TECHNICAL DATA
BA_EE150 // v1.2 // Modification rights reserved
The EE150 is ready to use and does not require any conguration by the user. The factory setup of EE150 corresponds to the type num-
ber ordered. For ordering guide please see data sheet at www.epluse.com/ee150.
If needed, the user can change the factory setup by using the optional E+E Product Configuration Adapter (EE-PCA) and the E+E
Product Configuration Software (EE-PCS). With these one can set the output scaling, and perform one or two point adjustment for
humidity and temperature.
For product data sheet EE-PCA please see www.epluse.com.
The E+E Product Configuration Software (EE-PCS) is free and can be downloaded from www.epluse.com/configurator.
SETUP AND ADJUSTMENT
USA
FCC notice:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate ra-
dio frequency energy and, if not installed and used in accordance with the installation manual, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit dierent from that to which thereceiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
CANADIAN
ICES-003 Issue 5:
CAN ICES-3 B / NMB-3 B
Langwiesen 7 • 4209 Engerwitzdorf • Austria
Tel: +43 7235 605-0 • Fax: +43 7235 605-8
LG Linz Fn 165761 t • VAT No ATU44043101
Place of Jurisdiction: 4020 Linz • DVR0962759
Measurands
Relative Humidity
Working range 10...90 % RH
Accuracy at 20 °C ±3 % RH (30...70 % RH), otherwise ±5 % RH
Temperature dependency, typ. ±0.03 % RH/°C
Temperature
Working range -5...55 °C (23...131 °F)
T-Accuracy at 20 °C ±0.3 °C
Outputs
Analog output 0 - 10 V RL≥ 10 kΩ
(0...100 % RH; T: see ordering guide) 4 - 20 mA (2-wire) RL≤ 500 Ω
General
Power supply (Class III) (EU) / class 2 (NA)1)
for 0 - 10 V 15 - 35 V DC or 24 V AC ±20 %
for 4 - 20 mA 10 V + RL x 20 mA < UV< 35 V DC
Current consumption, typ. DC supply: 5 mA
AC supply: 13 mArms
Connection Screw terminals, max. 1.5 mm2
Enclosure material Polycarbonate, UL94 V-0 approved
Protection rating IP65 / NEMA 4X
Cable gland M16 x 1.5 / UL94 V-2
Sensor protection PTFE filter, non-removable
Electromagnetic compatibility EN 61326-1 EN 61326-2-3
Industrial Environment
FCC Part 15 Class B ICES-003 Class B
Working temperature range -5...55 °C (23...131 °F) 0...95 % RH, non-condensing
Storage temperature range -25...60 °C (-13...140 °F) 20...80 % RH
1) USA & Canada class 2 supply required, max. supply voltage 30 V DC.