Elmdene LM-PA-G3 Series User manual

E G LM-PA-G3-X Panic Button uide
Operating Life >1 x 10 operations
8
Specifications
Temperature Range -10°C to+40°C
Contact
Current Rating 1.0A Max
Resistance <300mohms
Power Handling 10VA
Dimension x mms 62 80 x 27
Voltage Rating 30Vdc
X is colour code: ELM-PA-G3-W White, ELM-PA-G3-B Brass, ELM-PA-G3-SS Steel
ELM-PA-G3-BK Black
Elmdene International Ltd PAK Iss 0 Page 1 2019 200464 June 2019 3D
Technical Support Line + 44 (0) 2392 696638
Setting reed - Normally Open (N.O.) or Normally Closed (N.C.)
Default is set to Normally closed. Please skip this section if this is the required setting.
1. Tab
Tab
Follow steps 1&2 in reverse order to re-assemble. Take care not to damage the reed switch.
Wall Mounting
3. Drill holes to required depth and use appropriate wall plugs or fixings (No. 6 / 5mm).
2. Mark positions of holes on the wall.
5. Insert top screw through PCB and plastic and screw into wall. pan head Take care not to snap
the PCB tamper breakout.
6. Use friction adjustment screw to ensure sliding mechanism does not move without being pushed
by buttons or reset key. DO NOT OVERTIGHTEN
7. Angle lid as shown above. Slide upward pushing lid closed. Fasten lid shut with screw.before
1. Press both buttons to move mechanism out of the way and gain access to the bottom fixing hole.
4. Drive bottom screw through base and into wall.countersunk
Use of the PA button
Correct Use of PA Buttons
indicator will be red (latched).
2. To reset insert the key into the slot as shown.
4. Turn the key anticlockwise back to the start and remove it.
5. Indicator will now be yellow (ready).
3. Turn key clockwise as far as it will turn (about 120
degrees) to reset the PA.
1. Push both buttons together to operate. After use
PA buttons should be installed in accordance with any applicable
regulations relating to panic alarms. Potential users should be advised in
the use of the PA.
Page 2
Top mounting
screw hole
Bottom mounting
screw hole
2. 3.
Friction
Adjustment
Screw
Normally Closed
(Factory Default)
Normally
Open
2. Remove the sliding
mechanism (you may need
to loosen the
adjustment screw).
friction
3. Push out magnet from other
side and swap to desired
position.
1. Remove PCB by gently
bending the two tabs back
and pull the board up and
out.
Features include:
• Silent two button operation
S• uitable for use under the ACPO “10 point plan” for false PA reduction
• Integral, selectable resistor values for easy FSL connection to most alarm control
C 17 the rity• ompliant with PD6662: 20 , and requirements of EN 50131-1:2006, Secu
grade 3, Environmental class II.
• Spare terminals for connection of multiple units
panels.
• Key operated mechanical reset
• Cover and removal from wall tamper (normally closed)
Visual indication of ready or latched state•
• Alternative double pole wiring option
• Selectable normally open or normally closed alarm contacts
A range of aesthetically pleasing two button panic alarm (PA) devices available with
white, brass or stainless steel appearance covers. Suitable for commercial and domestic
installation
black,
.
Panic alarm trigger device with two push buttons
Meets the requirements of 17 at Grade 3, Environmental Class II and PD6662: 20 EN
50131-1:2006.
To
Control
Panel 6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
Multiple PA (Parallel Resistor Configuration)
FSL Wiring Two PA (Series Resistor Configuration)
EOL R 
LX 
Shunt R 
EOL R 
Shunt R 
LX 
Single PA (Parallel or Series)
Two PA (Parallel Resistor Configuration)
 = Fit jumper shown
 = Do Not Fit jumper
Follow Instructions
LX = Link near terminal 1
For additional PAs, connect as “Other PAs”
Shunt R 
LX 
EOL R 
Jumper
Settings
PA 1 PA 2
To
Control
Panel
6
5
4
3
2
1
To
Control
Panel
6
5
4
3
2
1
6
5
4
3
2
1
Jumper
Settings
PA 1 PA 2
Jumper
Settings
Shunt R
EOL R
LX



