flat floor. Make sure to
fix it firmly to the floor.
Do not assemble your
ThruScan
on a floor that is not rigid or stable.
Do not let unauthorized persons to interven
ThruScan
s electronic
units. Contact your dealer or the factory for authorized service staff.
Use soft, damp clothing to clean your
ThruScan
. Always unplug
your equipment during cleaning.
Never Operate! your equipment through mains without norm ground
ThruScan
is designed to operate between 70~270 VAC / 50Hz~60
Hz on a switching power unit. However you normally should operate
on 110-220VAC.
6

CAUTION! Misuse of this equipment specified by the manufacturer may
result in damage to property or injury to persons.
Technical Specifications:
Electrical : Select 110VAC or 220VAC by the Switching Supply Module by opening the
cover of the control unit.(Factory default 220 VAC)
70 – 270 VAC (Supply should be earthed & stable)
10 Watts standby, 20 Watts max in alarm. A-Class Energy Save
Frequency: 50/60 Hz
Maximum Relative Humidity : 95% non-condensing
Operating Temperature : -20° ~ +70º C
WARNING:
All of the ThruScans and the PC of the SRC-SCADA Remote Control, must be powered at
the same point for the same "ground/earth". Otherwise problems may occur due to
potential difference.
Standards:
The units conform to NILECJ L/1-3 standards
ThruScan
is within the magnetic emission limits approved by FDA (American Food & Drug
Administration). It has been certified by experts that has no effects on the peacemakers, the
pregnant women and as well at magnetic media. A “report of expertise” on this issue is presented
in Attachment-1. See Section 10.1.
Protect your
ThruScan
from direct rain, mist and/or condensation and place water level on a
stable floor without vibration.
DO NOT place the
ThruScan
close to telephone lines, television monitors, electric motors,
transformers, power cables, or control circuits; excessive electrical noise may cause false
measurements.
CAUTION! ThruScan must be firmly anchored to the floor to reduce the accidental risk
of fall down and thus injure persons or cause property damage.
Do not drive nails, screws or drill holes into the side panels.
Screen only when the green “ready LED” is on to ensure proper operation.
Test your apparatus daily especially against environmental displacements.
NOTE:
Security metal detectors are designed to use within a total security-screening
plan. It is the last user’s responsibility to define the overall plan and ensure that
it operates effectively.
7

1. GENERAL DESCRIPTION
ThruScan
s3/s9/sX/sX-i/sX-WP WTMD’s all are simple to operate and with advanced
microprocessor controlled, digital pulse induction utilizing VLF Technology that provide superior
metal discrimination and detection. It is a versatile and easily portable walk-through metal
detection unit providing a high level of detection with a walk-thru rate of up to 60 persons per
minute.
(* for ThruScan s3 aprx. 30 persons/min)
ThruScan
s9/sX/sX-i/sX-WP has an enlarged stable and homogeneous detection field that
comprises of several horizontal and vertical zones, which can detect metal objects within 9 separate
scanning zones of the WTMD
(*for ThruScan s3 three zones).
Detection field homogeneity is
improved all through the passage dramatically by revealing the exact locations that are threat. The
operator need only to search the
ThruScan
’s s9/sX/sX-i/sX-WP indicated by the side panel lights.
See Section 3.4
A bright, highly visible LED (Light Emitting Diode) VU display provides a visual indication of the level
of metals detected within the field of detection. Operator may also approximate the magnitude of
the metal by warning sound without looking the
ThruScan
’s VU-meter on the Control Panel.
Traffic LED’s (Green or Red) on the side panels (ENTER SIDE) show if WTMD is ready for passage.
If the lights show green the gateway may be entered, if the lights show red the person must not
enter. See Section 3.3
(*for
ThruScan
s3 traffic lights are under Control Panel at gateway)
Zone lights show the location of the metal object whether it is on the left, right, top, bottom or at
the centre of the body and are located on the side panels of the exit side of the gateway. Zone
lights originate from LED arrays of 2x6 to show 9 zones. These zones are being indicated on the
control panel also by “Graphic Zone Leds (Locator)”.
(*for s3, display only at control panel)
A backlited LCD Display (monitor), (See Program MENU Section 3.1.1) is located on the overhead
Control Unit and display operational information, including program, alarm and sensitivity settings
as well as a traffic count of both in-coming and out-going passing’s.
A see through cover with mechanical lock
(* optional for ThruScan s3)
enable to access to
Control Unit in order to prevent unauthorized tampering. Calibration and control settings are
further protected by a Programmable 4 digit PIN CODE. See Section 6.8
ThruScan
(s9/sX/sX-i/sX-WP) also incorporates an integral UPS battery back up
(*optional for
ThruScan s3)
supply mains to protect the mains from power fluctuations and to maintain
operation for up to 4 hours (longer times optional) in case of mains failure. The WTMD
automatically shuts itself down in case of the lack of the necessary voltage.
Another unique feature of the
ThruScan
sX/sX-i/sX-WP is its ability to monitor up to 99 separate
(* for ThruScan s3/s9 sixteen WTMDs for 1 PC)
ThruScan
units remotely from a PC or
even remotely from anywhere in the world via a standard and satellite(thuraya) telephone lines
under a modem connection. The hardware for this feature is built in as a standard and the SCADA
software and connection cables are available separately as an option. See Section 7.1
Other features of the
ThruScan
include superior sensitivity, stability and noise rejection. All
electronics are built into the overhead Control Unit, connection with the panels provided with
sockets, eliminating the problems often associated with a cable-connected console.
8

