Enerdrive DOMETIC EN-LBC1224-40-G2 User manual

Low Battery Cut-Out User Guide
EN-LBC1224-40-G2 / EN-LBC1224-60-G2
1. Description
The Low Battery Cut-out; EN-LBC1224-40-G2 & EN-LBC1224-60-G2 (hereafter
referred to as the LBC) is an intelligent, user-programmable, fully waterproof
unit.The LBC has expansion options for an o-switch and an alarm output to
which a buzzer, LED strip or relay can be connected. To minimise losses, the LBC
is equipped with 2 bolt-on connections: input+ and output+.The remaining
connections (neg, remote input, programmable input and alarm output) are
connected via separate 6.3mm faston connectors.The LBC is equipped with a
bright status LED which displays how it is functioning.The LBC also features an
“automatic board system detection”, which enables it to automatically detect
whether it is connected to a 12V or a 24V system.
2. Installation
Install the LBC in a cool space to allow for maximum heat dissipation. Use a
power supply cable of up to 50cm for the LBC.This is the only way to accurately
monitor the system’s battery voltage.
PLEASE NOTE
• The product may only be installed by someone who is qualied and fully
aware of the requirements for working with batteries.
• The use of faulty connection material and/or excessively high gauge wiring
may damage the LBC.
• A short circuit between the battery’s positive and negative terminals can
cause serious damage to the system.
• Always use the correct fuses.
• Use at least 1.5mm²cable directly from the battery to the LBC for the
negative (-) connection. Do not use this connection for anything else.
3. Operation
Input Voltage Operation
The input voltage protection values (undervoltage threshold, undervoltage
reset, overvoltage threshold and overvoltage reset) can be set by the user.
See “Programming” for an explanation of how to set these values.
Temperature Protection
The LBC will shut down immediately if its temperature exceeds 85°C.The LED
will indicate a fault.The LBC will turn on again after 1 minute if the
temperature has dropped below 75°C.
Ground Loss Protection
The LBC will shut down if it detects that the negative (-) is disconnected on the
power supply side.The LED will indicate a fault.The LBC will turn on again
after 1 minute.
Remote
A switch can be installed between the remote input and the negative (-) to
manually disable the LBC output.The LBC will shut down immediately when
the connection is made.The LBC will turn on again when the connection is
broken.
2 short blinks (± 0.15 sec) then off for a
long time (± 3.5 sec).
1 blink (± 0.5 sec), then off (± 1.5 sec).
1 blink (±1.0 sec), then off (± 1.0 sec).
3 short blinks (±0.25 sec), then off for a
long time (± 2.5 sec).
LED is off.
LBC is enabled.
LBC is disabled because the remote has
been activated.
Undervoltage or overvoltage detected.
LBC has been shut down for 1 minute due
to one of the following causes: Ground
loss, temperature protection, current
protection, low output voltage.
LBC has been shut down due to
undervoltage.
LED
The LED has 2 functions.The rst is to indicate the LBC’s status. The dierent
options are outlined below.The second is to program the LBC.This operation is
described in the section “Programming”.
IN+
1 2 3 4 LED
ALARM
OUT+
LOAD+
FUSE
REMOTE
PROGRAM
FUSE: 1A
Undervoltage
When the LBC’s input voltage drops below the average threshold for 15
seconds, the alarm output will turn on.The LED will also indicate
undervoltage. The LBC will shut down one minute later and the alarm output
and LED will turn o.When the LBC’s input voltage exceeds the reset threshold
for 5 seconds, the LBC will turn back on, and the LED will indicate that the LBC
is active again.
Overvoltage
The LBC will shut down if the input voltage exceeds the overvoltage threshold
for 0.5 seconds. The alarm output will indicate (at a frequency of 1 Hz) that
overvoltage has been detected.The LED will also display this information.
Overcurrent Protection
The current through the LBC is measured constantly. If an excessive current
ows through the LBC for too long, the LBC will shut down to prevent damage
to both the LBC and the connected equipment.The LBC will turn on again after
1 minute.
LED Code
Fault Description
4. Programming
To enter programming mode, a connection must be made
between the program input and the negative (-).The LED will
blink once if the connection has been maintained for ± 2
seconds. Once this is done, the connection must be broken.
The same connection must be made briey again to set the
correct position number - the LED will light up as feedback.
At that point, program position #1 is selected.The user can
briey make the connection again to select program position #2,
etc.
If no connection is made for ±4 seconds, the LED will display the
set state again. (Eg. program position #4 is set by a user, the LED
will blink 4 times).
2 types of settings are available. Positions 1 through 10 set the
undervoltage threshold and reset values. Positions 11 & 12 set
the overvoltage threshold and reset values.These settings must
be selected individually.
The programmed positions are retained when the battery
voltage is disconnected.
EN-LBC1224-40-G2 / EN-LBC1224-60-G2
Low Battery Cut-Out User Guide
5. Technical Data
Input Voltage Range
40A
6 - 35VDC
300A (± 0.7 sec)
40 mV @ 40A
3.2 mA
3.2 mA
2%
10%
100 mA
10 mm² 16 mm²
1.5 mm²
6.3 mm
M6
Cable Lugs must match the cable diameter used
60 mV @ 60A
60AMaximum continuous output current (@25°C)
Peak Current (@25°C)
Voltage Drop
Current Consumption - Output Active
Current Consumption - Output Inactive
Voltage Accuracy
Current Accuracy
Maximum Alarm Output Load
Minimum Conductor Guage
Bolt Size
Cable Lugs
Minimum Conductor Guage
Faston Plug
FASTON CONNECTIONS
EN-LBC1224-40-G2ELECTRICAL EN-LBC1224-60-G2
EN-LBC1224-40-G2INPUT & OUTPUT CONNECTION EN-LBC1224-60-G2
EN-LBC1224-40-G2 EN-LBC1224-60-G2
Mounting Hole (Ø)
50.5mm
155.4g
4.2mm
72 x 32 x 62.2mm
IP66
PU552
Black
Convection and Conduction
-10°C ~ +40°C
-25°C ~ +85°C
Up to 95%, non-condensing
No
Yes
Yes (after 1 minute restart)
Above 85°C (after 1 minute restart)
Yes, with fuse in the negative (-) line
Distance Between Mounting Holes (centre to centre)
Weight
Dimensions (H x L x W)
IP Code
Housing Material
Housing Colour
Cooling Concept
Operational Ambient Temperature
Storage Temperature
Operational Air Humidity
Galvanic Insulation
Remote Contact Switch-O
Overcurrent / Short Circuit
Overheating / Shut-Down
Polarity Protection
EN-LBC1224-40-G2MECHANICAL EN-LBC1224-60-G2
EN-LBC1224-40-G2INPUT & OUTPUT CONNECTION
PROTECTION
EN-LBC1224-60-G2
EN-LBC1224-40-G2 EN-LBC1224-60-G2
sales@enerdrive.com.au | Ph: 1300 851 535 | www.enerdrive.com.au
1* 10.5
10
9.5
11.25
11.5
11.5
11.8
12
12.5
16
15.4
15.8
15.2
32
30.8
31.6
31.4
10.5
11.5
11.5
13.25
13.8
12.8
12.8
12.8
13
13.2
20
19
22.5
23
23
23.6
24
25
21
12 21 24
23
23
26.5
27.6
25.6
25.6
25.6
26
26.4
2
11*
12
3
4
5
6
7
8
9
10
Programming Table
Position
Position
Threshold ThresholdReset Reset
Threshold ThresholdReset Reset
12V
Undervoltage
Overvoltage
24V
NOTES

