Instruction manual Pedal ergometer 900 / 900 med Version 1.3 25.01.2023
Page 6 from 17
Place the unit on a firm, horizontal, level and non-slip surface and level the unit with the
adjusting screws so that it does not wobble.
The clearance area around the unit must be at least 1 m larger than the movement
range of the unit to ensure safe access and egress from the unit even in emergencies.
However, the safety clearances may overlap (see picture).
Only place the appliance in dry rooms at , .
Make sure that there is no electromagnetic radiation, e.g. from radio antennas, radiating
fluorescent tubes, etc., as these can affect the pulse measurement.
The underside of the frame must always be free for sufficient ventilation.
All the pedal ergometers mentioned here are mains-independent. They generate the power themselves during
operation or are supplied with power during programming by the standard built-in capacitor. The capacitor is charged
by the training and has a service life of > 20000 cycles.
Attention: Please always follow the instructions for care, maintenance and servicing in chapter 5 of this manual.
Safe training
Before starting training, the fitness for training should be checked by an authorised person, e.g. a doctor. Please
note the point "Indications and contraindications".
Note that excessive exercise can be harmful.
If nausea or dizziness occurs, stop training immediately and consult a doctor.
Training on the equipment is only permitted with intact skin.
When training, tight-fitting, lightweight sports clothing is preferable so that it cannot get caught in parts of the device
during training. Always wear suitable sports shoes for a secure footing on the pedals.
Before starting the training, check the unit for safe standing, defective parts or possible manipulations. If you find
any defects or are not sure, ask the supervisor before starting the training.
Before starting training, make sure that nobody is near the moving parts in order to avoid endangering third parties.
In particular, unsupervised children must be kept away from the equipment.
cycle/relax: For biomechanically correct training, the knee should never be fully extended; adjust the seat of the
device accordingly.With the cycle 900 / 900 med, both the horizontal and the vertical sitting position can be changed.
For the vertical seat position, pull the locking bolt on the front of the seat post and adjust the height manually. For
an easier increase of the seat position, the seat post can be pulled upwards without unlocking the locking bolt. The
locking bolt automatically engages in the nearest lower hole. By pulling the locking bolt, the seat post can be adjusted
further down. Safety: Make sure that the locking bolt engages firmly and audibly before putting any load on the
saddle. The saddle position is indicated by a scale on the side of the seat post so that the personal saddle height
can be found more easily during repeated training. The saddle height should be chosen in such a way that there is
still a knee flexion of about 10° in the lowest pedal position.
Fig.5: Horizontal and vertical adjustment of the seat position on the cycle 900 & cycle 900 med
For horizontal positioning on the cycle, the yellow rubberised clamping handle behind the saddle must be loosened.
The saddle can then be moved forwards or backwards. The horizontal position of the saddle affects the inclination
of the upper body and the load that rests on the arms during the workout.