1.1
ThruScan
s3
•International Norms (NILECJ-0601 L1-3 / IP53/ IEC
348 Class1, in accordance with CE, Manufactured in
a ISO 9001-2000 certified ),
•MULTIZONE, 3 “Real Detection Zone” (Left, Middle,
Right),
•Auto Calibration,
•Compact Design,
•VLF Technology- human friendly certification,
•Green/Red Bicolor Traffic Through LEDs,
•10 Sensitivity Levels,
246 adjustable levels at each, applicable to all zones,
separately (Program 1 fixed to NILECJ - NC),
•Graphic Zone Display on control panel,
•Display of Metal Density at 10 levels
(green/yellow/red) VU meter,
•Environmental Magnetic Noise Level Display,
•10 different and 10 level adjustable warning tones,
•Alarm Counter,
•In Counter(one way) at 5 Digits (Visible/Invisible),
•4 Digit changeable PIN CODE,
(* optional Mechanic
Lock)
•Automatic Failure Display,
•Reloading the Factory Default Settings by 1 touch
button,
•Easy Programming & Monitoring with LCD display
•Standard MENU in 4 Languages (English, German,
Turkish and Spanish),
•Additional NO/NC Relay Output for peripheral
security apparatus as turnstiles, cameras, recorders etc. during alarming
•Switching Power Supply,
(*option UPS).
•Modem/RS232 Output, for Remote Data Communication (SCADA SOFTWARE),
•Unique Designs & in variety of colours,
•Easy mounting/dismounting in aprx.15 minutes,
•With the Outdoor Package can be used at outside
(*option),
•Exported to 4 continents.
NOTE: You may reach ThruScan s3 Photo Gallery through www.elektral.com.tr website.
9

1.2
ThruScan
s9
ThruScan
s9 was chosen, “The Best Deal” in Dubai Safety Exhibition-2001, with
the norms it provides, its specifications, performance and economic advantages.
Here are some of the technical superiorities for
ThruScan
s9 :
•International Norms (NILECJ-0601 L1-3 / IP53/
IEC 348 Class1, in accordance with CE,
Manufactured in a ISO 9001-2000 certified ),
•MULTIZONE, 9 Real Detection Zone,
•Auto Calibration,
•Compact Design,
•VLF Technology- human friendly certified,
•Green/Red Bicolor Traffic Through LEDs,
•LED Illuminated Warnings at the Control and Side
Panels,
•10 Sensitivity Levels,
246 adjustable levels at each, applicable to all
zones, separately (Program 1 fixed to NILECJ - NC),
•Graphic Zone Display on control unit,
•Display of Metal Density at 10 level
(green/yellow/red) VU meter,
•Environmental Magnetic Noise Level Display,
•10 different and 10 level adjustable warning tones,
•Alarm Counter,
•In & Outgoing Counters separately at 5 Digits
(Visible/Invisible),
•Mechanical Lock For Control Panel and 4 Digit
changeable PIN CODE,
•Automatic Failure Display,
•Reloading the Factory Default Settings by 1 touch
button,
•Easy Programming & Monitoring with LCD display
•Standard MENU in 4 Languages (English, German,
Turkish and Spanish),
•Additional NO/NC Relay Output for peripheral security apparatus as turnstiles,
cameras, recorders etc. during alarming,
•UPS-Uninterrupted Switching Power Supply, 4 Hours operation without mains,
•Modem/RS232 Output, for Remote Data Communication (SCADA SOFTWARE),
•Unique Designs & in variety of colours,
•Easy mounting/dismounting in aprx.15 minutes,
•With the Outdoor Package can be used at outside
(*option),
•Exported to 4 continents.
NOTE: You may reach ThruScan s9 Photo Gallery through www.elektral.com.tr website.
10

