logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Elk Products
  6. •
  7. Power Supply
  8. •
  9. Elk Products ELK-P412 User manual

Elk Products ELK-P412 User manual

Other Elk Products Power Supply manuals

Elk Products ELK-P412 User manual

Elk Products

Elk Products ELK-P412 User manual

Elk Products ELK-P112 User manual

Elk Products

Elk Products ELK-P112 User manual

Elk Products ELK-P624 User manual

Elk Products

Elk Products ELK-P624 User manual

Elk Products 982 User manual

Elk Products

Elk Products 982 User manual

Elk Products ELK-981 User manual

Elk Products

Elk Products ELK-981 User manual

Elk Products ELK-P1224 Assembly instructions

Elk Products

Elk Products ELK-P1224 Assembly instructions

Elk Products ELK-P412 Owner's manual

Elk Products

Elk Products ELK-P412 Owner's manual

Popular Power Supply manuals by other brands

Monacor PS-12CCD instruction manual

Monacor

Monacor PS-12CCD instruction manual

VOLTIMA MagicBox 15 Installation and operating instructions

VOLTIMA

VOLTIMA MagicBox 15 Installation and operating instructions

Miller Auto Deltaweld 452 owner's manual

Miller

Miller Auto Deltaweld 452 owner's manual

BCP PUOUBK How to install

BCP

BCP PUOUBK How to install

HC 2210 manual

HC

HC 2210 manual

Agilent Technologies 6032A Service manual

Agilent Technologies

Agilent Technologies 6032A Service manual

Puls CT5.241 installation manual

Puls

Puls CT5.241 installation manual

OCZ ZX1250W Technical specifications

OCZ

OCZ ZX1250W Technical specifications

iseg ECH 238 manual

iseg

iseg ECH 238 manual

Agilent Technologies 6631B Service manual

Agilent Technologies

Agilent Technologies 6631B Service manual

Power XXL A Series instruction manual

Power

Power XXL A Series instruction manual

Renogy PHOENIX 300 user guide

Renogy

Renogy PHOENIX 300 user guide

HP 6200B Operating and service manual

HP

HP 6200B Operating and service manual

Epson Stylus Scan 2500 Product information sheet

Epson

Epson Stylus Scan 2500 Product information sheet

Pulsar GREEN POWER CCTV PoE POE044816 manual

Pulsar

Pulsar GREEN POWER CCTV PoE POE044816 manual

Puls MiniLine ML50.100 instruction manual

Puls

Puls MiniLine ML50.100 instruction manual

Puls AS-Interface SLA4.100 installation manual

Puls

Puls AS-Interface SLA4.100 installation manual

Kenwood PS-60 instruction manual

Kenwood

Kenwood PS-60 instruction manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