Multiple PA (Series Resistor Configuration)
To
Control
Panel
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
EOL R 
Shunt R 
LX 
Last PA
Shunt R 
LX 
EOL R 
Other PAs
EOL R 
LX 
Shunt R Shunt R 
LX 
EOL R 
Jumper
Settings
First PA Second PA
6
5
4
3
2
1
To
Control
Panel 6
5
4
3
2
1
6
5
4
3
2
1
For additional PAs, connect as “Other PAs”
Shunt R 
LX 
EOL R 
Last PA
EOL R 
LX 
Shunt R 
Last but one PA
EOL R 
LX 
Shunt R Shunt R 
EOL R 
LX 
Jumper
Settings
First PA
LX 
Shunt R 
EOL R 
6
5
4
3
2
1
Two PA
PA 1
Tamper
Circuit
6
5
4
3
2
1
Alarm
Circuit
PA 2
Wiring the PA Button
Connections to the PA button are made via the screw terminals numbered 1 to 6.
Configuration of the resistor values to match the alarm panel is by link jumpers.
See the table below to find the resistor values and series or parallel option
needed.
Shunt and EOL Resistors by Control Panel Manufacturer
Control Panel Shunt EOL Configuration
Resistor Resistor
ADE, Bosch, Castle, Menvier, Pyronix, Scantronic, Texecom 4k7 2k2 Series
Honeywell (Galaxy) 1k0 1k0 Series
Bosch, Europlex 2k2 2k2 Series
GE, Aritech, Pyronix 4k7 4k7 Series
Guardall 8k2 8k2 Parallel
Gardtec 6k8 4k7 Series
DSC 5k6 5k6 Series
FSL Wiring (Shunt and EOL Resistor)
Location of Configuration Parts
1
2
3
4
5
6
Terminal
Connections
(Chosen by link jumper)
EOL Resistor
Shunt Resistor
(Chosen by link jumper)
(See text and diagrams)
Configuration LX
= LX Jumper Fitted
= LX Jumper Not Fitted
Double Pole Wiring - REMOVE ALL JUMPERS
Double - Pole Wiring REMOVE ALL JUMPERS
Single PA
Tamper
Circuit
6
5
4
3
2
1
Alarm
Circuit
6
5
4
3
2
1
Multiple PA
First PA
Tamper
Circuit
6
5
4
3
2
1
Alarm
Circuit
6
5
4
3
2
1
6
5
4
3
2
1
Other PAs Last PA
For additional PAs, connect
as “Other PAs”
Last but one PA
Other PAs
= LX Jumper Not Fitted
= LX Jumper Fitted
Page 4
Page 3

This manual suits for next models

4

Other Elmdene Security System manuals

Elmdene ELM-PA-G3 series User manual

Elmdene

Elmdene ELM-PA-G3 series User manual

Elmdene Quartz-3000-G3 User manual

Elmdene

Elmdene Quartz-3000-G3 User manual

Popular Security System manuals by other brands

Qlightec SPNA manual

Qlightec

Qlightec SPNA manual

Honeywell System 1500e owner's manual

Honeywell

Honeywell System 1500e owner's manual

DesignTech Smart Entry 20083 / 25583 installation manual

DesignTech

DesignTech Smart Entry 20083 / 25583 installation manual

Serene CA-SOS user manual

Serene

Serene CA-SOS user manual

Swann SwannSecure instruction manual

Swann

Swann SwannSecure instruction manual

Swann SW351-WSA operating instructions

Swann

Swann SW351-WSA operating instructions

STI Exit Stopper STI-6400 Series quick start guide

STI

STI Exit Stopper STI-6400 Series quick start guide

Skov DOL 2400 user manual

Skov

Skov DOL 2400 user manual

werma 741 Series Instructions for use

werma

werma 741 Series Instructions for use

COMPRO CO BL 50 AL 230 2F manual

COMPRO

COMPRO CO BL 50 AL 230 2F manual

Doro 450 user guide

Doro

Doro 450 user guide

Datel CAT SHARK user guide

Datel

Datel CAT SHARK user guide

ACTii AC3828 user manual

ACTii

ACTii AC3828 user manual

Interlogix ATS1235 Installation sheet

Interlogix

Interlogix ATS1235 Installation sheet

DSC PG9938 Installation instruction

DSC

DSC PG9938 Installation instruction

eTIGER S4 Cell + Line quick start guide

eTIGER

eTIGER S4 Cell + Line quick start guide

M2M RControl-LA Installation and programming guide

M2M

M2M RControl-LA Installation and programming guide

Smanos W120 quick start guide

Smanos

Smanos W120 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.