1.3
ThruScan
sX
ThruScan
sX was introduced as “The Breaking News” at Abu Dhabi –Middle East
Security & Safety Exhibition-2003 with its innovative superior spec, compliance to
norms, contemporary design, performance and economic advantage, in comparison to
its counterparts. It’s widely used and preferred all around the world, protecting
millions of people against terror.
•International Norms (NILECJ-0601 L1-3 / IP54/
IEC 348 Class1, in accordance with CE,
Manufactured in a ISO 9001-2000 certified ),
•MULTIZONE, 9 Real Detection Zone,
•Auto Calibration,
•VLF Technology- human friendly,
•Green/Red Bicolour Traffic Through LEDs,
•LED Illuminated Warnings at the Control and
Side Panels,
•20 Sensitivity Levels, 246 adjustable levels at
each, applicable to all zones separately
(Program 1 fixed to NILECJ -NC), 5 fixed
International Sensitivity Standard (optional),
•Separate Zone Sensitivity Settings,
•Automatic Sensitivity Program selects the
correct sensitivity for a specific weapon or test
object-(fast consistent calibration) “SMART
DETECTOR”,
•Graphic Zone Display,
•Display of Metal Density at 10 level
(green/yellow/red) VU meter,
•Environment Magnetic Noise Level Display,
•10 different and 10 level adjustable warning
tones,
•Alarm Counter,
•In & Outgoing Counters separately at 5 Digits
(Visible/Invisible),
•Mechanical Lock For Control Panel and 4 Digit
changeable PIN CODE,
•Automatic Failure Display,
•Reloading the Factory Default Settings by 1 touch button,
•Easy Programming & Monitoring with LCD display,
•Standard MENU in 4 Languages (English, German, Turkish and Spanish),
•Additional NO/NC Relay Output for peripheral security apparatus as turnstiles,
cameras, recorders etc. during alarming,
•UPS- Uninterrupted Switching Power Supply, 4 Hours operation without mains,
•Modem/RS232 Output, for Remote Data Communication (SCADA SOFTWARE),
•Modern, Contemporary,
Elinno
/Innovative Design,
•Unique Designs & in variety of colours,
•Easy mounting dismounting (15 Min.),
•With the Outdoor Package can be used at outside
(*option),
•Exported to 4 continents.
NOTE: You may reach ThruScan sX Photo Gallery through www.elektral.com.tr website.
11

1.4
ThruScan
sX–i
•International Norms (NILECJ-0601 L1-3 /
IP54/ IEC 348 Class1, in accordance with CE,
Manufactured in a ISO 9001-2000 certified ),
•MULTIZONE, 9 Real Detection Zone,
•Auto Calibration,
•VLF Technology- human friendly certified
•Green/Red Bicolour Traffic Through LEDs,
•LED Illuminated Warnings at the Control and
Side Panels,
•25 Sensitivity Levels, 246 adjustable levels
at each, applicable to all zones separately
(Program 1 fixed to NILECJ -NC) (jailhouse
sensitivity),
•Separate Zone Sensitivity Settings,
•Automatic Sensitivity Program selects the
correct sensitivity for a specific weapon or
test object-(fast consistent calibration)
“SMART DETECTOR”,
•Graphic Zone Display,
•Display of Metal Density at 10 level
(green/yellow/red) VU meter,
•Environment Magnetic Noise Level Display,
•10 different and 10 level adjustable warning
tones,
•Alarm Counter,
•In & Outgoing Counters separately at 5
Digits (Visible/Invisible),
•Mechanical Lock For Control Panel and 4
Digit changeable PIN CODE,
•Automatic Failure Display,
•Adjustable alarming duration (0,5sec-2secs)
•Negligible false alarming by IR pass sensors!
(deletable function, see 4.1.12),
•Reloading the Factory Default Settings by 1
touch button,
•Easy Programming & Monitoring with LCD display,
•Standard MENU in 4 Languages (English, German, Turkish and Spanish),
•Additional NO/NC Relay Output for peripheral security apparatus as turnstiles,
cameras, recorders etc. during alarming,
•UPS- Uninterrupted Switching Power Supply, 4 Hours operation without mains,
•Modem/RS232 Output, for Remote Data Communication (SCADA SOFTWARE),
•With/Without Cable connection tandem operation of multiple WTMDs,
•Unique Designs & in variety of colours,
•Modern, Contemporary,
Elinno
/Innovative Design,
•Easy mounting / dismounting (15 Min.),
•With the Outdoor Package can be used at outside
(*option),
•Exported to 4 continents.
NOTE: You may reach ThruScan sX Photo Gallery through www.elektral.com.tr website
12

