1. Switch off the main circuit breaker.
2. Connect the receiver according to the diagram.
3. Switch on the main circuit breaker; the green diode is
flashing on the receiver; the receiver is ready for
further setting.
4. Shortly press the FUNCTION BUTTON for about 1.5 s
(the green and red diode are flashing alternately).
5. Activate the receiver on the thermostat (transmitter)
according to the manual for the given transmitter (BPT010
or BPT710).
6. If the code has been learned correctly, the green and
red diodes flash simultaneously.
LED 2
LED 1
empty memory, code not learned
code learned
FLASHING ALTERNATELY = code learning mode
FLASHING SIMULTANEOUSLY = code has been learned
SIMULTANEOUS LONG FLASH= code has been ERASED
relay switched
ERROR (if no signal is received from the transmit-
ter within approx. 6 hours, it switches to the 2-min-
ON / 8-min-OFF mode). LED 2 is only flashing if
the relay is on, i.e. for 2 minutes.
EXPLANATIONS: LIT UNLIT FLASHING
FUNCTION
ACTIVATION PROCEDURE
INDICATION DIODES