BEFORE YOU BEGIN
ROUGH-IN
Please read these instructions carefully to familiarise yourself with the required tools, materials, and
installation sequences. Follow the sections that pertain to your particular installation. This will help you
avoid costly mistakes. In addition to proper installation, read all operating and safety instructions.
Prior to installation, inspect the cabinet and vanity top (either Durastone top, ceramic top or stone
quartz top) to ensure that no damage has occurred in transit. If damage has occurred, or a visible defect
exists, do not proceed with installation, and advise your supplier immediately.
Instructions, drawings, and diagrams contained in this manual present information available at the time
of printing.
Although every attempt has been made to keep them up-to-date, Englefield reserves the right to implement
product changes without further notice.
Floor Standing Models
Wall Hanging Models
850
800 467
605 755
650
600
905 1205 1205
www.englefield.co.nz
Page2
NOTE: For rough-in dimensions and installation instructions of the Valencia Elite Stone
vanity tops, please refer to the supplementrary guide supplied with the stone quartz tops.
1223207-A02-D October 2021
Please leave these instructions for the consumer. They contain important information.
INSTALLATION INSTRUCTIONS
VALENCIA
TM
Vanity

1 Drawer removal
Floor standing models must be fixed to a nog in the wall. Wall hung models must be fixed to two nogs
in the wall. The nog size should be 50 x 75mm.
(a) Open the drawer and carefully lift up on the
end of the drawer to release it from the runner
locator pins. It may be necessary to gently pry
the runner away from the drawer.
(b) The drawer is now only held by the runner
hooks at the back and can be pulled out in
the direction shown.
CONSTRUCTION REQUIREMENTS
INSTALLATION
TOOLS AND MATERIALS REQUIRED - (Not Supplied)
Floor standing models Wall Hung models
To suit pipework To suit screws
TOOLS MATERIALS - Not supplied & must be purchased separately
Fixing washers
20mm
Screws (Refer step 3)
10g x 75mm
50 50
Positioning of the nog near
vertical centre is recommended
however exact position will
depend on plumbing etc.
Locator pin
A height of 800 to 850mm
from the floor to the top of the
vanity top is recommended for
the wall hung vanity.
50mm from top of
cabinet to centre
of nog.
50mm from top of
cabinet to centre
of nog.
800-850
Runner hook
www.englefield.co.nz
Page3
1223207-A02-D October 2021
INSTALLATION INSTRUCTIONS
VALENCIA
TM
Vanity

Size Floor Mount
Number of screws required
600 3
750 4
Wall Mount
900 4
1200 5
5
7
7
9
Alternate drain
position for floor
standing models
3 Water supply and waste pipe holes
4 Fixing the vanity to the wall
(a) Measure and mark the centres for water
supply and waste pipes on the back of the
cabinet.
(c) Having drilled the required holes fit the cabinet
into position over the pipework.
(a) Fix the cabinet to the wall using screws (min
10g x 75mm) and *20mm washers. Screw
through the back rail or wall so that they screw
into the nog/s in the wall behind.
*Washers must be used to spread the load.
NOTE: Before fastening the cabinet make sure that
the it is sitting level and square and if installing a
floor mounted model ensure that the selected
location is free of bumps and protrusions.
NOTE: Screws should be positioned in an evenly
spaced pattern as shown below.
Floor standing models
Wall Hung models
Screw positions
for 600mm floor
mount vanity shown
Screw positions
for 600mm wall
mount vanity shown
50
50
50
50
NOTE: This section is only applicable if you have
purchased alternate trims for your vanity cabinet.
(c) Fix the new trims in place using the screws
that were removed from the original trims.
(b) Unscrew 3-4 screws from underneath each
trim and remove the trims from the cabinet.
NOTE: Keep the screws for use later on.
(a) After both drawers have been removed (refer to
section 1), unscrew the 2 trim fixing screws from
each angle bracket located behind either side of
each trim.
NOTE: Keep the screws for use later on.
2 Changing drawer trims (Optional)
Upper trim
Lower trim
Angle
brackets Angle
brackets
(b) With a suitably sized hole saw drill the holes
for the water supply and waste.
www.englefield.co.nz
Page4
1223207-A02-D October 2021
INSTALLATION INSTRUCTIONS
VALENCIA
TM
Vanity