1.5
ThruScan
sX-WP ( Weatherproof Version)
ThruScan
sX-WP has the same superior features as sX even improved in
weatherproofing & some other electronic features.
•International Norms (NILECJ-0601 L1-3 / IP55/
IEC 348 Class1, in accordance with CE,
Manufactured in a ISO 9001-2000 certified ),
•IP 55 – For Outdoor Usage,
•MULTIZONE, 9 Real Detection Zone,
•Auto Calibration,
•VLF Technology- human friendly certified,
•Green/Red Bicolour Traffic Through LEDs,
•LED Illuminated Warnings at the Control and Side
Panels,
•20 Sensitivity Levels, -246 adjustable levels at
each, applicable to all zones separately, 5 fixed
International Sensitivity Standard (optional),
•Separate Zone Sensitivity Settings,
•Automatic Sensitivity Program selects the correct
sensitivity for a specific weapon or test object-
(fast consistent calibration) “SMART DETECTOR”
•Graphic Zone Display,
•Display of Metal Density at 10 level
(green/yellow/red) VU meter,
•Environment Magnetic Noise Level Detection
Display,
•10 different and 10 level adjustable warning
tones,
•Alarm Counter,
•In & Outgoing Counters separately at 5 Digits
(Visible/Invisible),
•Lock For Control Panel and 4 Digit changeable PIN CODE,
•Automatic Failure Display,
•Reloading the Factory Default Settings by 1 touch button,
•Easy Programming & Monitoring with LCD display,
•Standard MENU in 4 Languages (English, German, Turkish and Spanish),
•Additional NO/NC Relay Output for peripheral security apparatus as turnstiles,
cameras, recorders etc. during alarming,
•UPS- Uninterrupted Power Supply, 4 Hours operation without mains,
•Modem/RS232 Output, for Remote Data Communication (SCADA SOFTWARE),
•With/Without Cable connection tandem operation of multiple WTMDs,
•DC Power Supply (Switching Power Pack),
•Unique Designs & in variety of colours,
•Modern, Contemporary,
Elinno
/Innovative Design,
•Easy mounting /dismounting (15 Min.),
•Exported to 4 continents.
NOTE: You may reach ThruScan sX WP Photo Gallery through www.elektral.com.tr website.
13

2 INSTALLATION
2.1 SITE SELECTION
Before choosing a site for
ThruScan
, it is important to consider the volume and throughput of
pedestrian traffic, space availability and overall environmental conditions.
Position and fix
ThruScan
on a flat, stable floor where it remains unaffected by the sun, rain, mist
or condensation. If WTMD will be used for a short time in outdoor then use “Rain Protect Shelter
(Hat)” as well as outdoor package. (See Section 7.2). ThruScan sX-WP is produced for outdoor
fulfilling IP55 standards.
To avoid external metal interference, ensure that there are no large metal items near
ThruScan
.
False alarms may be caused nearby the moving metallic such as an escalator or a revolving door as
well as due to an electrical interference from radio, telephones, television monitors, powerful
electronic motors and transformers.
Do the electrical installation of the WTMD preferably from the ceiling or from the floor (without
moving or stepping on it).
Protect your WTMD from humidity and water since it is versatile electronic equipment.
There is a very sensitive magnetic zone in the passing section of the WTMD. This magnetic zone
can easily be affected by shaking. Protect your
ThruScan
from such unstable situations.
2.2
ASSEMBLING & MOUNTING
2.2.1 Verify that the following contents are included:
9Left hand side panel
9Right hand side panel
9Main control & display unit
9Back fixing crosspiece
9Mains power lead
9Synchronization connection cable
96 base fixing screws
98 panel fixing bolts
98 finishing bolt covers
9Installation spanner (for panel fixing bolts)
Main Control & Display
Unit
Right
Side
Panel
Back fixing
crosspiece
Left
Side
Panel
9Allen key (for base plate)
9User’s manual
2.2.2 Arrange the major components as shown.
2.2.3 Lay the main Control Unit
(with the control panel facing down)
onto a soft, scratch free
surface
(the packing (bubbled pe) is ideal)
.
14

