emporium NEERA WBECEM003 User manual


2
Thank you for choosing the Emporium Neera Ultrasonic Diffuser 300mL. To ensure proper operation
and to maintain the lifespan of your appliance, please read these instructions carefully before use.
1. Mist outlet
2. Outer cover
3. Inner cover
4. Base
5. Light button
6. On/Off button
7. Timer button
8. DC jack
9. Connector
10. AC/DC Adaptor
11. Max water level line
12. Ceramic disc
(ultrasonic mist
plate)
13. Direction to empty
water tank
14. Air outlet
15. Water spout
Safety First
The safety precautions listed below are
intended to prevent you and others from
potential injury and to prevent damage to
the product.
The manufacturer is not responsible for
any damage caused by incorrect use of
the product.
• This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities,
or lack of experience and knowledge,
unless they have been given supervision or
instruction concerning use of the appliance
by a person responsible for their safety.
Children being supervised not to play with
the appliance
• The appliance must only be supplied at
SELV and must be used with the adaptor
power supply provided.
• Do not dismantle or modify the diffuser.
• Do not cut, damage, modify the power cord
or put weight on the power cord.
- This may cause an electric shock or fire.
• This diffuser is solely for ambient diffusion
with essential oils or suitable water soluble
home fragrances. Do not inhale mist.
• Do not use pure essential oils or water
soluble home fragrances without water.
• Only use clean, cool, still tap or bottled
water. Be sure not to exceed the maximum
water level (300 mL). Always pour water into
tank before adding essential oils or water
soluble home fragrance products (10 to 20
drops).
- Use a small jug or other pouring vessel
when adding water to tank. Don’t fill tank
from tap directly.
• Only put water and essential oils or water
soluble home fragrances in tank. Other
liquids may cause irreparable damage to
the unit.
• If diffuser smokes, has a strange smell, or
suggests any abnormal operation, stop
using it immediately.

3
• Do not touch any part of unit with wet
hands.
• Do not let mist spray onto furniture, clothes
or walls directly.
• Spilt essential oils may stain surfaces. Wipe
up any spills immediately.
• Unplug diffuser when not in use.
• Do not cover diffuser with cloth or any other
item during operation.
• Do not allow metal objects or sharp items
(like pins or keys) to come into contact with
ceramic mist plate.
• Do not submerge the diffuser in water.
• Unplug the appliance during filling.
Packaging and Recycling
The materials used for this product’s
packaging can be reused, recycled and
disposed of through specific waste streams.
• REUSE: Keep packaging to safely store
or transport your appliance, preventing
damage.
• RECYCLE: Look for recycling symbols
on packaging components to identify if
they are recyclable. Check with your local
authority to find out what materials are
accepted for recycling in your area.
• DISPOSE: Look for symbols on packaging
and dispose of materials accordingly.
Operating Your Ultrasonic Diffuser
Getting Started
Your diuser uses ultrasonic vibrations to
produce its cool, delicate mist. The ceramic
disk in the base of the diuser’s tank creates
rapid ripples in the liquid above, emitting tiny
particles of water. These droplets then get
dispersed through the mist outlet, carrying
your chosen aromatic essential oil or water
soluble room fragrance.
1. Use in an indoor environment that is
between 10°C and 30°C. Avoid placing
diuser in direct sunlight, on wet surfaces
or in dusty areas.
2. Place diuser on a flat, stable surface, away
from edges of tables or other furniture.
3. Remove outer and inner covers.
4. Fill tank with water. Do not exceed the
maximum water level line (300 mL).
5. Add a few drops of essential oil or water
soluble home fragrance (10-20 drops) to
water tank.
6. Replace inner and outer covers.
7. Plug the connecting cable into DC jack
located on rear of the diuser. Attach
adaptor plug and plug into socket.
Functions
On/O Button:
• First press: Diuser enters continuous mist
mode.
• Press On/O button once and long press
On/O to turn o the light of the control
panel.
• Long press On/O button again to restore
the light of the control panel.
• Second press: Diuser enters intermittent
mist mode (30 seconds on, 30 seconds o
intermittently until tank is empty or diuser
is turned o).
• Third press: Turns o diuser.
Light Button:
• First press: Light illuminates and will
automatically cycle through seven colours.
• Second press: Halts light colour cycle on
your chosen colour.
• Third press: Keeps warm white light.
• Fourth press: Turns o light
When water level in tank is insucient or
empty, diuser will stop automatically.
When this happens, fill tank with water and
oil/fragrance following above instructions.
Diuser can then continue to be used.
Diuser can also be used as an ambient
light without diusion. When diuser is o,
press light button to activate only the light
function.
Timer Button:
• First press: Will set the diuser to run for 1
hour and then turn o automatically after
that time.

4
• Second press: turns 1 hour timer o so the
diuser run consistently until water runs out
or turned o manually by the on/.o button.
Care
• Ensure unit is turned off after use.
• Disconnect connecting cable and remove
adaptor plug from socket.
• Pour out any leftover liquid from tank using
the water spout. Gently dry unit with a soft
cloth. Avoid touching the ceramic disk. It is
particularly important to ensure water has
been removed when the unit is not going to
be used again shortly.
• After every 5-6 uses, clean tank by dipping a
soft cloth in a very diluted, mild dishwashing
liquid and water solution. Gently wipe inside
of tank. Wipe dry with a clean cloth and
cotton bud.
• Never use medical diluents or alcohol to
clean diffuser. These may damage the
product and ceramic disk. Only use water
and a neutral detergent.
Storage
Ensure all parts of diffuser are completely dry
before storing. Store unplugged and in a
dry place.
Size 13.7x18.2cm
Power input /
output
AC-100-240V 50/60 HZ
DC24V0.5A
Cable length
adaptor
150cm
Electric
consumption
12W
Mist Mode continuous / Intermittent 30
sec on/ 30 sec off
Mist Output 30 ml/h +/-5 ml/h
Water capacity 300 mL
Misting time Approx. 9-10 hours in
continuous or 18-20 hours in
intermittent mode
Ultrasonic
Vibration
1.7 MHz
Diffuser does
not turn on
• Check there is water in tank.
• Ensure water level does not
exceed max water level line.
• Diffuser may be too
cold. Wait until ambient
temperature of room
increases.
Diffuser stops
working
suddenly
• Ensure water level does not
exceed max water level line.
• Check DC and adaptor plug
are all connected properly.
Turn off and on.
There is no mist,
or mist looks
abnormal
• Check that water level is
correct.
• Check no dirt or grime is
covering the ceramic disk.
• Use a brush to remove any
dirt/obstructions from the
air inlet or mist outlet.
• Move diffuser to another
room or try again later.
Different ambient humidity
levels and temperatures will
affect mist density.
Water leakage
from diffuser
• Low temperatures or high
humidity may cause mist to
condense quickly into water
droplets.
Product Specifications
Trouble Shooting
This manual suits for next models
1
Popular Accessories manuals by other brands

Waterpik
Waterpik Express user manual

SMC Networks
SMC Networks PSE530 Series Installation & maintenance manual

TREND
TREND LLO installation instructions

Hive
Hive Window or Door Sensor user guide

Lithonia Lighting
Lithonia Lighting OFLR 9LN 120 MO BZ M2 operating instructions

netvox
netvox R718UBB Series user manual