Emerson RTM-ATCA-F125 Quick start guide

Embedded Computing for
Business-Critical ContinuityTM
RTM-ATCA-F125
Installation and Use
P/N: 6806800K30C
December 2012

© 2011-2012 Emerson
All rights reserved.
Trademarks
Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service
marks of Emerson Electric Co. © 2011 Emerson Electric Co. All other product or service names are the property of their respective
owners.
Intel®is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries.
Java™and all other Java-based marks are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and other
countries.
Microsoft®, Windows®and Windows Me®are registered trademarks of Microsoft Corporation; and Windows XP™is a trademark of
Microsoft Corporation.
PICMG®, CompactPCI®, AdvancedTCA™and the PICMG, CompactPCI and AdvancedTCA logos are registered trademarks of the PCI
Industrial Computer Manufacturers Group.
UNIX®is a registered trademark of The Open Group in the United States and other countries.
Notice
While reasonable efforts have been made to assure the accuracy of this document, Emerson assumes no liability resulting from any
omissions in this document, or from the use of the information obtained therein. Emerson reserves the right to revise this document
and to make changes from time to time in the content hereof without obligation of Emerson to notify any person of such revision or
changes.
Electronic versions of this material may be read online, downloaded for personal use, or referenced in another document as a URL to
a Emerson website. The text itself may not be published commercially in print or electronic form, edited, translated, or otherwise
altered without the permission of Emerson,
It is possible that this publication may contain reference to or information about Emerson products (machines and programs),
programming, or services that are not available in your country. Such references or information must not be construed to mean that
Emerson intends to announce such Emerson products, programming, or services in your country.
Limited and Restricted Rights Legend
If the documentation contained herein is supplied, directly or indirectly, to the U.S. Government, the following notice shall apply
unless otherwise agreed to in writing by Emerson.
Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (b)(3) of the Rights in
Technical Data clause at DFARS 252.227-7013 (Nov. 1995) and of the Rights in Noncommercial Computer Software and
Documentation clause at DFARS 252.227-7014 (Jun. 1995).
Contact Address
Emerson Network Power - Embedded Computing
2900 South Diablo Way, Suite 190
Tempe, AZ 85282
USA

Contents
RTM-ATCA-F125 Installation and Use (6806800K30C) 3
About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.2 Standard Compliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.3 Mechanical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
1.4 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
2 Hardware Preparation and Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
2.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
2.2 Unpacking and Inspecting the RTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
2.3 Environmental and Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
2.3.1 Environmental Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
2.4 RTM Installation and Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.4.1 Installing the RTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.4.2 Removing the RTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
3 Controls, LEDs, and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3.2 Face Plate Connectors and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3.2.1 LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
4 Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
4.1 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
4.2 Management Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
4.2.1 FRU Serial EEPROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
4.2.2 Temperature Sensors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
4.2.3 LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
4.2.4 I2C Address Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
4.3 1 Gbps SFP Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
4.3.1 Connectivity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
4.3.2 Front-Blade Port Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
4.3.3 SFP Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Contents

RTM-ATCA-F125 Installation and Use (6806800K30C)
Contents
4
Contents
Contents
4.3.3.1 I2C Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
4.3.3.2 SFP Status Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
4.3.3.3 SFP Control Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
4.4 10 Gbps SFP+ Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
4.4.1 Connectivity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
4.4.2 Front-Blade Port Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
4.4.3 BCM8747 Configuration Flash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
4.4.4 Transmitter Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
4.4.5 BCM8747 Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
4.4.6 SFP+ Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
4.4.6.1 I2C Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
4.4.6.2 SFP+ Status Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
4.4.6.3 SFP Control Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
4.5 GPS Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
4.6 FPGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
4.6.1 Front-blade Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4.6.2 SFP/SFP+ Control and Status. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4.6.3 BCM8747 Control and Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4.6.4 SFP I2C Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
4.6.5 Reset Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
4.6.6 BCM8747 SPI Flash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
4.6.7 FPGA Register Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
4.6.8 FPGA Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
4.7 Reset Scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
4.8 Power Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
4.8.1 Power-good Indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
4.8.2 Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
A Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
A.1 Emerson Network Power - Embedded Computing Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

Contents
RTM-ATCA-F125 Installation and Use (6806800K30C) 5
Safety Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Sicherheitshinweise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

