DESCRIPTION OF CONTROL ELEMENTS
START UP PROCEDURE IN THE PocketHome®SYSTEM
- check correct of receiver connection to boiler and el. network
- push briefly FUNCTION SWITCH for ca 1s (yellow and red LED blinking
intermittently)
- press” Test ” in ACTIVE regime for receiver on the central unit
(see instructions for PH-CJ37)
- for correct code learning yellow and red LED blink simultaneously
- during 1min. the receiver is activated in the PocketHome®system and
is priority-controlled from the PH-CJ37 central unit!
output
for boiler
el. supply
230 V/50 Hz
FUNCTION
SWITCH
Indication LED's:
GREEN LIT UP
- correct connection to el. network
ORANGE LIT UP
- relay switched on
YELLOW
YELLOW BLINKING
- sending or receiving signal
RED BLINKING
- empty E-EPROM memory
RED LIT UP
- FAILURE (if no signal is received in ca 6 hours
from the transmitter, will witch to 2 min. ON and
8 min. OFF regime)
YELLOW
YELLOW+RED BLINKING ALTERNATELY
- code determination regime
YELLOW
YELLOW+RED BLINKING CONCURRENTLY
- code was learnt
MOUNTING
We recommend that the installation should be carried out by person with
a relevant electro-technician's qualification!
- turn off main switch
- connect according to chart (use clips for room thermostat -
2 wires)
- connect receiver to 230V/50Hz el. network
- turn on main switch and green LED will light up – receiver ready
for further setting
Before receiver activation it is necessary to have the central unit set and ready
according to instructions for PH-CJ37!
1. RECEIVER ACTIVATION -ESTABLISHING COMMUNICATION WITH THE CENTRAL UNIT
If communication is not successfully established:
- press FUNCTION BUTTON for 5s to delete E-EPROM memory
(RESET) (all LED's are lit up and after 2s only red light start to blink =
empty memory)
- repeat the whole code-learning procedure
Switch function:
AUT - works according to programme
ZAP - switched on permanently
VYP - switched off permanently
through-socket for
another el.
consumer connection
BOILER
ph_pk21_en:Layout 1 18.5.2011 21:24 Page 2