HARDWARE GUIDE
Scan the code to visit the Alarm Engine Knowledge
Center for setup videos and detailed instructions.
Printed In USA
L691 5/19/2023
PO Box 100 3266 US Hwy 70 West
Hildebran, NC 28637
Phone 828-397-4200 https://www.elkproducts.com
LIMITED WARRANTY
The E27 Alarm Engine (ELK-E27CB) is warranted to be free from defects and workmanship for a period of 2 years from date of
manufacture. Elk makes no warranty, express or implied, including that of merchantability or tness for any particular purpose with
regard to batteries used with wireless devices. Refer to Elk’s website for full warranty statement and details.
E27 Alarm Engine®
About This Guide
This quick start guide will provide a basic overview of the E27 Alarm Engine hardware. Please refer to the E27
Knowledge Center for detailed installation instructions.
Specifications
• Input capacity: 128 Total, hardwired, wireless or hybrid; 16 hardwired on-board zones
• Supports up to 3 two-wire smoke detector zones
• On-Board Outputs: 2 Alarm speaker outputs, 1 Form “C” Relay, and 10 Voltage Outputs (12VDC, 50 mA)
• Partitions: Up to 8
• User Codes: Up to 199 with assignable authority levels
• Maximum Keypads allowed: 8
• 2.5 Amp power supply with master cuto switch and low battery cuto
Getting Started
Before proceeding with product installation, please review the checklist below:
Do you have an account/login for the ElkConnect cloud portal?
• E27 controls must be registered and assigned through the ELK Connect cloud portal. You must complete the ELK Connect
account application to setup your account.
Have you downloaded the ElkConnect App?
• The ELK Connect app is used to configure the E27 control. The app is availalble for Android and iOS devices.
Search app store for ElkConnect
Wiring & Hookup Overview
Refer to the E27 Board Layout Diagram in this guide.
• Connect sensors to hardwired zone inputs. Default zone configuration requires 2.2K Ohm EOL resistors. For sensors that
require power (motion detectors, etc.), use VAUX auxiliary power terminals (observe polarity).
• The E27 control must be connected to a Wi-Fi enabled network to connect with ElkConnect app. There are three
methods to connect E27 to the LAN:
• Connect Ethernet port to Wi-Fi enabled router/switch using standard network patch cable.
• Connect Wi-Fi adapter to E27 board and use Wi-Fi Access Point Mode to configure E27 to connect to client’s Wi-Fi network.
• Connect Wi-Fi adapter to E27 board and use WPS to connect to client’s Wi-Fi Network.
• If desired, connect interior speaker negative to ALRM 1 and speaker positive to +12V ALRM.
• Connect standby battery to battery leads (observe polarity).
• Connect 14 VDC power supply to DC input terminals (observe polarity).
• Turn E27 on using master power switch. Status display should display A. followed by IP address. Aer displaying IP
address, display should show E.no (no errors). If any error codes are displayed, power down and refer to E27 Knowledge
Center for troubleshooting guidelines.
Before making any connections,
TURN THE E27 MASTER POWER SWITCH OFF.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
Changes or modifications not expressly approved by the party responsible for compli-
ance could void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or tele-
vision reception, which can be determined by turning the equipment o and on, the user
is encouraged to try to correct the interference by one of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innova-
tion, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is
subject to the following two conditions:
• This device may not cause interference.
• This device must accept any interference, including interference that may cause unde-
sired operation of the device
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme
aux CNR d’Innovation, Sciences et Développement économique Canada applicables
aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions
suivantes :
• L’appareil ne doit pas produire de brouillage;
• L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