RTM-ATCA-F125 Installation and Use (6806800K30C)
Contents
6
Contents
Contents

List of Tables
RTM-ATCA-F125 Installation and Use (6806800K30C) 7
Table 1-1 Standard Compliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table 1-2 RTM-ATCA-F125 Mechanical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Table 1-3 Blade Variants - Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Table 2-1 Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Table 4-1 Temperature Sensor Thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 4-2 PCF 8574 Port Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Table 4-3 I2C Bus Address Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Table 4-4 Front-Blade Port Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Table 4-5 SFP Connector Pin Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Table 4-6 10 Gbps SFP+ Front-Board Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Table 4-7 SFP+ Connector Pin Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Table 4-8 FPGA Configuration Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Table 4-9 Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Table A-1 Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

RTM-ATCA-F125 Installation and Use (6806800K30C)
8
List of Tables

List of Figures
RTM-ATCA-F125 Installation and Use (6806800K30C) 9
Figure 1-1 Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Figure 3-1 Face Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 4-1 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 4-2 1GB Base Channel Interconnect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Figure 4-3 Fabric 10 GB Interconnect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

RTM-ATCA-F125 Installation and Use (6806800K30C)
10
List of Figures

RTM-ATCA-F125 Installation and Use (6806800K30C) 11
About this Manual
Overview of Contents
This manual is divided into the following chapters and appendices.
zIntroduction describes the main features of the RTM.
zHardware Preparation and Installation installation prerequisites and the installation itself.
zControls, LEDs, and Connectors describes external interfaces such as connectors and LEDs.
zFunctional Description contains a block diagram ofthe RTM and provides some information
on the IPMI functionality of the RTM.
zRelated Documentation lists further Emerson user manuals that are related to the RTM and
the ATCA-F125.
Abbreviations
This document uses the following abbreviations:
Abbreviation Definition
AMC Alarm Management Controller
ARP Address Resolution Protocol
ATCA Advanced Telecom Computing Architecture
BIX Base Interface Switch
CP-TA Communications Platforms Trade Association
FIX Fabric Interface Switch
IO Input/Output
PICMG PCI Industrial Computer Manufacturers Group
PCI Peripheral Component Interconnect
RTM Rear Transition Module
SPI Serial Peripheral Interface

RTM-ATCA-F125 Installation and Use (6806800K30C)
About this Manual
12
About this Manual
Conventions
The following table describes the conventions used throughout this manual.
Notation Description
0x00000000 Typical notation for hexadecimal numbers (digits are
0 through F), for example used for addresses and
offsets
0b0000 Same for binary numbers (digits are 0 and 1)
bold Used to emphasize a word
Screen Usedforon-screenoutput and coderelatedelements
or commands in body text
Courier + Bold Used to characterize user input and to separate it
from system output
Reference Used for references and for table and figure
descriptions
File > Exit Notation for selecting a submenu
<text> Notation for variables and keys
[text] Notation for software buttons to click on the screen
and parameter description
... Repeated item for example node 1, node 2, ..., node
12
.
.
.
Omission of information from example/command
that is not necessary at the time being
.. Ranges, for example: 0..4 means one of the integers
0,1,2,3, and 4 (used in registers)
|LogicalOR

About this Manual
RTM-ATCA-F125 Installation and Use (6806800K30C) 13
Summary of Changes
This manual has been revised and replaces all prior editions.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury
Indicates a hazardous situation which, if not avoided,
may result in minor or moderate injury
Indicates a property damage message
No danger encountered. Pay attention to important
information
Notation Description
Part Number Publication Date Description
6806800K30A June, 2011 GA Version
Updated Figure "Declaration of Conformity" on
page 18.
6806800K30B March, 2012 updatedChapter 1, Features, Chapter3, Overview,
Chapter 4, Functional Description, Safety Notes,
and Sicherheitshinweise
6806800K30C December 2012 Updated Chapter 1, Standard Compliances, on
page 15.

