SILENT MV - 160/100
SILENT MV - 160/100 T
INSTALLATION AND WIRING INSTRUCTIONS
SILENT MV 160/100 – SILENT MV 160/100 “T”
Installation and wiring instructions for in-line duct fan.
The SILENT MV 160/100 / SILENT MV 160/100 “T” in-line duct extractor fans have been manufactured in
accordance with the rigorous standards of production and quality control lay down by the international
Quality Standard ISO 9001. All components have been checked and each of the finished products has
been tested at the end of the manufacturing process.
We recommend that you check the following when receiving this product:
• That it is the correct size and model.
• That the details on the rating label are those you require; voltage, frequency, performance.
Important Safety Information
• The installation should always be carried out in accordance with all current applicable Standards
to the country in which the product is installed.
• The installation should always be carried out by a suitably qualified and competent person (s).
• These fans are not for stand-alone use. They are designed to be incorporated in to ducted systems,
machines or where safe operation has been ensured by providing protection to moving parts.
• Do not use this product in, or to extract from, potentially hazardous or explosive atmospheres.
• If the extractor operates in a room with a boiler or any other type of appliance requiring air for
combustion, check that air replacement in lets are sufficiently sized.
• The extractor outlet must not be connected to a duct used to exhaust smoke or fumes from any
appliance that uses gas or any other type of fuel.
Installation
• This unit must not be installed outside, unless covered by a suitable weather proof enclosure.
• For installation a support bracket is provided with the extractor which allows the motor and
impeller assembly to be fitted or removed without dismantling the adjacent ducting.
• For installation, remove the motor and impeller assembly from its support bracket (Fig. 1).
• Fix the support bracket in position where the extractor is to be located.
• Connect the inlet and outlet ducting. In order to avoid losses in performance we do not recommend
that fan is used in conjunction with ducting of a lesser diameter that the fan connection spigots.
If the extractor is connected to flexible ducting, then the ducting must be expanded as much as
possible.
• The fan should be installed to ensure minimum vibration and noise transmission to surrounding
ductwork and building frames. Ant vibration mountings and sound attenuating accessories are
available. Please contact your local distributor.
• The fan should always be installed so that safe operation and maintenance can be ensured.
• Before installing the unit ensures the impeller is running freely and there are no obstructions to
the airflow.
Electrical Connection
• Before Installation and Wiring ENSURE THE MAINS ELECTRICAL SUPPLY IS DISCONNECTED!
• The electrical installation must include a double pole switch with a contact clearance or at least
3mm, correctly sized and in accordance with the electrical standards of the country of installation.
• Ensure that the voltage and frequency of the electrical supply match the information stated on the
Date Plate of the unit (maximum recommended tolerance of Voltage (V) and Frequency (Hz) ±5%).
• The SILENT MV 160/100 standard fan (non-Timer) is fitted with single-phase 2-speed motor. For
connection using the two speed selection switches REGUL-2 or COM-2, follow wiring diagrams (Fig.
2). All motors are also 100% speed controllable via electronic voltage regulating speed controllers.
For connection using a REB single phase speed controlled, follow wiring diagrams (Fig. 3).
• The SILENT MV 160/100 “T” fan is fitted with single-phase 1 –speed motor and an electronic timer
adjustable from approx. 1 minute up to 30 minutes. For connection, follow wiring diagram (Fig. 4).
• Before operation, check all connections are correct and there are no obstructions to the airflow.
• On connecting the electrical supplies ensure the direction of rotation and airflow corresponds with
the direction airflow / rotation arrows (sited on unit).
Maintenance
• Before inspection or repair, ensure that the unit is disconnected from the mains electrical supply.
• The fan impeller should be cleaned at least once (1) a year to ensure trouble free operation.
• Do not clean the unit with strong detergents or cleaning fluids. Use a damp (not wet) cloth only
for cleaning.
After Sales Services
We recommend you do not dismantle or remove any other parts than those mentioned, as any
tampering would automatically cancel the guarantee. If you detect any fault, contact EnviroVent on
01423810810.
EnviroVent reserves the right to alter specifications without notice.
All EnviroVent products are designed to be recycled when they reach the end of their working life. To
save the environment and to reduce land fill, please call EnviroVent on 01423810810 to arrange for the
fan to be returned to the factory.
Guarantee
The SILENT MV-160/100 fans are covered by a five year guarantee, subject to the
specified maintenance stated within this booklet. In the event of any failure of the
fan within five years of supply- excluding only wilful or careless damage – we will
exchange the fan free of charge.
Name and Address of Purchaser:
Model:
Date of Purchase:
Dealer Stamp:
EnviroVent Limited
EnviroVent House
Hornbeam Business Park
Harrogate
HG2 8PA
T / 01423 810 810
E / info@envirovent.com
W / envirovent.com
9023004002-02
Leading Manufacturer & Supplier of
Innovative & Sustainable Ventilation Systems

