manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ELRO
  6. •
  7. Accessories
  8. •
  9. ELRO AG40MA11 User manual

ELRO AG40MA11 User manual

Other ELRO Accessories manuals

ELRO DB200 User manual

ELRO

ELRO DB200 User manual

ELRO DB301 User manual

ELRO

ELRO DB301 User manual

ELRO LP152011 User manual

ELRO

ELRO LP152011 User manual

ELRO DB2000 User manual

ELRO

ELRO DB2000 User manual

ELRO HE821S User manual

ELRO

ELRO HE821S User manual

ELRO AG40PP11 User manual

ELRO

ELRO AG40PP11 User manual

ELRO TWIN LEDSPOT 2 x 10 WATT User manual

ELRO

ELRO TWIN LEDSPOT 2 x 10 WATT User manual

ELRO DVC04C User manual

ELRO

ELRO DVC04C User manual

ELRO DB245 User manual

ELRO

ELRO DB245 User manual

ELRO DB3000 Series User manual

ELRO

ELRO DB3000 Series User manual

ELRO AS90PLE User manual

ELRO

ELRO AS90PLE User manual

ELRO DB260 User manual

ELRO

ELRO DB260 User manual

ELRO DVC040IP User manual

ELRO

ELRO DVC040IP User manual

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Home is not a place, it’s a feeling
AG40MA11
DOOR- / WINDOW SENSOR
MANUAL EN
Symbols:
Recycling and disposal: The WEEE symbol (a) means that this product and baeries must be disposed
separately from other household waste. When it reaches its end of life, take it to a designated waste collecon
point in your area to guarantee a safe disposal or recycling. Protect the environment, human health and natural
resources! Read the manual (b) before use and store it in a safe place for future use and maintenance.
ELRO Europe | www.elro.eu
Postbus 9607 - Box E800
1006 GC Amsterdam - Nederland
ü
GUARANTEE
Visit www.elro.eu (a) (b) V2
MOUNTING
Remove the baery cover (d) and mount it using either adhesive tape or screws, and then aach the sensor (a)
and fix it with the screw at the boom. When using screws, use the baery cover as a mold to mark drilling
holes. Next, fit the magnet (b) to the door (or, in the case of double doors, to the most commonly used door).
Ensure that the parallel gap (g) between the magnet and sensor is less than 10mm and the magnet is aligned
with the sensor by using the lines in the middle of both the sensor and the magnet.
IMPORTANT WARNING:
This package can contain small parts and/or
materials which can be dangerous to small
children! Be aware of this, and keep this away
from small children!
SPECIFICATIONS
Baeries: 1,5V / AAA x 3
Frequenty: 868 MHz
Range: Min.100m in open air
Measurements sensor: 120 x 28 x 20 mm
Measurements magnet: 45 x 9 x 15 mm
For more informaon about the HOME ALARM SYSTEM AG400011 visit www.elro.eu
-3-
(g)
32mm
55mm
(d)
(a)
(b)
INTRODUCTION
The door/window sensor AG40MA11 is designed for use with the Home Alarm System AG400011.
The Magnec sensor consists of two parts; a detector (a) and a magnet (b). Designed to be fied to doors or
windows with the magnet mounted on the moving/opening part, and can then detect when the door or
window is opened.
INSERTING BATTERIES
Unscrew the screw (c) at the boom of the sensor to remove the rear cover (d), and place the 3 included 1.5V
AAA baeries in the baery compartment. Ensure you are not pressing the tamper switch (e) on the boom of
the sensor. Then remove or bring the magnet to the detector, the LED (f) of the detector lights up.
LINKING TO THE HOME ALARM SYSTEM AG400011
Before mounng the sensor, you must first link the sensor to the alarm panel. When adding a sensor to the
alarm system, it can be added under five different security types that differ based on in which mode they can
give an alert and whether or not there is a delay. The types are:
- Security Type “0”: Fully Armed: The sensor will be acvated only when the system is in Full Arm mode. This
sensor will not be acvated in Paral Arm mode. When the sensor is triggered, the alarm will sound
immediately without any preset delay.
- Security Type “1”: Parally Armed and Fully Armed: The sensor will be acvated when the system is either
fully or parally armed. When the sensor is triggered the alarm will sound immediately without any preset
delay.
- Security Type “2”: Fully Armed + Delay: Same as Security Type “0”, except when the sensor is triggered the
alarm will sound aer a preset Entry delay. This is mostly used for the main entrance to prevent any
accidental triggering of the alarm by the user.
- Security Type “3”: Paral Arm and Fully Arm + Delay: Same as Security Type “1” except when the sensor is
triggered the alarm will sound aer a preset Entry delay. This is mostly used for the main entrance to
prevent any accidental triggering of the alarm by the user.
- Security Type “4”: 24Hrs intruder: The sensor will immediately trigger an alarm, regardless whether the
system is (parally) armed or disarmed. This is normally used to protect areas from any unauthorized access,
such as a safe box or an electrical maintenance room, etc.
When you have selected which security type fits best with the sensor you are using, follow these steps to link
the sensor to the alarm system:
1. Ensure you have inserted the baeries so that the sensor is powered on
2. On the alarm panel, enter your PIN + DISARM key to disarm the system.
3. Then enter your PIN + 15 + (Security Type) + PARM to start the binding process.
The DISARM LED will start to blink for 30 seconds with a beep tone.
4. Within 30 seconds, set the sensor to enter binding mode by pressing the tamper key on the back for a few
seconds and releasing.
5. If the sensor has been successfully linked to the alarm panel, the DISARM LED will turn on for 1 second
and you will hear a long beep. A keypad LED will turn on to indicate the zone number that has been assigned
to the sensor (Numbers 1-9 for zones 1-9, 0 for sensor zone 10 or higher). We advise you to note down the
locaon and the zone number.
6. If binding fails, it will meout aer 30 seconds and 3 short beeps will be heard.
7. To exit the binding process, press the DISARM key.
TESTING
Decide which doors/windows are to be protected by fing magnec contact sensors, (usually the front and
back doors). Addional sensors may also be fied where required to other vulnerable doors or windows, (e.g.
garage, pao doors etc.).
Before mounng, it is wise to first test the contact where you want to mount it, to ensure it is within range of
the control panel. To test enable test mode on the alarm panel by entering your PIN + 03 + PARM key.
Next press and release the tamper switch on the back of the sensor when you are holding it near the place
where you want to mount it, you should now hear a chime from the alarmpanel. When you have finished the
test, press the DISARM key to exit test mode.
-1- -2-
1 2
ON
AAA - 1,5V
AAA - 1,5V
Tamper
switch
55mm
32mm
(a)
(b)
(c)
(f)
(d)
(e) (e)
Alternave
mounng