RTM-ATCA-F125 Installation and Use (6806800K30C)
About this Manual
14
About this Manual

Chapter 1
RTM-ATCA-F125 Installation and Use (6806800K30C) 15
Introduction
1.1 Features
The RTM-ATCA-F125 provides the I/O connection for the ATCA-F125 switch blade towards the
back of the system. RTM-ATCA-F125 is directly connected to and powered by the front board.
The RTM-ATCA-F125 is a rear transition module (RTM) as defined in PICMG 3.0 Revision 3.0
Advanced TCA Base Specification and PICMG 3.1 Revision 1.0 Specification Ethernet/Fiber
Channel for AdvancedTCA Systems. It provides several Base and Fabric Channel Ethernet
interfaces connected to the front board through the Zone 3 connector.
The main features of the RTM-ATCA-F125 are:
zSingle slot RTM form factor (70mm x 322mm)
z6x 10 Gbit Ethernet uplinks (FIX) according to IEEE 802.3ak with 6 SFP+ type connectors
z2x 10 Gbit Ethernet uplinks (BIX) according to IEEE 802.3ak with 2 SFP+ type connectors
z4x 1 Gbit Ethernet interfaces (BIX) with 4 SFP type connectors
zSerial EEPROM accessible by front-blade IPMC
zFour status LEDs and ejector handle switch accessible by front-blade IPMC
1.2 Standard Compliances
The product is designed to meet the following standards.
Table 1-1 Standard Compliances
Standard Description
ANSI Fire Spread Criteria The product is designed to pass the ANSI T1.319-2002 fire
spread test method as well as the NEBS GR-63-CORE fire spread
test method.
AS/NZS CISPR 22 Class A
(Australia/New Zealand)
The product complies with AS/NZS CISPR 22 Class A
(Australia/New Zealand), Limits and Methods of Measurement
of Radio Disturbance Characteristics of Information Technology
Equipment.
AT&T Document ATT-TP-76200 The product is designed to comply with the latest version of the
AT&T Document ATT-TP-76200: Network Equipment Power,
Grounding, Environmental, And Physical Design Requirements.

Introduction
RTM-ATCA-F125 Installation and Use (6806800K30C)
16
EN 55024 (EU) The product complies with EN55024 (EU) Information
Technology Equipment - Immunity Characteristics - Limits and
Methods of Measurements.
EN 60950-1 This product complies with EN 60950-1 Safety of Information
Technology Equipment.
EN55022 Class A (EU) The product complies with EN55022 Class A (EU), Information
Technology Equipment - Radio Disturbance Characteristics -
Limits and Methods of Measurements.
ETSI Acoustic Noise ETS 300 753
Class 3.1 The product will not prevent the system from complying
with the ETSI acoustic noise requirements per Class 3.1 of ETSI
ETS 300 753, Equipment Engineering (EE); Acoustic noise
emitted by telecommunications equipment.
ETSI Stationary Use: EN 300 019-
2-3 Class 3.1
The product is designed to comply with ETSI Stationary Use: EN
300 019-2-3, Class 3.1 equipment (temperature controlled
locations).
ETSI Storage EN 300 019-2-1
Class 1.2
The product is designed to comply with ETSI Storage: EN 300
019-2-1, Class 1.2 equipment (not temperature controlled
storage locations).
ETSI Transportation: EN 300 019-
2-2 Class 2.3
The product is designed to comply with ETSI Transportation: EN
300 019-2-2, Class 2.3 equipment (public transportation).
FCC 47 CFR Part 15 Subpart B
(US), Class A
The product complies with FCC 47 CFR Part 15 Subpart B (US),
Class A.
GR-1089 - Ports and Intra-
building Lightning
All externally accessible ports shall be designed to comply with
the applicable GR-1089 requirements for Telecommunication
Ports.
GR-1089-CORE Products are designed to comply with all applicable
requirements for Type 2 Equipment referenced in Telcordia
Document GR-1089-CORE.
GR63-CORE The product is designed to comply with all applicable
requirements of Telcordia GR-63-CORE, NEBS Requirements:
Physical Protection.
IEC 60950-1 CB Scheme The product complies with IEC 60950-1 CB Scheme including all
National Deviations Safety of Information Technology
Equipment. Testing shall be by an accredited lab.
Table 1-1 Standard Compliances (continued)
Standard Description