(a) Unpack the top and check for any damage that
might have occured in transit. Check and
confirm the fit of your selected tapware.
(b) Apply a continuous bead of silicone (not
supplied) to the top edge of the cabinet sides
and back. Ensure there are no gaps in the
sealant bead. This will ensure the top stays
securely fitted to the cabinet and no water
spillage will find its way into the cabinet.
No silicone on
front edge
(a) To re-install the drawers, extend the runners.
Place a drawer onto the runners and slide back
so that the runner hooks insert into the rear of
the drawer.
(b) Make sure the locator pins line up with the
holes in the bottom of the drawer and press the
drawer down so that the pins slot into place.
= =
7 Drawer re-installation
Runner hook
Locator pin
6 Waste and tapware
(c) Place the vanity top onto the cabinet ensuring
that the back is flush against the wall and
there is an even overhang on either side of the
cabinet.
(d) Wipe off any excess sealant.
(a) Fit the waste and tapware. Connect the water
supply to the taps and waste pipe to the waste
outlet.
(b) Run hot and cold water and check for leaks.
When satisfied with the results move on to the
next section.
www.englefield.co.nz
5 Vanity top
Page5
INSTALLATION INSTRUCTIONS
VALENCIA
TM
Vanity
1223207-A02-D October 2021

8 Drawer Height Adjustment
Runner hook
www.englefield.co.nz
5 Vanity top
(a) Unpack the top and check for any damage that
might have occured in transit. Check and
confirm the fit of your selected tapware.
(b) Apply a continuous bead of silicone (not
supplied) to the top edge of the cabinet sides
and back. Ensure there are no gaps in the
sealant bead. This will ensure the top stays
securely fitted to the cabinet and no water
spillage will find its way into the cabinet.
No silicone on
front edge
(a) To re-install the drawers, extend the runners.
Place a drawer onto the runners and slide back
so that the runner hooks insert into the rear of
the drawer.
(b) Make sure the locator pins line up with the
holes in the bottom of the drawer and press the
drawer down so that the pins slot into place.
= =
7 Drawer re-installation
(a) All edges MUST be sealed with an approved
Silicone Sealant.
- Between cabinet and floor
- Bewteen cabinet and wall
- Between upstand and wall
8 Sealing
VALENCIA
TM
Vanity
6 Waste and tapware
(c) Place the vanity top onto the cabinet ensuring
that the back is flush against the wall and
there is an even overhang on either side of the
cabinet.
(d) Wipe off any excess sealant.
(a) Fit the waste and tapware. Connect the water
supply to the taps and waste pipe to the waste
outlet.
(b) Run hot and cold water and check for leaks.
When satisfied with the results move on to the
next section.
(a) All edges MUST be sealed with an approved
Silicone Sealant.
- Between cabinet and floor
- Bewteen cabinet and wall
- Between upstand and wall
9 Sealing
INSTALLATION COMPLETE
(a) Remove the drawer. To tilt the drawer front
forward before adjusting the height of drawer.
(b) Turn anticlockwise on the locator pin spacer
to raise the height of the drawer and turn clock-
wise to raise down. Repeat on the other runner.
Note: All drawers are aligned during assembly.
However further adjustment is often required
after installation.
Page6
INSTALLATION INSTRUCTIONS
VALENCIA
TM
Vanity
Height Adjustment Front Sectional
View
UP DOWN
1223207-A02-D October 2021

CONTACT AND WARRANTY INFORMATION
INSTALLATION INSTRUCTIONS
VALENCIA
TM
Vanity
CLEANING AND MAINTENANCE INSTRUCTIONS
- Please refer to the Owner’s Information Leaflet for contact information.
For cleaning instructions, please refer to the Owner’s Information Leaflet.
www.englefield.co.nz
(a) To re-install the drawers, extend the runners.
Place a drawer onto the runners and slide back
so that the runner hooks insert into the rear of
the drawer.
(b) Make sure the locator pins line up with the
holes in the bottom of the drawer and press the
drawer down so that the pins slot into place.
7 Drawer re-installation
(a) All edges MUST be sealed with an approved
Silicone Sealant.
- Between cabinet and floor
- Bewteen cabinet and wall
- Between upstand and wall
8 Sealing
INSTALLATION COMPLETE
Runner hook
Locator pin
INSTALLATION INSTRUCTIONS
ENGLEFIELD
NEW ZEALAND
KOHLER NZ LTD
Free Ph: 0800 100 382
Free Fax: 0800 664 488
AUSTRALIA
KOHLER AUSTRALIA
Free Ph: 1 800 ENGLEFIELD
(1 800 364 533)
www.englefield.com www.englefield.co.nz
For warranty information, please visit our website.
Table of contents
Other Englefield Indoor Furnishing manuals
Popular Indoor Furnishing manuals by other brands

Regency
Regency LWMS3015 Assembly instructions

Furniture of America
Furniture of America CM7751C Assembly instructions

Safavieh Furniture
Safavieh Furniture Estella CNS5731 manual

PLACES OF STYLE
PLACES OF STYLE Ovalfuss Assembly instruction

Trasman
Trasman 1138 Bo1 Assembly manual

Costway
Costway JV10856 manual