2.2.4 Remove the rear panel of the main Control Unit by undoing the three small fixing screws
(Note: be careful to retain these screws to screw back later)
.
2.2.5 Screw two side panels to “Control Unit” by 2 M10x45 screws. (do not tighten hard).
2.2.6 Plug in the side panel connectors (male-female) to the main Control Units (female-male) as
follows:
•Left side-panel (female/DSUB25) – Plug in to the connector of the Control Unit
(male/DSUB25) and so plug in the other connector(male/DSUB9) to its counterpart on
Control Unit,
•Right side-panel (male/DSUB25) – Plug in to the connector of the Control Unit
(female/DSUB25).
•Connect the mains connector(AC 012) of the side-panel to its socket on the supply module.
Note: This WTMD is designed to prevent false connector/socket connection.
2.2.7 Replace the rear panel of the main Control Unit using the three small fixing screws previously
removed
(see 2.2.4 above)
.
2.2.8 Attach the back fixing crosspiece using the four remaining panel fixing bolts; do not fully
tighten at this stage.
2.2.9 Remove the four hex bolts holding the base fixing plate at the bottom of each side panel
using Allen key.
(Note: be careful to retain the hex bolts in a safe place for replacement later.)
2.2.10 Use two or more people to lift your WTMD carefully to a vertical position and move to
desired location. Ensure the two side panels are perfectly aligned parallel to each other with 76cm
spacing between panels.
CAUTION! The WTMD will not operate correctly if the side panels and the infrared
sensors are not properly paralleled.
2.2.11 Use two or more people to lift the WTMD to a vertical position and place on to the base
fixing plates ensuring the gateway is correctly orientated for the direction of the required
pedestrian traffic. Place the side panels to the base fixing plates, using Allen key
(see 2.2.9 above).
Tighten only to prevent moving; DO NOT over tighten.
2.2.12 Ensure that
ThruScan
is physically stable.
2.2.13 Fully tighten all bolts with the installation spanner.
2.2.14 Finally, ensure that the power cable is protected from pedestrian and vehicular traffic and
connect the power cable to the well grounded mains.
15

3. CONTROL (DISPLAY) PANEL & INDICATION INFORMATION
The control panel functions are protected from unauthorized tampering by a lockable
see through control cover in the overhead main Control Unit. Operators should not
normally need to adjust these controls, which should only be altered by a supervisor or manager in
order to change the sensitivity settings of
ThruScan
, reset counters, perform installation
adjustments and to switch the unit on /off etc.
3.1 CONTROL PANEL
The control display panel provides a visual indication of the status of the unit as well as all controls
necessary for the programming and operation of the unit. The following features can be found on
the display panel.
Note that the display Panel is the same for all
ThruScan
s
ON-OFF BUTTON IRDA REMOTE CONTROL RECEIVER UPS INDICATOR
VU DISPLAY
TRAFFIC LIGHTS
INDICATOR
LCD DISPLAY
(screen)
RUN(X) SEL(√) UP DOWN GRAFIC ZONE LEDs (LOCATOR)
3.1.1 LCD (LIQUID CRYSTAL DISPLAY-SCREEN)
The LCD is an ongoing visual display located in the overhead Control Unit. The LCD displays the
security level settings and traffic count of both incoming and outgoing traffic. The display also
provides operational information, including program settings and adjustment information together
with fault indication and alarm displays.
3.1.2 GRAFIC (ALARM) ZONE LEDs (LOCATOR)
The display panel gives a graphical indication of the area of any alarm
activation by indicating whether the point of detection is on the right, left
or centre of the body and also whether it is at a high, middle or low level.
3.1.3 VU DISPLAY (led array)
The LED VU comprises of five green, three yellow and three red LED’s providing a
graphical indication of the level of metal detection activity occurring within the
archway. The degree of detection intensity varies depending on the quantity and
composition of the metallic object(s).
16

