manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Elk Products
  6. •
  7. Power Supply
  8. •
  9. Elk Products ELK-P1224 Assembly instructions

Elk Products ELK-P1224 Assembly instructions

This manual suits for next models

2

Other Elk Products Power Supply manuals

Elk Products 982 User manual

Elk Products

Elk Products 982 User manual

Elk Products ELK-P412 Owner's manual

Elk Products

Elk Products ELK-P412 Owner's manual

Elk Products ELK-981 User manual

Elk Products

Elk Products ELK-981 User manual

Elk Products ELK-P112 User manual

Elk Products

Elk Products ELK-P112 User manual

Elk Products ELK-P412 User manual

Elk Products

Elk Products ELK-P412 User manual

Elk Products ELK-P624 User manual

Elk Products

Elk Products ELK-P624 User manual

Elk Products ELK-P412 User manual

Elk Products

Elk Products ELK-P412 User manual

Popular Power Supply manuals by other brands

Videx 520MR Installation instruction

Videx

Videx 520MR Installation instruction

Poppstar 1008821 Instructions for use

Poppstar

Poppstar 1008821 Instructions for use

TDK-Lambda LZS-A1000-3 Installation, operation and maintenance manual

TDK-Lambda

TDK-Lambda LZS-A1000-3 Installation, operation and maintenance manual

TDK-Lambda 500A instruction manual

TDK-Lambda

TDK-Lambda 500A instruction manual

Calira EVS 17/07-DS/IU operating instructions

Calira

Calira EVS 17/07-DS/IU operating instructions

Monacor PS-12CCD instruction manual

Monacor

Monacor PS-12CCD instruction manual

VOLTIMA MagicBox 15 Installation and operating instructions

VOLTIMA

VOLTIMA MagicBox 15 Installation and operating instructions

Miller Auto Deltaweld 452 owner's manual

Miller

Miller Auto Deltaweld 452 owner's manual

BCP PUOUBK How to install

BCP

BCP PUOUBK How to install

HC 2210 manual

HC

HC 2210 manual

Agilent Technologies 6032A Service manual

Agilent Technologies

Agilent Technologies 6032A Service manual

Radial Engineering SB-48UB user guide

Radial Engineering

Radial Engineering SB-48UB user guide

Puls CT5.241 installation manual

Puls

Puls CT5.241 installation manual

OCZ ZX1250W Technical specifications

OCZ

OCZ ZX1250W Technical specifications

iseg ECH 238 manual

iseg

iseg ECH 238 manual

Agilent Technologies 6631B Service manual

Agilent Technologies

Agilent Technologies 6631B Service manual

Power XXL A Series instruction manual

Power

Power XXL A Series instruction manual

HP 6200B Operating and service manual

HP

HP 6200B Operating and service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ELK-P1224 Installation Manual Page 1
ELK-P1224
Power Supply /
Battery Charger Kit
For the latest downloadable version of this manual, visit our website: http://www.elkproducts.com
Installation and Setup Guide
APPLICATION
The ELK-P1224 Power Supply/Battery Charger Kit is a plug-in14VDC
Power Supply (ELK-P1426) combined with an intelligent Charger
Board (ELK-P1224CB). It can supply up to 2.4 Amps of current
at 12VDC (nominal). The charger board features a Low Battery
Supervision output, Low Battery Cuto, as well as a Manual On/
O switch. The Power Supply features built-in overload reset and
screw terminals for connections.
SPECIFICATIONS
ELK-P1426
Plug-in power supply with receptacle mounting bracket
• Input Voltage Range: 100 - 240 Volts AC, 50/60Hz
• Input Current: 0.8 Amps AC
• Output Voltage Range: 13.8 to 14 Volts DC.
• Continuous Output Current: 2.6 Amps DC
• Complies with UL 60950
• Compliant with Energy Star EISA Level V
• RoHS compliant (RoHS2-2011/65/EU)
• Size w/ mounting bracket: 3.07" x 2.83" x 1.5" (78 x 72 x 38 mm)
• AC input plug style: NEMA 1-15P (non-polarized)
• Positive and Negative screw terminals on DC output
ELK-P1224CB
• Power Supply Input: 14 Volts DC provided by ELK-P1426
• Continuous Output Current: 2.4 Amps. **
• Low Battery Trouble: 11 Volts. (nominal)
• Low Battery Cuto: 9 Volts. (nominal)
• PC Board Size: 2.25" X 2.5" (57.15mm X 63.5mm )
• Standby Battery Charging Capacity: 1 to 12 Ah, Sealed Lead Acid
• Battery Wire Length: 16" with F1-Faston No. 187 Receptacles
• Master Power Switch turns On/O the DC Input and Battery
• Operating Temp: 32° to +120° degrees F
• Humidity: 95% RH (max.), non-condensing