CAN ICES-3 (B)/NMB-3(B)
FCC AND IC COMPLIANCE STATEMENT:
PWR
WIFI
Option
ZWAVE
Option ETHERNET
JP5 JP6 JP7
2W NORM
2W NORM
Z14 Z15 Z16
Z1
Z2
Z3
Z5
Z7
Z6
Z4
Z8
Z9
Z10
Z11
Z13
Z15
Z14
Z12
Z16
NEG
NEG
NEG
NEG
NEG
NEG
NEG
NEG
+VAUX
+SAUX
NEG
NEG
+BUS
12V
BUSB
BUSA
NEG
NEG
‐BAT
BLK
+14V
DCIN
+BAT
RED
N/C
N/O
COM
ALM2
ALM1
+ALM
OPTIONALWIRELESSRECEIVER
CONFIGSW
J16OUTPUTS
4 Wire
Data Bus
12V Lead Acid
Battery
15
N.C. N.O.
ZONE
2200
Ohm
EOL 16
N.C. N.O.
ZONE
2200
Ohm
EOL
13
N.C. N.O.
ZONE
2200
Ohm
EOL 14
N.C. N.O.
ZONE
2200
Ohm
EOL
11
N.C. N.O.
ZONE
2200
Ohm
EOL 12
N.C. N.O.
ZONE
2200
Ohm
EOL
9
N.C. N.O.
ZONE
2200
Ohm
EOL 10
N.C. N.O.
ZONE
2200
Ohm
EOL
7
N.C. N.O.
ZONE
2200
Ohm
EOL 8
N.C. N.O.
ZONE
2200
Ohm
EOL
5
N.C. N.O.
ZONE
2200
Ohm
EOL 6
N.C. N.O.
ZONE
2200
Ohm
EOL
3
N.C. N.O.
ZONE
2200
Ohm
EOL 4
N.C. N.O.
ZONE
2200
Ohm
EOL
1
N.C. N.O.
ZONE
2200
Ohm
EOL 2
N.C. N.O.
ZONE
2200
Ohm
EOL
ALM2
ALM1
+
‐
+
‐
Output11–ProgrammableGeneralPurposeRelay
Ratedat4Amps@12‐24VDC(DryContacts)
10
9
8
7
6
5
4
3
2
1
+12V
Neg
J16–ProgrammableOutputs1‐10
12VDCswitchedpositivegeneralpurposeoutputsratedat50mA
SupervisedALARMOutputs
Forspeakersonly(4to8ohms)
Ifnotused,installa2.2KOhmresistor
toavoidAlarmOutputTrouble.
NOTE:DonotplaceaDirectShort
acrossAlarmoutputterminals.
RS‐485DataBus
Forconnectionofperipheraldevices
includingkeypads,expanders,etc.
Totallengthof2homerunsmustnot
exceed4000ft.
14VDCPowerSupply–ELK‐P1426
DONOTCONNECTTOACTRANSFORMER!
DONOTCONNECTTOSWITCHEDOUTLET
ObservePolarity.18AWGMinimum.
StandbyBattery
Replacebatteryevery3‐5years.UseELK‐1280
(12V8Ah)orELK‐12180(12V18Ah)or
equivalent.
MasterPowerSwitch
DisconnectsDCpowersupplyandstandbybatteryfromcontrol.
Status/DiagnosticDisplay
Normalstatusdisplayis
Displayserrorcodesandotherdiagnosticinformation.Formore
information,pleaserefertoE27productmanual.
EthernetPort
ProvideshardwiredconnectiontoLAN/
Internet.Usestandardnetworkpatch
cabletonetworkrouterorswitch.
ConnectorforOptionalZ‐WaveModule
Formoreinformation,pleaserefertoinstallationinstructionsforthe
ELK‐AEZWZ‐WaveModule.
ConnectorforOptionalWi‐FiAdapter
Formoreinformation,pleaserefertoinstallationinstructionsforthe
ELK‐AEWFWi‐FiAdapter.
Router/Switch
820
Ohm
EOL
NEG
Z14,Z15,orZ16
2‐WIRESMOKEDETECTOR
Pleaserefertoknowledgecenterforalistof
compatible2‐wiresmokedetectorsand
additionaldetails.
JumpersJP5,JP6,JP7
Toconfigurezone14,15,or16for2wiresmoke
detectors,setcorrespondingjumperto2W
Auxiliary
12VDCPowerOutput
1.25AmpPTCProtected
SwitchedAuxiliary
12VDCPowerOutput
1.25AmpPTCProtected
4‐WIRESMOKEDETECTOR
ULListedEOLSupervisionRelay
Red(2)
Red(2)
Red(2x0)
Gold(quality)
ColorCodefor2200
OhmEOLResistor
(ELK‐ER2200)
Gray(8)
Red(2)
Brown(1x0)
Gold(quality)
ColorCodefor820
OhmEOLResistor
(ELK‐ER820)
CLOCK
BATTERY
SDMEMORY
CARDSLOT
3VLithiumClockBattery(CR2032)
Batteryhasalifeexpectancyof10years.Replaceonlywith
exactmodelavailableatmostelectronicsandcameraretailers.
CAUTION:LithiumBatteryMayExplodeIfMistreated.DoNot
Recharge,Disassemble,orDisposeOfInFire.
SlotforOptionalSDMemoryCard
Providesadditionalstorageforeventlogdata.
SDmemorycardsareavailablefrommost
electronicsandcameraretailers.
ConfigurationSwitch
Fordetailsonfunctionsoftheconfiguration
switch,pleaserefertotheE27productmanual.
OptionalWirelessModule
Fordetailsonsupportedmodulesandinstallation,pleaserefertoknowledgecenter.
JP1
J6
JP1–TerminatingJumperforRS‐485DataBus
J6–TemporaryConnection“Plug‐inJacks”forRS‐485DataBus
Localconnectionfordatabusdevices(keypad,expander,etc.)for
testingpurposesonly
Output11(Relay)LEDIndicator
EthernetLEDIndicator
CloudConnectionLEDIndicator(WiredorWi‐Fi)
ON
SmokeDetectorcoversshouldbekeptfreefrom
dustanddirtbyuseofadryordamp(water)
clothasneeded.Whennecessary,cleanthe
detectorinteriorand/orreplacetheoptical
chamberaccordingtoinstructionsprovidedby
theSmokeDetectorManufacturer.
2200
Ohm
EOL
AnyZone
Input
N.O.AlarmContacts
+
‐
+SAUX
Zone
NEG
NEG
E27 Board Layout Diagram
Testing of this system should be
performed regularly with the
primary DC power de-energized.
Control panel specifications are
subject to change without notice.