This manual suits for next models

1

Other Envirovent Fan manuals

Envirovent ECO DMEV User manual

Envirovent

Envirovent ECO DMEV User manual

Envirovent ECO dMEV LC Manual

Envirovent

Envirovent ECO dMEV LC Manual

Envirovent Slimline 150 Quick start guide

Envirovent

Envirovent Slimline 150 Quick start guide

Envirovent energiSava 200 User manual

Envirovent

Envirovent energiSava 200 User manual

Envirovent MEV SPIDER User manual

Envirovent

Envirovent MEV SPIDER User manual

Envirovent fliterless infinity fan 230v User manual

Envirovent

Envirovent fliterless infinity fan 230v User manual

Envirovent filterless extractor fan User manual

Envirovent

Envirovent filterless extractor fan User manual

Envirovent CLASSIC-100 Manual

Envirovent

Envirovent CLASSIC-100 Manual

Envirovent SABIK 350 User manual

Envirovent

Envirovent SABIK 350 User manual

Envirovent PIV User manual

Envirovent

Envirovent PIV User manual

Envirovent fliterless infinity fan 230v Quick start guide

Envirovent

Envirovent fliterless infinity fan 230v Quick start guide

Envirovent PROFILE-100 Assembly instructions

Envirovent

Envirovent PROFILE-100 Assembly instructions

Envirovent energiSava 250 User manual

Envirovent

Envirovent energiSava 250 User manual

Envirovent OZEO User manual

Envirovent

Envirovent OZEO User manual

Envirovent PIV AIR SOURCE User manual

Envirovent

Envirovent PIV AIR SOURCE User manual

Envirovent MEV SPIDER User manual

Envirovent

Envirovent MEV SPIDER User manual

Envirovent kudos Manual

Envirovent

Envirovent kudos Manual

Envirovent SILENT Manual

Envirovent

Envirovent SILENT Manual

Envirovent SLIMLINE 300 Quick start guide

Envirovent

Envirovent SLIMLINE 300 Quick start guide

Envirovent energisava250 User manual

Envirovent

Envirovent energisava250 User manual

Envirovent MEV 160 User manual

Envirovent

Envirovent MEV 160 User manual

Envirovent Damp Pro DP-EVL User manual

Envirovent

Envirovent Damp Pro DP-EVL User manual

Envirovent PROFILE–150S Assembly instructions

Envirovent

Envirovent PROFILE–150S Assembly instructions

Envirovent ECO DMEV+ LC User manual

Envirovent

Envirovent ECO DMEV+ LC User manual

Popular Fan manuals by other brands

Modern Forms F-WC-WT installation instructions

Modern Forms

Modern Forms F-WC-WT installation instructions

GUTFELS VB 37058 ch instruction manual

GUTFELS

GUTFELS VB 37058 ch instruction manual

Bayside LAGOON manual

Bayside

Bayside LAGOON manual

S&P TDM-200 User instruction

S&P

S&P TDM-200 User instruction

Teral CTFII instruction manual

Teral

Teral CTFII instruction manual

AEREX Reco-Boxx 750 ZXR Operation and maintenance instructions

AEREX

AEREX Reco-Boxx 750 ZXR Operation and maintenance instructions

Arbonia TECNA manual

Arbonia

Arbonia TECNA manual

Mitsubishi Electric Lossnay LGH-150RVXT-E operating instructions

Mitsubishi Electric

Mitsubishi Electric Lossnay LGH-150RVXT-E operating instructions

KLASS Fan SIROCCO user manual

KLASS Fan

KLASS Fan SIROCCO user manual

BLAUBERG VENTO Expert A50-1 W Operation manual

BLAUBERG

BLAUBERG VENTO Expert A50-1 W Operation manual

Casablanca CEILING FAN Installation and operation manual

Casablanca

Casablanca CEILING FAN Installation and operation manual

Casablanca M6020-01 user manual

Casablanca

Casablanca M6020-01 user manual

Alpha Fan AX20-5B/56 instruction manual

Alpha Fan

Alpha Fan AX20-5B/56 instruction manual

Commercial Electric HVFF 20CE Use and care guide

Commercial Electric

Commercial Electric HVFF 20CE Use and care guide

Flex-a-Lite 675 installation instructions

Flex-a-Lite

Flex-a-Lite 675 installation instructions

Hunter 25109 Manual de Installatión y Operatión

Hunter

Hunter 25109 Manual de Installatión y Operatión

Craftmade Monaghan MGN52AO installation guide

Craftmade

Craftmade Monaghan MGN52AO installation guide

Kendal Lighting AC-20244 installation instructions

Kendal Lighting

Kendal Lighting AC-20244 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.