Note: WTMD and thus the VU display will only operate whilst the infrared beam is
obstructed.
CAUTION! the first (green) led only indicate that the WTMD is on but not any
operational detection situation.
3.1.4 UPS INDICATOR
If the battery voltage drops below 10.5 volts dc the indicator will begin to
flash; if the battery voltage drops to 9.5 volts dc the indicator will continue
flashing and an intermittent alarm tone will start – if the power is not
restored the WTMD will then automatically shuts itself.
3.1.5 IRDA REMOTE CONTROL RECEIVER
(*only for ThruScan sX/sX-i)
It is the receiving LED of the pilot Remote Control Unit.
3.1.6 TRAFFIC LIGHTS
The traffic lights will mimic the passage is free and possible. – Green indicates walk –
Red indicates wait.
3.2
TOUCHPADS
A total of five touchpad controls are located on the control unit as follows;
3.2.1 ON - OFF BUTTON
The ON-OFF touchpad button turns on and off the WTMD. When first switched on the
WTMD initiates a self-test for ten seconds during which time a ‘test tone’ will be heard.
Please wait for 1 minute after switching on before using the gateway in order to allow
the auto-calibration program to designate/memorize for metal objects around its
environment.
The previous settings and adjustments would be stored when you turn off your
WTMD and will be displayed when on again.
3.2.2 RUN(X) BUTTON
The RUN(X) touchpad button returns the WTMD to RUN(X)/operation mode after
any programming changes are made using the SEL(√) button. It is also used as an
“ESC” button when no changes are made.
3.2.3 SEL(√) BUTTON
The SEL(ect) touchpad button is for to access and enter the programming modes
and to confirm programming changes. It serves as an “ESC” button.
3.2.4 UP&DOWN BUTTONS
The UP&DOWN touchpad buttons moves up and down through the
programming options when on the MENU thus the programming mode. These
buttons is called UP&DOWN Buttons afterwards.
17

3.3
TRAFFIC LIGHTS
Traffic lights are located at the entrance of the side panels on both panels.
These bi-color lights indicate if the archway is ready to control for passage.
•The green light indicates “Walk”.
•The red light indicates “Wait”.
*This performance is achieved by a bi-color lamp under Control Unit at model ThruScan
s3.
3.4
ZONE(INDICATOR)- LIGHTS (*)
Zone (Indicator) Lights comprise by 2x6 distinct pinpoint light-
arrays and are located on the side panels of the exit side of
the WTMD. These lights indicate to identify the precise
location of a metal object within the WTMD archway whether
it is on the right, centre, left and/or top, middle, bottom of
the body(3 sides/3 levels).
(*) ThruScan s3 do not have this feature but Graphic
Zone Leds on control panel.
WARNING: In case of a power cut, ThruScan continues
operation with its internal power supply. Zone-lights
will shut down automatically to save energy after a
certain period of time during power failure. Graphic
Display on Control Panel will indicate the location of
threat zone.
3.5
VARIOUS ALARMS
Both the supervisor and the operator should be familiar with
the
ThruScan
’s audio & visual alarms.
The unit will generate an alarm condition to indicate that a
sufficient volume of metal (according to the program and
sensitivity settings) has been detected; Special built-in filtering
circuits help to suppress excess electronic noise signals from a
variety of sources, including X-ray monitors, horizontal synchronisation and closed-circuit
television/CCTV, etc..
Metal detectors sometimes generate false alarms, triggered by nearby metal objects or interference
from electrical or mechanical environmental noise from large motors, computers, fluorescent
lighting or other sources. The
ThruScan
’s infrared sensors are a feature that helps to minimise the
audible false alarms by ensuring that an alarm activates only if a person passes through the
archway.
A false source may trigger the alarm rarely such as a person pass and bump the archway also.
18

CAUTION! The operator must never dismiss a false alarm since there may be the
possibility of a professional terrorist person to create a false alarm by bumping and
thus creating confusion.
3.6 RELAY CONTACT OUTPUTS (RJ11/12)
Relay contacts are present on
ThruScan
(on the side panel as a socket output) as
phone connector. The outputs; normally open(NO) and normally closed(NOFF) are
activated by alarms. This feature provides to control and use of peripheral equipment
such as CCTV, Camera, Turnstiles, Gates, etc. .
CONTACTS/PINS*** ((RJ11/12) 220 VAC/0.5 Amps ~ 24 VDC/2 Amps.)
1- NO
2- NO
3- Common
4- Common
5- NC
6- NC
*** Contact numbers of the socket are coded as they appear on the picture/WTMD from left to
right.
3.7 SYNCHORNIZATION AND REMOTE CONTROL OUTPUTS (RJ11/12)
This socket (for phone connector)*** is for two or more WTMDs to be used in tandem
and/or for remote control by using the direct cable or a modem via phone line. See
Section 6.13 and Section 7.1
1- Transmitter1
2- Transmitter2
5- Ground/Earth (Norm)
6- RS 232
*** Contact numbers of the socket are coded as they appear on the WTMD from left to right.
19