Background parameter settings
Press and hold the top “sel” key, then turn on the ignition switch. After 5 seconds, it will enter the settings, divided into six pages.
Page 1: Setting of tyre circumference
C-1850 means the default tyre circumference is 1850 mm. Short presses of the top “sel”button changes each digit. Press the bottom “set”
button to move to the next digit. The circumference can be set from 500 to 2600 mm. Press the top “sel”key for 3 seconds to save the
circumference and enter the next page.
Page 2: Magnets Number Setting
C – 02 means there are two magnets, 1 - 12 can be set. Short presses of the top “sel”button changes each digit.
Press the top “sel”key for 3 seconds to save the number of magnets and enter the next page.
Page 3: Speed setting interface
C-2, 2 indicates that the engine is 2 cylinders. (166HZ) Switch 2/4 cylinders by pressing the top “sel”key. Press the button for 3 seconds to save
it into the two-wire and three-wire fuel setting interface. ,
Page 4: Fuel setting of two lines and three lines (two lines and three lines should be set in the general term of upper computer)
The 188 first 8-word speed display shows 4, the total cumulative display E-3, 3 for the three-line oil meter, 3 for the three-line display E-3, 2 for
the two-line display E-2, and 3/2 for the switch by pressing the button. Press the button for 3 seconds to save and enter the accumulated clearing
interface.
Page 5: Changing the speed between mph and kmh
Short presses of the top “sel”button changes between mph and kph.
Press the top “sel”key for 3 seconds to save the speed setting and enter the next page.
Page 6: Resetting the total mileage.
The total mileage can be reset to zero in this page.