Other Elk Products Control Unit manuals

Elk Products ELK-120 User manual

Elk Products

Elk Products ELK-120 User manual

Elk Products Magic Module Series User manual

Elk Products

Elk Products Magic Module Series User manual

Elk Products ELK-PD9 User manual

Elk Products

Elk Products ELK-PD9 User manual

Elk Products ELK-100 User manual

Elk Products

Elk Products ELK-100 User manual

Elk Products ELK-110 User manual

Elk Products

Elk Products ELK-110 User manual

Popular Control Unit manuals by other brands

Rockwell Automation Trusted T8834 manual

Rockwell Automation

Rockwell Automation Trusted T8834 manual

Runxin F56A instruction manual

Runxin

Runxin F56A instruction manual

Siemens SIMATIC ET 200SP manual

Siemens

Siemens SIMATIC ET 200SP manual

WP MXMA 4800 Workshop manual

WP

WP MXMA 4800 Workshop manual

Bitzer CM-RC-01 Maintenance instructions

Bitzer

Bitzer CM-RC-01 Maintenance instructions

Parker Racor 200 Series installation instructions

Parker

Parker Racor 200 Series installation instructions

Pickering 40-582 user manual

Pickering

Pickering 40-582 user manual

Royal Enfield M2d product manual

Royal Enfield

Royal Enfield M2d product manual

Samson 42-36 E Mounting and operating instructions

Samson

Samson 42-36 E Mounting and operating instructions

Siemens ASR61EX Mounting instructions

Siemens

Siemens ASR61EX Mounting instructions

GEA VARIVENT K Operating	 instruction

GEA

GEA VARIVENT K Operating instruction

Siemens SINUMERIK 802D sl instruction manual

Siemens

Siemens SINUMERIK 802D sl instruction manual

Samson BR14b operating instructions

Samson

Samson BR14b operating instructions

Samson Valve Series Mounting and operating instructions

Samson

Samson Valve Series Mounting and operating instructions

Compac C4000 Futra manual

Compac

Compac C4000 Futra manual

Texas Instruments DRV10964 user guide

Texas Instruments

Texas Instruments DRV10964 user guide

Mutable Instruments Edges manual

Mutable Instruments

Mutable Instruments Edges manual

AXIOMTEK CEM312 Quick installation guide

AXIOMTEK

AXIOMTEK CEM312 Quick installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.