User manual body 600 med/600 Version 5.0
Page 16 of 20
Distance / Distance training
The distance training works in a rpm-dependent mode, which means that the intensity adjusts when the rpm changes. For this
program, the parameters distance and intensity level/gear (1-21) must be pre-selected. At any time during the workout, the level
can be adjusted with +/-. The chosen distance will countdown and the intensity is determined from among the 21 intensity
levels. The workload is shown in km/h in the display. The time that is needed to complete the distance can be used as an
indicator of performance.
After completing the program, a display of the results is initiated.
Isokinetic / Power training
The isokinetic program is a variation in the area of ergometer training. A target rpm has to be set at the beginning of the
workout. The user can select from the entire range of wattage. The user defines the resistance himself by aiming to achieve a
higher rpm. At a low target rpm, the program can be used as strength training. The user always determines the intensity. This can
be very effective when used by persons with limited physical capabilities due to joint injuries.
The biofeedback function gives a visual feedback when the target rpm is achieved or exceeded.
Watt sensitive (not available for fitness units)
Watt constant training programs are likely to be used in the field of training control and therapy, because the intensity control
can be very accurate. As long as there are no orthopaedic reasons for therapy, the rpm-independent power control of
ergometers has a lot of advantages.
However, if problems in the extremities used exist, the rpm-independent power control can lead to overstress. A reduction of
the rpm increases the pedal impact a lot and can lead to overstress or program abort.
To eliminate these negative aspects, excessive torsion can be avoided in the watt sensitive program by an intelligent program
control. During the program setting, a rpm limit gets selected. When the limit gets undercut the pedal resistance gets redeemed
immediately.
Also the overshoot of the limited heart rate gets controlled. When it gets overshot for a longer time, a watt reduction of 10%
every 30 seconds is the result (see motion pulse manager brochure).
The target resistance will be reached via a ramp during the first 2 minutes. That way the trainee gets used to the power and an
adequate warm-up is assured.
The biofeedback function is in this program active and gives feedback according to the target rpm.
Therapy (not available for fitness units)
Also in rehabilitation the total intensity of the training gets controlled with the intensity steering factors workout time as well as
intensity, alongside the recovery progress. As a general rule intensity changes occur by increasing the workload (e.g. increasing of
the wattage). At the therapy training the intensity gets varied several times within the program. After a two minute warm-up in
ramp shape, 6 intervals of one minute each, with one minute active rest (50% of the impact intensity) per interval follow.
The maximum interval impact in watt gets limited as well as the rpm limit below which the pedal power gets clearly decreased.
Also the overshooting of the pre-entered heart rate gets controlled. When overshooting for a longer time a reduction of the
wattage of 10% every 30 seconds follows (see motion pulse manager brochure).
A Cool Down function over 3 minutes rounds up the training. Overall the program lasts 17 minutes.
The biofeedback function is also active in this program and gives feedback according to the target rpm.
4.13 Pulse controlled programs
Concerning the working of pulse controlled programs such as pulse program, Kcal training, Watt sensitive and Therapy, please
refer to the brochure “motion pulse manager”.
4.14 PC-Interface
All ergometers are equipped standardly with an RS232 interface. This interface is not equipped with a galvanic isolation or
external power supply. By this the ergometer can be controlled via a PC, an ECG, spiroergometry device, aso, if both devices are
using the same interface protocol. Please note, that with medical use, the rules for electric safety must be obeyed. Optionally, a
RS232 interface with galvanic isolation can be ordered (when the machine is being build), in order to limit the risk resulting from
any malfunction of the connected device. Please contact your dealer, when you have more questions about this issue.
If the monitor shall be active for a longer period –especially prior to the start of a training/test –a stabilized, medically
approved, 9 Volt power supply unit has to be connected. This is not included in the standard Rs232 setting.
After connecting the power supply, the display is being activated for 3 Minutes and then goes into standby. With the next push
of a button, it is ready instantly.