V07 - 30.09.2019 - be - G: mp, je - TS_EoNr_PAN-1_Bedienungsanleitung.cdr
Operating PAN-1.xxxxmanual
Front View
Status temperature steps 1 and 2
Status level steps 3 and 4
Temperature unit
Temperature display
Controller operat ion manual
Switching on:
page 1
1
2
3
4
5
6
7
1
2
3
4
5
6
7
Level display
Level unit
Operating elements
After power-up PAN-1, device prints „PAN“, Version and last 4 digits of its
ordernumber***. After that actual values will be displayed.
· View parameters
· set parameters
·scrolling or change value with ▲ and ▼
·adjustment with E
Menue-stages
Operation-button:

V07 - 30.09.2019 - be - G: mp, je - TS_EoNr_PAN-1_Bedienungsanleitung.cdr
Parameter Overview
page 2
S. e. t . . Access to parameter setting
S. P. . x. Switching point for chanal x.
r . P. . x. Reset point for chanal x.
o. u. t . x. Output switching behaviour for Kanal 1-4.
H. . n . o. Output hysteresis n.o. contact.
H. . n . c. Output hysteresis n.c. contact.
F. . n . o. Output window n.o. contact.
F. . n . c. Output window n.c. contact.
** L. . n . o. Output waterdetection n.o. contact.
Output waterdetection n.c. contact. ** L. . n . c.
Extended functionsE. F. . .
U. n . . t. Temperature units (°C or °F)
U. n . . L. Level units (mm or inch)
F. o . . x. Output switching behaviour step x in case of error
n . o. Output n.o. contact
n . c. Output n.c. contact
* S. n . . x. Current source, span
* O. F. . x. Current source, offset value
Virtual Zero point value for level (immersion depth) n. P. . .
E. n. d . . End parameter setting
* only PAN-1 with option „current source“
** only PAN-1 with option „water detection“
*** not applicable to PAN-1 with „water detection“

V07 - 30.09.2019 - be - G: mp, je - TS_EoNr_PAN-1_Bedienungsanleitung.cdr
Menu structure
page 3
Extended functions
Main parameters
Set
Access parameter setting
E
temperature unit
End parameter setting
Zero point, level
Span and Offset for 4..20mA
current source „level“
Span and Offset for 4..20mA current
source „temperature“
status in error condition
level unit
End
nP
OF 2*
Sn 2*
OF 1*
Sn 1*
Fo 4
Fo 3
Un t
Fo 2
Fo 1
Un L
End parameter setting
Extended functions
Reset point step 1
End
EF
out 2
r P 2
SP 2
out 1
r P 1
SP 1
Switching behaviour
Switching point
Reset point step 2
Switching behaviour
Switching point
out 3
r P 3
SP 3
Reset point step 3
Switching behaviour
Switching point
out 4
r P 4
SP 4
Reset point step 4
Switching behaviour
Switching point
„E“ 2 sec
Yes
No
▲
▼

V07 - 30.09.2019 - be - G: mp, je - TS_EoNr_PAN-1_Bedienungsanleitung.cdr
Display of the first parameter value “SP 1”
Scroll through parameter list forwards / backwards
Continuous key activation: The parameter list scrolls
automatically forwards
To key▼:
By scrolling back to the first parameter, the actual value
display is changed by using key ▼.
Lastest 5 seconds after pressing the last key, the system
changes to the actual value display.
Display “ S E T“
After 5 seconds, the system changes to the actual value
display
Display of the first parameter value “SP 1 “
If no key is actuated within 2 minutes, the system changes to
the actual value display without saving.
Scroll forwards through the parameter list
Continuous activation of keys: The parameter list
scrolls automatically to the end (End).
View parameters
Condition:
Operating mode
Actual value display
1.
Key ▲
2.
Key ▲/▼
3.
Back to actual
value display
Key E or Key▼
Setting the main
parameters
Condition:
Operating mode
Actual value display
1.
Key E
>press for 2 secs
2.
Key E
Latest 5 sec after „SET“
3.
Keys▲
page 4

V07 - 30.09.2019 - be - G: mp, je - TS_EoNr_PAN-1_Bedienungsanleitung.cdr
Scroll forwards / backwards through the parameter list.
Set the value using key▲ + or ▼ –
If the value is out of range, the limit is automatically specified.
The next decimal place blinks
Parameter list forward until EF.
Un t Select temperature unit °C or °F
Un t Unit °C or °F blinks
4.
With the▲/▼ keys
Selection with
key E
5.
Keys▲/▼
6.
Confirmation of the
set value
Key E
7.
Repeat points 5 and 6
Setting extended
functions EF
8.
Keys▲
9.
Key E
10.
Key E
Right-hand decimal place blinks at numerical values
function blinks, e.g. H nc, when parameter out.
No decimal place is blinking
The set value is being checked with its countervalue for
plausibility. If an error occurs, the new value will be rejected
and the last valid value restored.
page 5

V07 - 30.09.2019 - be - G: mp, je - TS_EoNr_PAN-1_Bedienungsanleitung.cdr page 6
Select unit °C or °F
11.
Keys ▲/▼
12.
Key E Selected unit is displayed
Using the keys ▲ / ▼
Additional functions (see menu structure) can be accessed in the extended menu. To set the
functions, proceed as described under point 9 to point 12.
Scroll forwards through parameter list as far as “E n d”.
(In main parameters and extended functions)
Continuous activation of key: the parameter list scrolls
automatically to end (End).
Key ▲
12.
Key E
Actual value display
Malfunction
Temperature actual value display indicates "Err" and the status
LED's 1 + 2 blinks. The temperature outputs will be set in accordance
with Fo 1 + Fo 2. The temperature power source will be set to value
<=3,6 mA.
Level actual value display of indicates “Err” and the status LED's 3 + 4
blink. The level outputs will be set in accordance with Fo 3 + Fo 4. The
level power source gets adjusted to the value <=3,6 mA.
The output gets deactivated and the appropriate status LED blinks.
Cyclical examination whether the short-circuit is eliminated.
Temperature sensor:
Level senor:
Output short circuit:
Table of contents
Popular Measuring Instrument manuals by other brands

PCB Piezotronics
PCB Piezotronics J356A43 Installation and operating manual

Rice Lake
Rice Lake 480 Legend Series Operation manual

ABB
ABB ProcessMaster FEP630 series Operating instruction

Foss
Foss NIRS DA1650 user manual

Chauvin Arnoux
Chauvin Arnoux AEMC AmpFlex user manual

XS Instruments
XS Instruments Temp70 PT100 vio instruction manual