** Higher output current (up to 2.5 Amps) may be drawn for a short
time provided a fully charged battery is connected.
AVAILABLE PART NUMBERS/CONTENTS
ELK-P1224 Power Supply/Charger Kit (pictured above)
ELK-P1426 Plug-in Power Supply
ELK-P1224CB Circuit Board
ELK-P1426 Plug-in Power Supply ONLY, 14VDC @ 2.6A
ELK-P1224
Features or Specications subject to change without notice.
800-797-9355
www.elkproducts.com
email: [email protected]
PO Box 100 • Hildebran, NC 28637 • USA
FEATURES
• Auto-Resetting Overload Protection
• Built-In Battery Charging Circuit
• Low Battery Trouble Output
• Low Battery Deep Discharge Cuto Protection
• Master Power Switch
• Lifetime Limited Warranty
ELK-P1426 ELK-P1224CB
Page 2 ELK-P1224 Installation Manual
DC Output
12 Volts at 2.4 Amps
Maximum
+-
ON
OFF
M A ST ER
SW I TC H
12V SLA
BA T TE R Y
ELK-P1224CB
12V DC CHARGER BD W/SU PV + CUTOFF
MAX. 2.4A
Master Power Switch
Turns On/Off the DC
Inputand Battery
+-
Battery Wires to
Sealed Lead Acid
Standby Battery
(+) Red (-) Black
E LK -P1426
NEG+NEG
12V DC O U T
+
-
SU P
+
-
-
+
LED (D4) is used as circuitry
voltage reference only and is not
intended as a user in dicator
D4
Plugs
into
120 VAC
Note:
Ou tput Vol tage from ELK-P1426 is
13.8 t o 14 volts DC to properly
charge the batte ry.
18AW G mi n.,
10' m ax length.
-
DC Input
DC Power Supply
ELK-P1426
F1-Faston No. 187 Receptacles
Low Battery Supervision
Open Drain Output that pulls to
ground when active.
(100mA max)
Hookup to a Security Zone.
End of Line supervised zone using 2200 ohm End of Line Resistor
or
Remove the EOL resistor if using un-supervised “norma lly op en” zo ne .
ELK-P
12V DC
E LK -P1426
NEG+NEG
12V DC O U T
+
-
SU P
-NEG
Zone Input
Security Control
2200
EOL
ELK-P
12V DC
E LK -P1426
NEG+NEG
12V DC O U T
+
-
SU P
-
12 Volts DC So un der
-+
+
LED w/ required
1000 Oh m Res ist or
1000
LE D wi th a 1000 ohm resistor or 12 Volts DC Sounder.
Example hookups for alerting a low battery condition
OPERATION
Master Power Switch
This switch allows users to turn On or O all power from the DC Output terminals for servicing.
Battery Supervision
If DC power from the ELK-P1426 is lost (i.e. AC power outage), the battery should continue to supply power to the ELK-P1224CB DC Output
terminals. The battery's voltage is then monitored and if the voltage drops to 11 volts, then the –SUP low battery supervision output will turn ON
(pull to ground) indicating a Low Battery condition.
The -SUP output can be connected to an LED, 12 Volts DC Sounder, or a zone on a Security Control to report a low battery condition.
Note: The –SUP output will only work until Low Battery Cuto activates, (see below) at which time -SUP becomes inactive since all power to the
P1224CB board will be completely shuto.
Low Battery Cuto󰀨
If DC power from the ELK-P1426 continues to be lost for an extended period, the battery should continue to supply power to the ELK-P1224CB
DC Output terminals. The battery's voltage is monitored during this time and if the voltage drops to 9 volts, then the battery will be Cuto
(disconnected) from the DC Output terminals. This helps to prevent “deep discharging” of the battery.
Hookup
1. Observe correct polarity on all connections.
2. The ELK-P1224CB circuit board can be mounted directly on top of a battery. Connect the two battery wires to the battery terminals. Red wire
to positive, Black wire to negative.
3. Connect ONLY the ELK-P1426 Power Pack to the DC Input terminals. DO NOT CONNECT an AC TRANSFORMER.
Two-conductor jacketed cable having Red and Black color coded wires are recommended, minimum 18 AWG. Maintain polarity if using
non-color coded Zip cord. The consequences of using too small of a wire gauge, or extending the wire length beyond the recommended
lengths may harm the ability to properly charge the battery, especially at full DC Output Load.
If using 18AWG - Do NOT exceed a distance of 10 feet.
If using 16AWG - Do NOT exceed a distance of 15 feet.
If using 14AWG - Do NOT exceed a distance of 25 feet.
4. Plug the ELK-P1426 into a constant 120VAC source.
5. Connect the DC Output to the desired load.
6. Turn on Master Power Switch.
Printed in USA L707 2/6/2023