Introduction
RTM-ATCA-F125 Installation and Use (6806800K30C) 17
For Declaration of Conformity, refer RTM-ATCA-F125 Declaration of Conformity..
1.3 Mechanical Data
NEBS Level 3 Module is designed to pass all testing to Criteria Level 3 per
Telcordia SR-3580.
Safety Mark for U.S. and Canada The product is designed to certify to UL/CSA No. 60950-1 with
no deviations and shall bear the Recognition Mark of an NRTL for
US and Canada.
UL/CSA No. 60950-1 The product complies with UL/CSA 60950-1Safety of
Information Technology Equipment.
VCCI Class A (Japan) The product complies with VCCI Class A (Japan), Voluntary
Control Council for Interference by Information Technology
Equipment.
Verizon CHECKLIST The product is designed to comply with the latest version of the
Verizon Document VZ.NEBS.TE.NPI.2004.015: NEBS Checklist.
Table 1-1 Standard Compliances (continued)
Standard Description
To fulfill the requirements of Telcordia GR-1089,R4-14, use Shielded Twisted Pair (STP) cables
grounded at both ends to connect to the Ethernet ports.
Table 1-2 RTM-ATCA-F125 Mechanical Data
Data Value
Dimensions 8U x 6 HP form factor - 30mm x 351 mm x143 mm (including face plate
handles and alignment posts)
Weight 0.635 Kg

Introduction
RTM-ATCA-F125 Installation and Use (6806800K30C)
18
1.4 Ordering Information
The following table lists the blade variants that were available as of the time of writing this
manual. Consult your local Emerson sales representative for the availability of further variants.
Table 1-3 Blade Variants - Ordering Information
Part Number Description
RTM-ATCA-F125 RTM for the ATCA-F125 with SFP and SFP+ sockets.

Chapter 2
RTM-ATCA-F125 Installation and Use (6806800K30C) 21
Hardware Preparation and Installation
2.1 Overview
zInspect the shipment and unpack the RTM.
zMake sure environmental and power requirements are met.
zInstall the RTM.
2.2 Unpacking and Inspecting the RTM
The shelf should provide minimum airflow to the RTM slot according to the class B.3
requirements of the CP-TA Inter-operability document AdvancedTCA Book 1.1. This includes
the following:
z2.0 cfm at 25 °C ambient temperature
z2.8 cfm at 40 °C ambient temperature
z4.4 cfm at 55 °C ambient temperature
Shipment Inspection
To inspect the shipment, perform the following steps:
1. Verify that you have received all items of your shipment:
zPrinted Quick Start Guide and Safety Notes Summary
zRTM-ATCA-F125
Damage of Circuits
zElectrostatic discharge and incorrect installation and removal of the blade can damage
circuits or shorten its life.
zBefore touching the blade or electronic components, make sure that you are working in
an ESD-safe environment.

Hardware Preparation and Installation
RTM-ATCA-F125 Installation and Use (6806800K30C)
22
2. Check for damage and report any damage or differences to the customer service.
3. Remove the desiccant bag shipped together with the blade and dispose of it according to
your country’s legislation.
2.3 Environmental and Power Requirements
In order to meet the environmental requirements, the blade has to be tested in the system in
which it is to be installed.
Before you power up the blade, calculate the power needed according to your combination of
blade upgrades and accessories.
2.3.1 Environmental Requirements
The environmental conditions must be tested and proven in the shelf configuration used. The
conditions refer to the surrounding of the blade within the user environment.
zThe RTM is thoroughly inspected before shipment. If damage has occurred or items
missing during transportation, contact our customer's service immediately.
zRemove the desiccant bag shipped together with the blade and dispose of it according to
your country’s legislation.
zThe environmental requirements of the blade may be further limited down due to
installed accessories, such as hard disks or PMC modules, with more restrictive
environmental requirements.
zOperating temperatures refer to the temperature of the air circulating around the blade
and not to the actual component temperature.
Table of contents
Other Emerson Adapter manuals

Emerson
Emerson Rosemount 775THUM User manual

Emerson
Emerson Smart Wireless THUM Adapter User manual

Emerson
Emerson CFDC Series User manual

Emerson
Emerson LIEBERT MULTILINK IRACKMLADPT User manual

Emerson
Emerson Smart Wireless THUM Adapter User manual

Emerson
Emerson THUM User manual

Emerson
Emerson Rosemount 326 User manual

Emerson
Emerson Smart Wireless THUM Adapter User manual

Emerson
Emerson Smart Wireless THUM Adapter User manual

Emerson
Emerson Smart Wireless THUM Adapter User manual