P.O. Box 100 • Hildebran, NC 28637 USA • 828-397-4200 • 828-397-4415 FAX
http://www.elkproducts.com • email: [email protected]
ELK
PRODUCTS, INC.
APPLICATION
The ELK-P412 is a general purpose high current power supply and battery charger. It is ideal for alarm, access
control, and CCTV applications requiring up to 4 Amps. It distributes 12 Volts D.C. power to three (3) sets of DC power
terminals, each having a voltage present indicator LED and automatic resetting overload protection. Built-In Low
Battery Cut-off circuit protects the battery from deep discharging if AC power is lost for an extended period of time.
Power Supply
4 Amp, 12 Volt DC Power Supply &
Battery Charger with Enclosure
12 Volt Battery
(ELK-1270)
(Purchase separately)
AC
INPUT
BLACK
+
-
POWER
ON
POWER ON LEDS
L N -V +V
DC
OUTPUT
EARTH
GROUND
Power Supply
POWER
OFF
SW1
+
-
RED
120 VAC POWER
CORD (6')
Before plugging
in the power
cord, replace the
snap-on cover
over the AC
terminals for
shock protection
LOAD 3
WARNING
SHOCK
HAZARD
LOAD 1
LOAD 2
GRDNEUTRLLINE
NEG +12V
OUTPUT 3
BATTERY
NEG +12VNEG +12V
OUTPUT 2OUTPUT 1
14.5VDC IN
AC
LED
FACTORY SET
DO NOT ADJUST
Power Distribution Module
120 VAC
Input
INSTALLATION / OPERATION
1. Set Master Power Switch (SW1) to Power Off.
2. Mount enclosure in secure location near an AC power
outlet that is not controlled by a switch.(supplied power
cord is 6 feet long)
3. Connect devices to be powered to the screw terminals
for DC output. The power distribution board has three
sets of outputs, each set is limited to 2.5 amps. If a
device requires more that 2.5 Amps, parallel two sets of
terminals. (DO NOT EXCEED 4 AMPS)
4. Connect Battery to the battery wires, observe polarity.
5. Plug in the AC cord. Warning High Voltage is now
present at the power supply AC input terminals.
6. Set the Master Power Switch to Power On. The LEDs at
the power outputs should be on (if any are off, check for
overloaded condition). The connected devices are now
powered.
7. If AC power is lost, the Low Battery circuit will disconnect
the battery if it's voltage drops below 10 Vdc. This helps
to prevent "deep discharging" of the battery.
FEATURES
•Switching Power Supply, no transformer needed.
•Regulated 12VDC Output, capable of delivering 4 Amps.
•Automatic Resetting Overload Protection.
•Three Individually PTC Fused (2.5A) DC Power Outputs.
•Master AC and Battery ON / OFF Power Switch.
•Visual AC and DC LED Power Indicators.
•Built-In Battery Charging Circuit.
•Includes (1) Six foot AC Power Cord and cable clamp.
•Heavy Duty Enclosure.
•Lifetime Limited Warranty, call for details.
•Automatic Low Battery Cutoff Circuit Protects Battery
from Deep Discharge.
SPECIFICATIONS
•DC Output Voltage: 13.8 Volts D.C.
•Current Rating: 4 Amps .
•Auto Resetting "fuseless" circuit breakers (PTC).
•AC Input Voltage Range: 85~264VAC @ 47~63Hz.
•Low Battery Cutoff: ~=10 Volts.
•Ripple & Noise: 100mVp-p.
•Enclosure Dimensions: 12"H x 12"W x 3.25"D.
Features and Specications subject to change without notice.
ELK-P412
6/17
ELK-P412 Installation & Hookup Examples
APPLICATION: AC Power Failure Indicator
This hookup will activate a 12 volt sounder if AC Power
is lost. The ELK-912 relay will be energized while AC
Power is ON. If AC Power is lost then the relay will turn
off closing the COM and N.C. contacts to activate the
sounder. The sounder is powered from the Battery.
APPLICATION: 4 AMP HOOKUP
Parallel any two outputs together for heavy loads up to
4 AMPS continuous. The third output can not be used
in this conguration.
BLOCK DIAGRAM of DC Output Terminals
Each output can provide up to 2.5 Amps each (fused
at 2.5 amps). However, the combined load from all
outputs must not exceed 4 Amps continuously.
2.5 AMP
FUSE (PTC)
(CURRENT DRAW OVER 4 AMPS WILL COME FROM THE BATTERY)
2.5 AMP
FUSE (PTC)
2.5 AMP
FUSE (PTC)
OUTPUT 1
UP TO
2.5 AMPS
OUTPUT 2
UP TO
2.5 AMPS
OUTPUT 3
UP TO
2.5 AMPS
APPLICATION: DUAL 2 AMP HOOKUP
For two separate 2 Amp continuous loads. DO NOT
EXCEED 4 AMPS TOTAL. The third output can not be
used in this conguration.
BLACK RED
12 Volt
Battery
(ELK-1270)
(Purchase Separately)
OUTPUT 3
CAN NOT BE
USED IN THIS
CONFIGURATION
2 AMP LOAD
(Sirens,etc)
2 AMP LOAD
(Cameras, etc)
AC
INPUT
+
POWER
ON
POWER ON LEDS
L N -V +V
DC
OUTPUT
EARTH
GROUND
Power Supply
POWER
OFF
SW1
+
WARNING
SHOCK
HAZARD
GRDNEUTRLLINE
NEG +12V
OUTPUT 3
BATTERY
NEG +12VNEG +12V
OUTPUT 2OUTPUT 1
14.5VDC IN
AC
LED
FACTORY SET
DO NOT ADJUST
Power Distribution Module
120 VAC
Input
BATTERY
BLACK RED
OUTPUT 3
CAN NOT BE
USED IN THIS
CONFIGURATION
4 AMP LOAD
(CONTINUOUS)
12 Volt
Battery
(ELK-1270)
(Purchase Separately)
AC
INPUT
+
POWER
ON
POWER ON LEDS
DC
OUTPUT
EARTH
GROUND
POWER
OFF
SW1
+
WARNING
SHOCK
HAZARD
GRDNEUTRLLINE
NEG +12V
OUTPUT 3
NEG +12VNEG +12V
OUTPUT 2OUTPUT 1
14.5VDC IN
AC
LED
FACTORY SET
DO NOT ADJUST
Power Distribution Module
120 VAC
Input
BLACK RED
12 Volt
Battery
(ELK-1270)
(Purchase Separately)
AC
INPUT
NEG
+
POWER
ON
POWER ON LEDS
L N -V
DC
OUTPUT
EARTH
GROUND
Power Supply
POWER
OFF
SW1
+
+12V
OUTPUT 1
NEG +12V
OUTPUT 2
GRDNEUTRLLINE
WARNING
SHOCK
HAZARD
Voltage is lost here during AC Power
Failure which will cause the relay to
drop out and activate the sounder
12 VOLT
SOUNDER
-
+
+V
AC
LED
FACTORY SET
DO NOT ADJUST
NEG +12V
OUTPUT 3
BATTERY
NO COM NC
14.5VDC IN
ELK-912
RELAY
Power Distribution Module
120 VAC
Input