This manual suits for next models

1

Popular Industrial Equipment manuals by other brands

dymax BlueWave 200 Operation manual

dymax

dymax BlueWave 200 Operation manual

Hayward HRSN4FS Series Installation, operation and maintenance instructions

Hayward

Hayward HRSN4FS Series Installation, operation and maintenance instructions

HBM Z6 Series operating manual

HBM

HBM Z6 Series operating manual

Fein Grit GX75 Series manual

Fein

Fein Grit GX75 Series manual

LNS QUICK LOAD SERVO S3 Startup manual

LNS

LNS QUICK LOAD SERVO S3 Startup manual

Imesa FLATWORK IRONER Installation and use instructions and warnings

Imesa

Imesa FLATWORK IRONER Installation and use instructions and warnings

ABB HT607894 Operation manual

ABB

ABB HT607894 Operation manual

PCB Piezotronics M353B12 Installation and operating manual

PCB Piezotronics

PCB Piezotronics M353B12 Installation and operating manual

HEIDELBERG Wallbox Safety instructions

HEIDELBERG

HEIDELBERG Wallbox Safety instructions

Rioned Andy Guest Jetters 2 Series Operator's manual

Rioned

Rioned Andy Guest Jetters 2 Series Operator's manual

Festool VAC SYS SE Original operating manual

Festool

Festool VAC SYS SE Original operating manual

altitude A2 Assembly instructions

altitude

altitude A2 Assembly instructions

Ametek dunkermotoren BG dCore Series Connection guide

Ametek

Ametek dunkermotoren BG dCore Series Connection guide

Belimo LM24A-MOD Technical data sheet

Belimo

Belimo LM24A-MOD Technical data sheet

Airxcel Aqua-Hot 600 Series installation manual

Airxcel

Airxcel Aqua-Hot 600 Series installation manual

SCHIEBEL LK Series Operation manual

SCHIEBEL

SCHIEBEL LK Series Operation manual

GMC HBB-0412 Operations & parts manual

GMC

GMC HBB-0412 Operations & parts manual

Festo MPS 8049013 Circuit diagrams

Festo

Festo MPS 8049013 Circuit diagrams

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.